background image

Installation and Operation Instructions

Astria Marin

TM

 B-Vent Gas Fireplaces

P/N 900301-01   Rev. NC   02/2015

Ce manuel est disponible en francais, simplement  

en faire la demande. Numéro de la pièce 900301-03.

PFS

®

US

C

Models

Marin40STTMN

P900301-01

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour 

consultation ultérieure.

A barrier designed to reduce the risk of burns from 

the hot viewing glass is provided with this appliance 

and shall be installed for the protection of children 

and other at-risk individuals.

L’écran pare-étincelles fourni avec ce foyer réduit le 

risque de brûlure en cas de contact accidentel avec 

la vitre chaude et doit être installé pour la protection 

Des enfants et Des personnes à risques.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile 

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the 

rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements 

locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque 

signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.

— Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

— WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use any 

phone in your building. 

•  Leave the building immediately.

• Immediately call your gas supplier from a neigh-

bor’s phone.  Follow the gas supplier’s instructions. 

•  If you cannot reach your gas supplier, call the fire 

department.

— Installation and service must be performed by a 

qualified installer, service agency or the gas sup-

plier.

       WARNING:
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result 

in serious injury, death, or property damage.

       AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION

Le non-respect Des avertissements de sécurité 

pourrait d’entraîner des blessures graves, la mort 

ou des dommages matériels.

— Ne pas entreposer ni utilizer d’essence ni d’autres 

vapeurs ou liquides inflammables dans le voisin-

age de cet appareil ou de tout autre appareil.

— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteur. Ne pas vous 

servir des téléphones se trouvant dans le bâti-

ment où vous trouvez. 

•  Sortez immédiatement de bâtiment.

• Appelez immédiatement votre fournisseur de 

gaz depuis un voisin. Suivez les instructions du 

fournisseur. 

• Si vous ne pouvez rejoindre le fournisseur de 

gaz, appelez le service des incindies.

— L’installation et l’entretien doivent être assurés par 

un installateur ou un service d’entretien qualifié 

ou par le fournisseur de gaz.

Report No. F14-172

Summary of Contents for Marin40STTMN

Page 1: ...ut tre converti d autres gaz sauf si une trousse de conversion est utils e Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO...

Page 2: ...HER LA VITRE L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour la protection Des enfants et Des personne...

Page 3: ...gaalosni osalejadosde lachimeneaenfuncionamiento Superviseenformacercanaalos ni osencualquiercuartodondehaya unachimeneafuncionandopara impedirelcontactoconelvidrio Mantenga la ropa mobiliario gasolin...

Page 4: ...appliance For use with barrier s Part No s J7420 INTRODUCTION The Millivolt appliances have a millivolt gas control valve with piezo ignition system If any optional accessories that will require elect...

Page 5: ...h the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition InCanada thecurrentCAN CGA B149 1 installation code The appliance when installed must be electri cally grounded and wired in accordance...

Page 6: ...ERSION SHALL BE CAR RIED OUT BY A MANUFACTURER S AUTHO RIZED REPRESENTATIVE IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANU FACTURER PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN AC...

Page 7: ...ce should be located out of traffic and away from furniture and draperies Figure 3 En raison des temp ratures lev es l appareildevrait treinstall dansunendroit o il y a peu de circulation et loin du m...

Page 8: ...1 NFPA 54 CAN CGA B149 1 Multiple Terminations These appliances may vent adjacent to and at the same level with any other gas appliances includingdirect ventappliances providedthat thereisatleast2ft 0...

Page 9: ...tible materials may be installed at any height above the appliance opening however donotallowanythingtohangbelowthefireplacehood Minimumclearancerequirementsincludeanyprojectionssuchasshelves window s...

Page 10: ...to appliance location Step 3 Page 13 Install the vent system and exterior termination Step 4 Page 14 Field Wiring a Millivolt Appliances The operating control switch is factory installed Step 5 Page 1...

Page 11: ...r level a solid continuous platform must be constructed Headers may be in direct contact with the appliance top spacers but must not be supported by them or notched to fit around them All construction...

Page 12: ...WALL BRACKET Front and back edge of unit top Stepped to accept drywall on all four corners NOTE Unit has a factory installed vent seal cap and vent cover plate see Figures 22 and 23 on page 15 in eac...

Page 13: ...areful that the pipe compound does not get inside the pipe It is recommended to install a sediment trap in the supply line as close as possible to the appliance Appliances using Propane should have a...

Page 14: ...olswitchwithinthemillivoltcontrolcircuit as shown in Figure 16 using the 15 feet of 2 conductor wire supplied route wires through the snap bushing to the optional control switch Mount the optional con...

Page 15: ...er control compartment door on the side opposite the valve lifts on and off The millivolt control valve has a 3 8 10mm NPT thread inlet port Secure all joints tightly using appropriate toolsandsealing...

Page 16: ...d crawlspace not considered part of the living area of the home NOTE Do not terminate outside air kit in attic space under any circumstances CAUTION NEVER LOCATE INLET WHERE IT CANBEBLOCKEDBYSHRUBS SN...

Page 17: ...d clean out the ports With gas line installed run initial system checkout before closing up the front of the unit Follow the pilot lighting instructions providedintheCareandOperationInstructions manua...

Page 18: ...lite will NOT be used See Figure 26 DO NOT PLACE ANY VERMICULITE ON THE BURNER NOTE This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag a...

