Parameter
Min
Max
Resolution
Comment
Waveform High*
-20 V
+20 V
10 mV
10 V (nominal)
Range = 0 to 200%
Waveform Null**
-20 V
+20 V
10 mV
0 V (nominal)
Waveform Low*
-20 V
+20 V
10 mV
-10 V (nominal)
Range = 0 to 200%
Common-mode
Bias
+
-10 V
+10 V
5 mV
0 V (nominal)
Rise/Fall Time
(High speed)
1 µs
4 µs
100 ns
Slew rate limit: 40 V/µs
Rise/Fall Time
(Low speed)
1 µs
39 µs
100 ns
Slew rate limit: 40 V/µs
* Differential. ** Differential and must be between the waveform high and low.
+
The common-mode bias is available on revision D or higher parametric 429 modules. The
common-mode bias voltage cannot be set in a way that causes either side of signal to be
outside the -10 V to +10 V range.
Table 6.7—ARINC 429 Parametric Waveform Characteristics
6.3.2 Configurable Frequency
You can operate parametric ARINC 429 modules at non-standard speeds. This
configurable frequency can be set in software for each transmit and receive chan-
nel. Thus, 429 channels may be used with equipment that varies from the ARINC
429 standard (such as some implementations of ARINC 575).
Use a bit-rate configuration function to get a non-standard frequency. Contact
Customer Support (see Section 1.5) for the appropriate parameters for your module
part number and desired frequency.
6.3.3 Output State
ARINC 429 modules with output state functionality have the capability under
software control to:
•
Open either output leg of a transmit channel
•
Short either output leg of a transmit channel to ground
Summary of Contents for OMNIBUS II NI PXIe
Page 3: ......
Page 15: ...INTRODUCTION 1 6 OmniBus II NI PXIe User Manual This page intentionally blank...
Page 19: ...INSTALLATION 2 4 OmniBus II NI PXIe User Manual This page intentionally blank...
Page 47: ...MODULE CONFIGURATIONS 6 8 OmniBus II NI PXIe User Manual This page intentionally blank...
Page 55: ...CONNECTOR PINOUTS 7 8 OmniBus II NI PXIe User Manual This page intentionally blank...
Page 59: ...COUPLING AND TERMINATION A 4 OmniBus II NI PXIe User Manual This page intentionally blank...
Page 65: ...ERRATA SHEET C 2 OmniBus II PCIe PXIe User Manual This page intentionally blank...
Page 67: ...REVISION HISTORY D 2 OmniBus II NI PXIe User Manual This page intentionally blank...