LDS70A User Manual
Operating conditions
ASTECH GmbH
Page 13
3
Operating conditions
3.1
Electrical installation conditions
For the operation of LDS70A use only a DC voltage of 10 V ... 30 V.
The limit values for the input voltage have to be observed. Do not
wire inputs as outputs.
All outputs are short circuit proof. The housing is galvanically separated from
the sensor electronics assembly. The interference resistance at electrostatic
discharge (ESD) is 4 kV according to EN 61326-1.
Table 1 : Electrical installation conditions
Electrical installation conditions of LDS70A
Supply voltage
10 V ... 30 V DC (direct current voltage)
Power consumption
< 3 W
3.2
Operating and storage conditions
Operating temperature -40
°C … +
60 °C
Storage temperature
-40 °C ... +70 °C
Air humidity
15 % ... 90 % non-condensing
The mentioned
operating and storage conditions
have to be
observed. When the operating temperatures exceed the permitted
values, the device will not be switched off automatically. The
continuous overheating of the device will reduce the lifetime of the
laser diode.
The inner temperature of the LDS70A can be distinctly higher than
the ambient temperature. If the inner temperature exceeds 85 °C
no laser light will be emitted until the temperature falls below 85°C
again.
The temperature (check with command TP) may be higher than the
ambient temperature. Approx. 30 min after power ON the
measured temperature might be 25 Kelvin higher than ambient
temperature.