Page 19: ...he Groove At The Bottom Of Log 1 Over The Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bot...

Page 20: ...wo Charred Spots Face The Front Position The Groove In The Back Of Log 3 Against The Grate Rest Log 5 Against The Grate Here Log 5 Sits In Front Of The Grate STEP 5 NOTICE Marin model fireplaces inclu...

Page 21: ...the bottom of the door frame swing gently in towards the fireplace ensuring that the gasket seats evenly as the door frame draws shut Fasten the latch located underneath the firebox floor to the door...

Page 22: ...r Clearances Figure 32 Finishing Requirements This Area Must Remain Clear of Combustible Materials Top of Appliance 1 Min 25 mm Combustible Wall Framing Spacer Clean Face Models Top of Door Frame Hood...

Page 23: ...s safety limit switch First allow the appli ance to cool then reset the safety switch by pushing the red reset button on the back of the switch To access the blocked flue safety limit switch refer to...

Page 24: ...usement pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le bo tier de la t l commande Figure B Choisissez la langue qui est principale ment parl e dans la r sidence...

Page 25: ...door diagonally to the left away from the fireplace Remove the modesty panel by pulling the bottom right corner of the modesty panel out slightly to disengage the snap fit feature lift the modesty pa...

Page 26: ...ld side pressure test fitting and verify manifold pressure reads 3 5 water column 0 87 kPa for natural gas and 10 0 water column 2 49 kPa for propane gas Step 6 Refer to Figure 36 and remove the pilot...

Page 27: ...tact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit...

Page 28: ...ans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Si une t l commande est utilis e pour contr ler le foyer nettoyez la soigneusement pour liminer la poussi re et les trac...

Page 29: ...nvertible for use with other gases unless a certified kit is used These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degra...

Page 30: ...ess The glass should be kept clean during thefirsttwoweeksofusetopreventthefilmfrom baking on making it very difficult to remove See Cleaning Glass on Page 35 Orifice Sizes Sea Level to High Altitude...

Page 31: ...On millivolt systems the piezo igniter Hi Lo flame adjustment knob and pilot and main gas ON OFF control knob are located on the modesty panel The gas valve is located behind the modesty panel See Fig...

Page 32: ...l Knob IN OUT SIT Millivolt Gas Valve Outside Combustion Air Controls Manyappliancesareequipped wheninstalled with an outside make up air vent system that is designed to provide the appliance with out...

Page 33: ...is safety limit switch First allow the appliance to cool then reset the safety switch by pushing the red reset button on it A To access the blocked flue safety switch 1 Remove the hood by pulling stra...

Page 34: ...alified service technician inspectionshouldincludeensuringthatventing system is unobstructed and vent components are properly assembled and not damaged Homeowner must contact a qualified service techn...

Page 35: ...d Generallytheglassenclosurepanels should not be removed except to gain access to the components within the firebox Removing Glass Enclosure Panels see Figure 43 To access the glass door securing latc...

Page 36: ...be used See Figure 8 DO NOT PLACE ANY VERMICULITE ON THE BURNER NOTE This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For...

Page 37: ...rt Bracket Position The Groove At The Bottom Of Log 1 Over The Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Posit...

Page 38: ...55M20 4 Log Rear Right 55M21 5 Log Front Center 55M22 6 Log Center Top 55M23 2 6 5 4 1 3 Figure 47 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End...

Page 39: ...two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If ai...

Page 40: ...closed position until the proper flame appear ance is achieved 4 Leave the control knob off pilot on in the ON position millivolt appliances and the burner OFF ON switch OFF and remote switches if app...

Page 41: ...__________________________________________ ____________________________________________________________________ Parts will be shipped at prevailing prices at time of order When ordering repair parts a...

Page 42: ...sareavailablewithduct FOAK 4 and without duct FOAK 4LD for use if outside combustion air is required or desired If model FOAK 4LDisuseditmustbeusedinconjunction with locally purchased non combustible...

Page 43: ...The brickaded liner kits include ceramic panels as shown here The panels have brick like features in relief ACCESSORY COMPONENTS CONTINUED H0779 Top Vent Brickaded Panel Liner Kits Model Number Catal...

Page 44: ...terior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the...

Page 45: ...UCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 10 Turn gas control knob count...

Page 46: ...leuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technicien qualifi ou le fournisseur de gaz 10 Tournez le bouton de r glage du...

Page 47: ...Figures50onPage40 Cleanand oradjustpilot for maximum flame impingement on thermocouple Ensure that the connection between the valve and thermocouple are tight and secure 3 Pilot burning no gas to burn...

Page 48: ...Black 40 J7536 2 2 Glass Enclosure Assembly 40 H6365 2 3 Log Set 55M04 1 4 Bag of Vermiculite H6319 1 5 Bag of Embers Rockwool 88L53 1 6 Bag of Decorative Volcanic Stone 80L42 1 7 Burner Assembly H62...

Page 49: ...49 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 2 7 10 16 22 17 18 8 23 9 20 21 5 3 19 12 4 11 Inside Location 15 NOTE See the tables on Page 48 for replacement parts applicables REPLACEMENT PARTS 13...

Page 50: ...50 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTES...

Page 51: ...and tear accident riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product mus...

Page 52: ...5 Innovative Hearth Products Astria MarinTN B Vent Gas Fireplace P900301 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications...