8
X
X-8 twin
Operating instructions
Page 1: ...8 X X 8 twin Operating instructions 8 X X 8 twin Operating instructions ...
Page 2: ... all relevant EN standards Changes and printing errors reserved Version August 2005 Mounting bracket 2 Figures X 8 twin Base Unit without Cards Interlocking device power supply Slots 2 temperature regulated fans The X 8 is CE certified and complies with all relevant EN standards Changes and printing errors reserved Version August 2005 Mounting bracket ...
Page 3: ...lation location indoors The device can be fastened to the wall using the supplied mounting materials Must be observed Hazard and safety information 3 Figure of X 8 twin 2 1 Pictographs 3 2 Hazard and safety information 3 2 1 Installation instructions 3 2 2 Opening the housing 4 2 3 Potential equalization and grounding 5 3 Preparing the base unit 5 3 1 Mounting bracket 5 3 2 Changing thepower suppl...
Page 4: ...rder to prevent damage to the device 2 Hazard and safety information 2 Hazard and safety information Because of fire hazard due to lightening it is recommen ded that all mechanical parts e g V16 equipotential bus bars distributors etc are mounted on non combustible underlays Combustible materials include wooden beams wooden boards plastics etc 2 2 Opening the housing Before opening the housing Be ...
Page 5: ... dein stallation Fig 3 4 3 Preparing the base unit 3 Preparing the base unit Fig 1 Fig 2 Fig 3 Fig 4 2 3 Potential equalization and grounding The proper grounding and installation of the system must com ply with EN 50 083 Part 1 Thepowersupplymaybeoperatedonlyindevicesforwhichthe sepowersupplieshavebeenapprovedand duetohighdischar ge current only in power supply networks with a protected gro unded...
Page 6: ...splayed in line 3 ASTRO X 8 Version X XX 1 deutsch next X 8 Parameter Bus adress XXX TemperatureXX C When uninstalling it s best first to remove the plug in cards at slot 1 and slot 8 using the plug in card remo val tool To press out the power supply unit carriers the plug in card removal tool is alternately placed on the nuts on the side and pressed This releases the plug contacts of the power su...
Page 7: ...AT distribution board 5 Installing plug in cards 5 Installing plug in cards Fig 7 Fig 8 Fig 9 Fig 10 Single cards Plug in the card Connect the tuner connection cable of the tuner with the output of the SAT distributor which car ries the required polarization 5 2 5 3 Cards for terrestrial conversion Because the SAT distribution board is suitable exclusively for SAT intermediate frequencies 950 2150...
Page 8: ...n cards 7 level adjustment Fig 11 Lever of the card removal tool in position Fig 12 Level regulators 5 4 Uninstalling plug in cards After disconnecting the cable connections lift out the plug in cards with the supplied plug in card removal tool Place the lever between the card and the alumi num frame and press down This disconnects the plug contacts of the card from the mainboard Fig 11 IMPORTANT ...
Page 9: ... Not used loop through outputs must be terminated FUR 75 order no 610 770 8 SAT distribution board 9 8 Configuration SAT distribution board The SAT distribution board of the X 8 offers several possibilities of configuration The delivery state of the SAT distribution board looks as printed above that means 3x 1 input Eingang to 7 outputs Ausgang and 1x 1 input Eingang in 4 outputs Ausgang Please no...
Page 10: ...he upper splitter because a loop through via the outputs of each splitter causes a high attennuation 8 SAT distribution board 10 Additional configuration example The configuration example offers 1 x 1 input Eingang in 2 outputs Ausgang 1 x 1 input Eingang in 9 outputs Ausgang and 2 x 1 input Eingang in 7 outputs Ausgang Note Not used loop through outputs must be terminated Changes in the configura...
Page 11: ... X A V quad VCP Adapter Cable Adapter cable for connecting X AV cards X 8 twin Basis VCP 14 VCP 15 2 9 Technical specifications and accessories 11 Technical changes reserved technical specifications X 8 twin SAT processing base unit without cards XF internal jumper cable XF 450 X 8 Base unit Supply voltage V Hz 230 50 EMC EN 50083 Pt 2 A1 compliant Permitted ambient temp C 0 50 Housing H x W x D m...
Page 12: ... temp C 15 50 KC 3 external programming unit for programming all setting parameters order no 330 650 Accessories 12 X BC Buscontroller X BC 1 The headend bus controller is for centrally setting all bus capable headend devices via PC Maintenance and re programming of already set up headends can be done via modem Operation is only possible with the HE programming software Control of up to 240 bus ca...
Page 13: ...he failed module to the redundancy module activating HF the redundancy module HE Programmiersoftware Accessories 13 The HE programming software order no 330 630 facilitates programming X 5 X 8 V16 headend systems with a PC or laptop computer The user can store all headend parameters in the office prior to commissioning for example received satellite SAT programs output channel program video and au...
Page 14: ...m So the configuration of many programs is perfectly possible during several sec onds Accessories 14 With the HE programming software up to twenty X 5 X 8 V16 headend devices can be saved in a configura tion file From the menu item Display unit the user has the option of accessing the program parameters of an already existing headend and can then easily edit and modify Current program satellite as...
Page 15: ...Notes Notes 15 Notes Notes 15 ...
Page 16: ...ch Gladbach Bensberg Tel 0 22 04 405 0 Fax 0 22 04 405 10 http www astro kom de 82 275 450 August 05 ASTRO Strobel Kommunikationssysteme GmbH Olefant 1 3 D 51427 Bergisch Gladbach Bensberg Tel 0 22 04 405 0 Fax 0 22 04 405 10 http www astro kom de 82 275 450 August 05 ...