SAFETY

 Continued

 WARNING: Do not use a blower insert, heat ex-

changer insert or other accessory not approved for 

use with this heater.

Due to high temperatures, the appliance should be 

located out of traffic and away from furniture and 

draperies.

Do not place clothing or other flammable material 

on or near the appliance. Never place any objects 

on the heater.

Fireplace become very hot when running fireplace. 

Keep children and adults away from hot surfaces to 

avoid burns or clothing ignition. Fireplace will remain 

hot for a time after shutdown. Allow surfaces to cool 

before touching.

Carefully supervise young children when they are 

in the room with fireplace. When using the remote 

control, keep selector switch in the OFF position to 

prevent children from turning on burners with remote.

Keep the appliance area clear and free from combus-

tible materials, gasoline and other flammable vapors 

and liquids.

1.  This appliance is only for use with type of gas indicated on rating 

plate. This appliance is not convertible for use with other gases.

2.  Do not place propane/LP supply tank(s) inside any structure. 

Locate propane/LP supply tank(s) outdoors (propane/LP only).

3.  If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your 

building

• leave the building immediately
• immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier’s instructions

• if you cannot reach your gas supplier, call the fire department

4.  This fireplace shall not be installed in a bedroom or bathroom.
5.  Do not use this fireplace as a wood-burning fireplace. Use only 

the logs provided with the fireplace. 

6.  Do not add extra logs or ornaments such as pine cones, vermicu-

lite, or rock wool. Using these added items can cause sooting. 

Do not add lava rock around base. Rock and debris could fall into 

the control area of fireplace.

7.  This fireplace is designed to be smokeless. If logs ever appear to 

smoke, turn off fireplace and call a qualified service person. 

  Note: During initial operation, slight smoking could occur due to 

log curing and fireplace burning manufacturing residues. 

8.  To prevent the creation of soot, follow the instructions in Cleaning 

and Maintenance, page 20.

9.  Before using furniture polish, wax, carpet cleaner, or similar 

products, turn heater off. If heated, the vapors from these prod-

ucts may create a white powder residue within burner box or on 

adjacent walls or furniture.

10. This fireplace needs fresh air ventilation to run properly. This 

fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff 

system. The ODS shuts down the fireplace if not enough fresh 

air is available. See Air for Combustion and Ventilation, page 5. 

If fireplace keeps shutting off, see Troubleshooting, page 23.

11. Do not run fireplace

• where flammable liquids or vapors are used or stored.
• under dusty conditions.

12. Do not use this fireplace to cook food or burn paper or other 

objects.

13. Do not use fireplace if any part has been under water. Immediately 

call a qualified service technician to inspect the room fireplace 

and to replace any part of the control system and any gas control 

which has been under water. 

14. Turn off and unplug fireplace and let cool before servicing. Only 

a qualified service person should service and repair fireplace.

15. Operating fireplace above elevations of 4,500 feet could cause 

pilot outage.

16. To prevent performance problems, do not use propane/LP fuel 

tank of less than 100 lbs. capacity (propane/LP only). 

17. Provide adequate clearances around air openings.
18. The screen or any other part removed for servicing must be 

replaced prior to operating this heater.

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the 

absence of local codes, use the latest edition of The National Fuel 

Gas Code ANSI Z223.1/NFPA 54*.
*Available from:

American National Standards Institute, Inc.

25 West 43rd Street, 4th floor

New York, NY 10036

National Fire Protection Association, Inc.

1 Batterymarch Park

Quincy, MA 02169-7471

Summary of Contents for Paris Lights 43ZMN

Page 1: ...r adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 5 of this manual WARNING If the information in these instructions is not followed...

Page 2: ...ore trying to assemble operate or service this heater Improper use of this heater can cause serious injury or death from burns fire explo sion electricalshockandcarbonmonoxidepoisoning DANGER Carbon m...

Page 3: ...replace is designed to be smokeless If logs ever appear to smoke turn off fireplace and call a qualified service person Note During initial operation slight smoking could occur due to log curing and f...

Page 4: ...ASSACHUSETTS REQUIRE MENTS These appliances are approved for installation in the US state of Mas sachusetts if the following additional requirements are met Un vented Room Heaters shall be installed i...

Page 5: ...gs exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b weather stripping has be...

Page 6: ...ortoadjoining room or add ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoors See Ventilation Air From Outdoors C Install a lower Btu Hr fire...

Page 7: ...moisture See Air for Combustion and Ventilation page 5 CHECK GAS TYPE Use the correct gas type natural or propane LP for your fire place If your gas supply is not correct do not install fireplace Cal...

Page 8: ...1 3 6 C 18 4 4 D 16 5 2 E 14 A B C D E 1 2 3 4 5 Wall Supplied firebox hood must be used at all times Note All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf No...

Page 9: ...75 01_D 9 17 1 2 29 7 8 29 7 8 16 3 8 7 1 8 1 7 8 8 1 4 44 1 8 1 1 55 1 8 52 47 16 1 2 11 3 4 8 1 4 5 8 INSTALLATION Continued Figure 8 ParisLights43 Series Dimensions Gas Line Access Gas Line Access...

Page 10: ...e LP supply This fireplace requires anexternalregulator notsupplied Installtheexternal regulatorbetweenthefireplaceandpropane LPsupply WARNING Never connect natural gas fireplace to private non utilit...

Page 11: ...trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sediment trap is not installed or is instal...

Page 12: ...o gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 13 2 Pressurize supply piping system by either openin...

Page 13: ...uide screw the rear panel to the fireplace as shown in Figure 16 INSTALLING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 17 2 Tighten screws securing ho...

Page 14: ...place unscrew 4 corner brackets from the firebox top See Figure 21 2 Remove 2 side walls and then the rear wall Discard rear wall 3 Replace 2 side walls and reinstall the corner brackets Installing Ac...

Page 15: ...urner shuts OFF Figure 26 Gas Module Right Side Figure 27 Gas Module Left Side Remote Control Feature The module has a built in remote control receiver that allows the user to program the remote trans...

Page 16: ...lied with the unit into the battery compart ment It is recommended that ALKALINE batteries always be used for this product Be sure the batteries are installed with the and ends facing the correct dire...

Page 17: ...default or degrees C Press the UP and DOWN Buttons simultaneously to change between degrees F and C SET TEMP While in THERMOSTAT mode press the UP or DOWN Button to change the SET TEMP 45 90 deg F 7 3...

Page 18: ...e A icon and Flame A setting number will flash in the FLAME Zone LIGHT ADJUSTMENT Transmits a light setting command to the control module to adjust the light output level Available settings are 0 off...

Page 19: ...liance requires 120V electricity for normal operation Control module should be plugged into electrical outlet located underneath firebox bottom Back up battery supply is available for power outages 1...

Page 20: ...end using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions...

Page 21: ...e running Some burner flame holes may become blocked by debris or rust with no flame present If so turn off fireplace and let cool Remove blockage Blocked burner flame holes will create soot BURNER FL...

Page 22: ...V MAX 15 AMPS 110V POWER IPI I S MAX 15 AMPS To Rocker Switch To J Box To J Box Pilot Main HI LO DC Motor Drive Light Module Black Black Brown Red Orange Orange To Ground Igniter Sensor PILOT BATTERY...

Page 23: ...t local propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance page 20 or replace ODS pilot assembly 4 Replace gas regulator 1 Contact local natural or propane LP gas company 2 Clean b...

Page 24: ...ng while cooling 1 Burner orifice is clogged or damaged 2 Damaged burner REMEDY 1 Check burner for dirt and debris If found clean burner see Cleaning and Mainte nance page 20 1 Refer to Air for Combus...

Page 25: ...y 3 Gas leak See Warning statement above 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve or gas control...

Page 26: ...Astria US com 126875 01_D 26 PARTS MODELS PARISLIGHTS43ZMN PARISLIGHTS43ZMP 11 7 4 3 8 8 8 8 14 15 16 17 18 19 20 24 21 5 22 23 6 2 1 13 10 9 12...

Page 27: ...Spark Wire 4 6 J7053 Orifice 32 1 J6989 Orifice 49 1 7 J6819 Brass Elbow 1 8 J6757 Light Bulb G9 120V 20W 4 9 J5207 Flat Washer 7 10 J4775 Bulkhead Fitting 1 11 J6834 Brass Elbow 2 12 J4714 Flextube...

Page 28: ...Astria US com 126875 01_D 28 PARTS MODELS PARISLIGHTS43ZMN PARISLIGHTS43ZMP 1 4 6 2 8 9 7 5 3 5 11 12 13 14 10 7 8...

Page 29: ...e of non approved parts can result in poor performance and safety hazards KEY NO CATALOG NO DESCRIPTION ParisLights43ZMN F1219 ParisLights43ZMP F1220 QTY 1 J6630 Top Spacer 4 2 J6566 Top Nailing Flang...

Page 30: ...ease contact your dealer IHP 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Visit us at Astria US com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed igni...

Page 31: ...riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to n...

Page 32: ...name P126875 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Co...

Reviews: