PROHEAT II SERIES · HEAT PUMP AIR/WATER SYSTEM
© FLUIDRA 2019 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
ANEXO
Pag: 90
TABLE 2: TECHNICAL DATA [INDOORS]
PROHEAT II
35 KW 45 KW 60 KW 90 KW 120 KW
CODES
INDOOR
69649-MB 69650-MB 69651-MB 69652-MB 69653-MB
POWER SUPPLY
400 V / 50 Hz / III+N
CONDENSER
TITANIUM
COMPRESSOR
SCROLL
FANS
UNITS
Uds.
1
1
1
2
2
TYPE
RADIAL
FLOW
m
3
/h
7.850
11.500
14.500
23.000
29.000
REFRIGERANT GAS R410-A
KG
6
9
12
2X7
2X 9
WATER FLOW
m
3
/h
12-15
15-25
25-35
30-50
50-70
CONNECTION DIAMETER
mm
63
63
75
75
75
Air = 0 °C
Water = 26 °C
INLET POWER
kW
6,45
8,37
11,13
16,74
22,26
OUTLET POWER
kW
24,08
30,94
39,90
61,88
79,80
COP
3,74
3,70
3,59
3,70
3,59
Air = 5 °C
Water = 26 °C
INLET POWER
kW
6,46
8,45
11,16
16,90
22,32
OUTLET POWER
kW
27,39
35,24
45,17
70,48
90,34
COP
4,24
4,17
4,05
4,17
4,05
Air = 10 °C
Water = 26 °C
INLET POWER
kW
6,43
8,50
11,14
17,00
22,28
OUTLET POWER
kW
30,76
39,75
50,82
79,50
101,64
COP
4,78
4,68
4,56
4,68
4,56
Air = 15 °C
Water = 26 °C
INLET POWER
kW
6,62
8,55
11,04
17,09
22,08
OUTLET POWER
kW
34,93
45,03
57,47
90,06
114,94
COP
5,27
5,27
5,20
5,27
5,20
Air = 25 °C
Water = 26 °C
INLET POWER
kW
6,72
9,36
11,77
18,72
23,55
OUTLET POWER
kW
43,63
56,56
70,95
113,12
141,90
COP
6,49
6,04
6,03
6,04
6,03
Air = 30 °C
Water = 26 °C
INLET POWER
kW
7,31
9,61
12,74
19,23
25,48
OUTLET POWER
kW
48,11
61,63
78,50
123,26
157,00
COP
6,58
6,41
6,16
6,41
6,16
SOUND
PRESSURE
dbA (d*)
TBD
TBD
TBD
TBD
TBD
dbA (5 m)
TBD
TBD
TBD
TBD
TBD
d* = According to Standard UNE-EN 12102 / ISO 3744:2010
POWER AT MAXIMUM FLOW, DEPENDING ON THE MODEL
Energy Classification according to European Standard EN 14511-4 (According to FPP classification)
(Conditions: Air temp. 15 °C / Water temp. 26 °C / Relative humidity 70%)