Error messages
VLM60 User Manual
ASTECH GmbH
page 27
6
Error messages
All error messages start with the letter 'E' and a two-digit error number. The device errors are divided into
different categories, depending on the degree of severity. Critical errors require a change in programming or
operating conditions in most cases. Fatal errors indicate a serious hardware fault. The device must be checked.
Code
Meaning
Cause
E00 No error
No error occurred
-
E20 Serial console framing error
Data error during serial
transmission
USB error, wrong
communication parameter
E21 Serial console parity error
Parity error during serial
transmission
USB error, wrong
communication parameter
E22 Serial console overrun error
Internal buffer overflow
during serial transmission
Too much data traffic
E23 Serial console break error
Physical break of serial
transmission
USB error
E30 Digital potentiometer I2C error
Internal hardware error of the
LED control unit
Device defective
E31 Temperature sensor I2C error
Internal hardware error of the
temperature monitoring
Device defective
E32 EEPROM I2C error
Internal hardware error of the
parameter memory
Device defective
E40 Power LED startup failed
LED control unit could not be
initialized
Device defective or LED
defective
E41 Power LED control error
LED brightness could not be
controlled
Device defective
E42 Power LED voltage or current fault
Error in LED brightness
controlling
LED defective
E50 Motion sensor initialization error
Initialization of primary sensor
not possible
Device defective
E51 Motion sensor configuration error
Configuration of primary
sensor not possible
Device defective
E52 Motion sensor burst error
Error during data transmission
with primary sensor
Device defective
E53 Motion sensor frame capture error
Video mode of primary sensor
erroneous
Device defective or device
restart necessary