Astria Vega32ZP2 Installation And Operation Instruction Manual Download Page 1

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

 WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for 

the minimum fireplace size requirement.
Do not install the appliance in this firebox, unless this firebox meets the minimum dimensions required for 

the installation.

 

WARNING: For use only with a listed, gas-fired unvented decorative room heater not to exceed 40,000 

Btu/H.
Do not build a wood fire.

 

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

 

 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance.

 

 WHAT TO DO IF YOU SMELL GAS: 

• 

 Do not try to light any appliance. 

• 

 Do not touch any electrical switch; do not use any phone in your building. 

• 

 Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

• 

If you cannot reach your gas supplier, call the fire department.

 

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Installation and Operation Instructions

Astria

TM

 Unvented (Vent-Free) Universal Firebox

P/N 126694-01   Rev.B   03/2014

PFS

®

US

Models

Vega32ZP2

Vega36ZP2
Vega36ZP3

Vega42ZP2
Vega42ZP3

P126694-01

Summary of Contents for Vega32ZP2

Page 1: ...losion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO I...

Page 2: ...rying to assemble operate or service this heater Improper use of this fireplace can cause serious injury or death from burns fire explo sion electricalshockandcarbon monoxide poisoning WARNING Any cha...

Page 3: ...or stored under dusty conditions 6 Do not use this firebox to cook food or burn paper or other objects 7 Turn firebox off and let cool before servic ing Only a qualified service person should service...

Page 4: ...not affect the performance of the fireplace or vent free gas logs OPTIONAL FIBER AND PORCELAIN LINERS For a vintage look the fiber panels give a old masonry brick look and are light weight and easy to...

Page 5: ...0 7 610 10 517 3 518 3 282 8 152 6 866 13 119 8 132 3 522 8 152 10 457 23 919 12 564 16 586 19 461 4 366 6 039 22 444 PRODUCT SPECIFICATIONS Figure 1 Product Specifications 32 Models Right Side View L...

Page 6: ...074 7 049 20 962 8 063 7 410 8 513 11 492 3 277 2 550 8 175 8 525 8 331 8 175 13 892 10 349 24 934 21 081 6 043 29 101 26 366 40 250 Right Side View Left Side View Front View Firebox Top View 36 MODE...

Page 7: ...23 964 22 281 3 120 44 253 7 564 10 532 13 369 2 520 8 153 3 265 10 768 10 436 2 523 8 153 14 233 12 582 50 045 23 216 4 479 6 028 36 143 27 117 Right Side View Left Side View Front View Firebox Top V...

Page 8: ...ting directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the un confined space Adjoining rooms are communicating only if th...

Page 9: ...outdoors and vents to the outdoors Example Gas water heater __________ Btu Hr Vent free heater _________ Btu Hr Total _________ Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued 4 Compare the maxim...

Page 10: ...required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the attic will ac...

Page 11: ...m the wall This com bustible material must be 4 from the side of the fireplace cabinet see Figure 6 B Clearances from the top of firebox opening to ceiling should not be less than 42 C When firebox is...

Page 12: ...Inside Height Figure 8a Figure 8b Figure 8c Figure 8d NOTICE Ifyourinstallationdoes not meet the minimum clear ances shown you must do one of the following raise the mantel to an accept able height r...

Page 13: ...ebox front facing WARNING Do not allow any combustiblematerialstooverlap the firebox front facing INSTALLATION Continued Figure 9 Attaching Firebox to Wall Studs Model May Vary From Illustration Naili...

Page 14: ...damage the firebrick concrete insert Figure 11 Location of Knockout for Gas Line Knockout Chisel Firebrick Side Wall Remove this Area Side View INSTALLING OPTIONAL BLOWER ACCESSORIES NOTICE The firebo...

Page 15: ...hich way you intend to gain access into the bottom rear of the firebox to install the blower accessory The lower front panel can be removed easily by snapping out the front with a flat blade screwdriv...

Page 16: ...e sure wire routing is not pinched or in a precarious position Correct accordingly INSTALLATION Continued Model BK Installation 1 Be certain that all wire terminals are securely attached to terminals...

Page 17: ...r operation Turn blower off by turning knob fully coun terclockwise before continuing 9 Peel off backing paper and stick supplied wiring diagram decal on firebox bottom approximately 12 in front of bl...

Page 18: ...operation Turn blower off before continuing 8 Peel off backing paper and stick supplied wiring diagram decal on firebox bottom approximately 12 in from of blower see Figure 18 page 17 9 Replace all pa...

Page 19: ...s accessed through a vented crawl space AK4F or through a sidewall AK4 See Figure 21 CAUTION Combustion air inlet ducts shall not terminate in attic space Figure 21 Outside Air Kit Secure to Collars w...

Page 20: ...t side of firebox and fasten using remaining Phillips screw LOCATING ACCESS COVER PLATE Sheet metal cover plates located underneath front hearth refractory if included may have shifted or moved out of...

Page 21: ...at 1 800 655 2008 When calling have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the f...

Page 22: ...it provide additional air to reduce build up of condensation that occurs in today s tightly constructed homes AK4F Outside Air Kit for Floor Installation AK4X Collar and Hood accepts any length of 4 f...

Page 23: ...tain Classic C32GO 32 Oak Stain Georgian 36 WALL MANTELS W36TU 36 Unfinished Traditional W36TO 36 Oak Stain Traditional 36 CORNER MANTELS C36TU 36 Unfinished Traditional C36TO 36 Oak Stain Traditional...

Page 24: ...www Astria US com 126694 01B 24 1 2 3 4 5 6 7 8 PARTS MODELS 32 36 AND 42...

Page 25: ...403 Flush Face 42 VF Firebox White Stacked Brick VEGA42ZP2 F0404 Louver Face 42 VF Firebox White Stacked Brick VEGA42ZP2 F0405 Flush Face 42 VF Firebox Red Stacked Brick VEGA42ZP2 F0406 Louver Face 42...

Page 26: ...www Astria US com 126694 01B 26 1 2 3 4 5 6 6 PARTS MODELS Vega32ZP2 Vega36ZP2 Vega36ZP3 Vega42ZP2 and Vega42ZP3...

Page 27: ...Red Stack 1 125286 02 Right Refractory Red Herringbone 1 125296 02 Right Refractory Red Herringbone 1 3 108430 01 Rear Refractory White Stack 1 125282 01 Rear Refractory White Stack 1 125292 01 Rear R...

Page 28: ...ted on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ Keep recei...

Page 29: ...flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use...

Page 30: ...NOTES 30...

Page 31: ...NOTES 31...

Page 32: ...notice in design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126694 01...