Astria Plantation48M3 F0691 Installation And Operation Instructions Manual Download Page 6

www.Astria.US.com

126634-01A

6

Figure 6 - Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION GAIN (IN)

48" Plantation

Fireplace

66 

1

/

2

"

12-12DM

12-12HT

Pipe Section

10 

5

/

8

"

18-12DM

18-12HT

Pipe Section

16 

5

/

8

"

24-12DM

24-12HT

Pipe Section

23 

5

/

8

"

36-12DM

36-12HT

Pipe Section

34 

5

/

8

"

48-12DM

48-12HT

Pipe Section

46 

5

/

8

"

RLT-12D

RLT-12HT

Round 

Termination

3

/

4

"

*

STL-12D

Square Chase-

Top with Slip 

Section

7"

 to 15

"

*

* The lineal gain for the terminations is mea

-

sured to the flue gas outlet height.

Hemmed 

End

12 

3

/

8

Stainless 

Inner Pipe

15" Galvanized 

Outer Pipe

ASSEMBLY AND INSTALLATION OF 

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of 

a galvanized outer pipe, a stainless steel in

-

ner flue pipe and a wire spacer. Pipe sections 

must be assembled independently as chimney 

is installed. When connecting chimney directly 

to fireplace, inner flue pipe section must be 

installed first with lanced side up. Outer pipe 

section can then be installed over flue pipe 

section  with  hemmed  end  up.  Press  down 

on  each  pipe  section  until  lances  securely 

engage  hem  on  fireplace  starter.  Wire  will 

assure  proper  spacing  between  inner  and 

outer pipe sections.

Continue to assemble chimney sections as 

outlined above, making sure both inner and 

outer pipe sections are locked together. When 

installing double wall snap-lock chimney to

-

gether, it is important to assure joint between 

chimney sections is locked. Check by pulling 

chimney upward after locking. Chimney will 

not  come  apart  if  properly  locked.  It  is  not 

necessary  to  add  screws  to  keep  chimney 

together (exception, see Figure 9, page 8).

Figure 5 - Outside Air Kit

Secure to Collars with Metal Tape, Screws 

or Straps (Min. of 1/4" x 20" in size)

Air Inlet 

Location 

Must Allow 

For Bushes 

or Snow

Vent Hood 

Required for 

Wall Installation

Air Inlet 

Eyebrow

Vented Crawl Space

(Check Local Codes 

Before Installing in a 

Vented Crawl Space)

 CAUTION: Combustion air 

inlet ducts shall not terminate 

in attic space.

The  maximum  height  for  the 

air vent can not exceed 3 feet 

below the flue gas outlet of the 

termination.

CHIMNEY PIPE

INNOVATIVE HEARTH PRODUCTS chimney 

system consists of 12", 18", 24", 36"' and 48" 

snap-lock, double-wall pipe segments, planned 

for  maximum  adaptability  to  individual  site 

requirements. Actual lengths gained after fit

-

ting overlaps must be taken into consideration 

(lineal gain) and are given in lineal gain chart 

(see Figure 6). Lineal gain is the actual mea

-

surable length of a part after two or more parts 

are connected. For Canada, use chimney parts 

designated "HT".

 WARNING: The opening in the 

collar around the chimney at the 

top  of  the  fireplace  must  not  be 

obstructed. Never use blown insula-

tion to fill the chimney enclosure.

INSTALLATION

Continued

Summary of Contents for Plantation48M3 F0691

Page 1: ...with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used WARNING If the information in these instructions is not fol...

Page 2: ...actured or approved by INNOVATIVE HEARTH PRODUCTS in combination with a IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace C...

Page 3: ...Straps Provided Hearth Spacer Required for Combustible Floor 0 to Bottom 12 Min Each Side Hearth Extension 72 X 20 Outside Air Access Location 1 5 Airspace Back and Sides 2 Chimney Airspace Clearance...

Page 4: ...at the level of the flue gas outlet see Figure 15 page 9 FRAMING 1 Frame the opening for the fireplace using the dimensions shown in Figures 1 and 2 2 If the fireplace is to be installed directly on c...

Page 5: ...al Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension MANTELS A mantel may be installed if desired see...

Page 6: ...ctions are locked together When installing double wall snap lock chimney to gether it is important to assure joint between chimney sections is locked Check by pulling chimney upward after locking Chim...

Page 7: ...24 36 48 4 3 8 16 3 8 ELBOW SET ONLY 9 3 4 25 1 2 1 12 3 4 30 3 4 1 15 34 3 4 1 18 40 1 1 21 1 4 46 1 4 1 23 3 4 49 1 4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1...

Page 8: ...ROOF To maintain a 2 clearance to pipe on roof with a pitch a rectangular opening must be cut 1 Determine center point through which pipe will penetrate roof 2 Determine center point of roof Pitch is...

Page 9: ...nst open edge of flashing see Figure 14 Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 14 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminatio...

Page 10: ...Rule CAUTION All gas piping and connectionsmustbe tested for leaks after the installation is completed After ensuring that the gas valve is on apply soap and water solution to all connectionsandjoint...

Page 11: ...de of the hearth Figure 20 then tilt the top of the panel toward the firebox surround Hearth Right Face Slot Figure 20 Slots for Firebrick Walls 3 Secure the firebrick wall using two of the side retai...

Page 12: ...tion When bricks are wet any excess grout mixture on bricks will easily wipe off 2 In a heavy duty mixing bucket add equal parts cement and sand Add enough water and mix together well using a power dr...

Page 13: ...od into rings at top of screen Attach one push on nut to end of rod before attaching last ring of screen 2 Insert the round end screen rod into hole on the left and right side of smoke shelf Figure 25...

Page 14: ...ing that the gas valve is on apply soap and water solution to all connectionsandjoints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER A...

Page 15: ...2 concrete drill bit not provided 5 Place rail back on bricks and align holes Secure using 9 concrete screws provided with glass door kit 6 Secure retaining clips to top and bottom rails see Figure 30...

Page 16: ...oxes can create an excessively hot fire and should not be burned in this fireplace Always keep the fire well back from the doors and never allow flames to contact the glass WARNING Fireplaces equipped...

Page 17: ...e Re place grate with INNOVATIVE HEARTH PRODUCTS model 109496 01 grate only This grate has been designed to keep the operation of your fireplace safe and efficient TECHNICAL SERVICE You may have furth...

Page 18: ...Brick Ivory 1 3 125634 01 Hearth Red 1 125634 02 Hearth Ivory 1 4 124646 01 Rear Top Red 1 124646 02 Rear Top Ivory 1 5 124648 01 Right Red 1 124648 02 Right Ivory 1 6 124650 01 Left Red 1 124650 02...

Page 19: ...2DM 24 12DM 36 12DM 48 12DM 12 12HT 18 12HT 24 12HT 36 12HT and 48 12HT 30 OFFSET AND RETURN 30E 12DM and 30E 12HT OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4F OPTIONAL OUTSIDE AIR KIT FOR SID...

Page 20: ...RIES Continued SQUARE CHASE TOP TERMINATION STL 12D ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT OPTIONAL HEARTH SPACER HS48 24 ROUND WOODNOOK DHR 24 ROOF FLASHING V6F 10DM 0 to 6 12 Pitch V12F 10DM 6...

Page 21: ...delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instruc tions...

Page 22: ...gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may...

Page 23: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 24: ...126634 01 Rev A 1 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126634 01...

Reviews: