Astrapool Dual Pure 100 Manual Download Page 1

 

 

ENGLISH 

 

 

Número de revisión

 Rev 001-2013-08-06 

SOMMAIRE – CONTENTS – SUMARIO – SOMMARIO 

SUMARIO – INHALTSVERZEICHNIS 

 

 

TECHNICAL SPECIFICATIONS AND GENERAL INFORMATION .................................................................. 2

 

INSTALLATION IN THE TECHNICAL AREA ................................................................................................. 3

 

INSTALLATION OF THE CHAMBER: .......................................................................................................... 4

 

PROBE: ..................................................................................................................................................... 5

 

FLOW SWITCH: ........................................................................................................................................ 5

 

INSTALLATION OF THE EARTH ELECTRODE: ............................................................................................ 6

 

ELECTRICAL CONNECTIONS: .................................................................................................................... 7

 

SERVO-CONTROLLED BY THE COVER ....................................................................................................... 8

 

OPERATING THE ELECTROLYSER .............................................................................................................. 9

 

RECOMMENDATIONS ............................................................................................................................ 10

 

SWITCHING ON THE ELECTROLYSER ...................................................................................................... 10

 

ADJUSTING CHLORINE PRODUCTION .................................................................................................... 11

 

CHLORINE ANALYSIS METHOD .............................................................................................................. 11

 

INDOOR POOL OR POOLS WITH COVERS .............................................................................................. 11

 

ADJUSTING THE DURATION OF THE POLARITY INVERSION .................................................................. 12

 

CHECKS AND MAINTENANCE ................................................................................................................ 12

 

NON-MODIFIABLE PARAMETERS: ......................................................................................................... 13

 

INDICATORS ........................................................................................................................................... 15

 

pH REGULATION .................................................................................................................................... 16

 

SWITCHING ON FOR THE FIRST TIME .................................................................................................... 17

 

TIPS FOR THE CORRECT USE OF THE pH REGULATOR ........................................................................... 18

 

TAYLOR SCALE ....................................................................................................................................... 19

 

WARRANTY ............................................................................................................................................ 19

 

 

 

 

 

 

Summary of Contents for Dual Pure 100

Page 1: ...6 ELECTRICAL CONNECTIONS 7 SERVO CONTROLLED BY THE COVER 8 OPERATING THE ELECTROLYSER 9 RECOMMENDATIONS 10 SWITCHING ON THE ELECTROLYSER 10 ADJUSTING CHLORINE PRODUCTION 11 CHLORINE ANALYSIS METHOD 11...

Page 2: ...ded stabiliser 10 15 g m3 Maximum stabiliser 40g m3 Minimum operating time per day consult the recommendations provided by the manufacturer of your filtration system Water temperature 18 C pH Use Meas...

Page 3: ...rtant ensure that the controls for the unit are accessible To prime the pH pump correctly it is important that the height between the suction line and the pH pump head do not exceed 2 metres Attach th...

Page 4: ...ws follow the direction of the arrow on the chamber the water flow must circulate between the plates electrodes Make sure that there is enough space on the removable side of the chamber to be able to...

Page 5: ...e it in the direction of the water flow Operating principle If the flow is interrupted accidentally or during a backwash and whenever the water flow rate is less than 2 9 m3 h the flow switch will cut...

Page 6: ...AL EARTH Reagent tank It is preferable to use liquid pH or pH reagents as the case may be We strongly advise against using pH correctors in powder form or hydrochloric acid Place the reagent tank near...

Page 7: ...l lose its warranty Diagram of an electrical connection example only The power of the salt electrode connect the cable supplied for this purpose The connection may be made in either direction Tighten...

Page 8: ...ero de revisi n Rev 001 2013 08 06 SERVO CONTROLLED BY THE COVER Cover panel View of the interior of the device Servo controlled connection to the cover To the cover panel connection Closed cover Clos...

Page 9: ...ENGLISH 9 N mero de revisi n Rev 001 2013 08 06 OPERATING THE ELECTROLYSER...

Page 10: ...0g m3 Minimum daily operating time respect the recommendations of the manufacturer of your filtration system Water temperature do not use below 18 C Connection 220 volts 50 60 Hz must be connected to...

Page 11: ...o different parameters UV number of bathers organic matter etc If there is an exceptionally high number of bathers then we advise you to switch the filtration to manual mode in order to compensate for...

Page 12: ...Press Menu to confirm SELF TEST Warning Water temperature 23 C minimum salt content 4g l This function allows one to check the state of the electrode and that the unit is working properly Press the TE...

Page 13: ...ppears Press twice INT appears INT intensity Press Menu the amperage is displayed Press Menu to exit the setting amperage appears Press Menu DUR appears Press 3 times TPS appears TPS tens of hours Pre...

Page 14: ...hydrogen peroxide This product cancels the chlorine reading for approximately 3 weeks The sterilizer produced by your chlorinator is compatible with most swimming pool water treatment products with th...

Page 15: ...drainage filter Stop the chlorinator during any handling of the filter s six way valve cleaning rinsing draining etc INDICATORS Flow switch fault When this indicator is lit all production is halted th...

Page 16: ...ion on the card to the connector provided for this purpose when installing a cover See page 8 19 Servo controlled Cover pH REGULATION The pH Potential Hydrogen value indicates acidity or alkalinity of...

Page 17: ...time of 2 hours per filtration cycle Other injection times are possible 1 or 4 hours per day Selecting the injection time when switching on the device the maximum dosage time is displayed 2 seconds af...

Page 18: ...ideal CAT value see the Taylor Scale below Peristaltic pump Grease the latex tube at the start of each season to maintain its elasticity To do this unscrew the 2 small screws of the transparent cover...

Page 19: ...tch the device off and then on again TAYLOR SCALE WARRANTY The unit is covered by a 2 year warranty against manufacturing defects as from the date of delivery If during this period repair of the unit...

Page 20: ...xposed to the air Whether the probe has been properly stored over the winter months replace cap over it with KCL at constant temperature or with water from the pool in a frost free area How it has bee...

Reviews: