VLM60 User Manual
Fieldbus interface (Option)
page 10
ASTECH GmbH
3
Fieldbus interface (Option)
The VLM60 can be equipped with an optional fieldbus interface. The following are available
•
Ethernet (UDP, TCP),
•
Profinet IO,
•
Ethernet/IP.
The use of a fieldbus interface enables communication between evaluation units (e.g. PLC) and the measuring
device over long distances using standardized network components. In addition to the transmission of the
measured speed, the recorded lengths can also be transferred. Furthermore, it is possible to trigger
measurements in the VLM60 with the help of a control byte. Furthermore, VLM60 parameters can be set via the
bus.
The interfaces will be available for the customer shortly.