Parameter setup and measurement
LDS70A User Manual
Page 36
ASTECH GmbH
5.6
Parameter
AS
–
Auto start
The autostart function determines what the RF70A does after a cold start.
Upon connection to the supply voltage and after the internal switch-on
routine, the RF70A carries out the command automatically and sends the data
to the available outputs.
Query:
AS
Set
ASx
Value range:
BR, DM, DT, HW, ID, ID?, MF, MW, OF, PA, PR, Q1, Q2,
QA, SA, SE, SD, TE, TP
Standard
DT
BR
–
Baud rate
BR enables the adjustment of the serial baud rate. As soon as a new baud rate
has been set, the device will immediately start to communicate based on that
new baud rate. Adjust the baud rate of the connected receiver according to
the new value of BR.
Query:
BR
Set
BRx
Value range:
9600, 19200, 115200, 230400, 460800, 921600, 1843200,
2000000
Standard
115200 baud/ 8 data bits /1 stop bit / no parity
The time duration between switching on the supply voltage and the
output of the first measured value is max. 750 ms (if SA=1).