Chapter 2 INDIVIDUAL FORMATS FOR VG CONTROL COMMANDS
157
2.80
LID14 [20H 72H]: ID1 data acquisition
Function:
This command gets the ID1 data of the designated program number. When
the program has any number from 1001 to 2000, the command reads out
from the fixed data. When the program number is 9999, the command
reads the data from the command work RAM.
Sequence: Type 3
Parameters:
STX
1 byte
02H
VG4CMD
1 byte
FDH
LID14
2 bytes
20H 72H
Program number
1 to 4 bytes
“0” to “2000”, “9999”
ETX
1 byte
03H
Fig. 2-80-1
Data:
STX
1 byte
02H
TRDT
1 byte
10H
Aspect
1 byte
“0” = 4:3 Normal
“1” = 16:9 Normal
“2” = 4:3 LB
“3” = Not Defined
ETX
1 byte
03H
Fig. 2-80-2