Please visit www.assisianimalhealth.com for further information
.
Assisi Animal Health
Toll Free: 866-830-7342 Office: (415) 814-2460 Fax: (415) 481-0995
Operating Instructions for
Assisi Loop® 2.0 Auto-Cycle
Thank you for choosing Assisi, a non-invasive, non-drug
therapy for your pet. The Assisi Loop 2.0 Auto-Cycle is for
use only on your pet as instructed by your veterinarian.
1.
Place the center of the loop over the area that
needs treatment.
Pulsed electromagnetic
therapies may have
effects on the functioning
of powered, metallic
cardiovascular implants or
neuronal implants. Make
sure that distance is maintained from
individuals with these types of implants while Assisi
Loop is delivering treatment.
2.
Press the on/off button once. Treat for 15
minutes.
3.
After 15 minutes the device will go into “stand-
by” mode for 2 hours and will continue to cycle
through the preprogrammed mode until it is
turned off.
a.
During active treatment -- 2 therapy
indicator lights will blink every 1 second.
b.
In between treatments -- 1 therapy
indicator light will blink approximately
every 6 seconds, which indicates that the
device is in stand-by mode.
c.
To turn the device off, press the power
button. The Assisi Loop 2.0 Auto-Cycle is
off when the indicator lights do not flash.
d.
When the device is turned on again, it will
begin a new 15-minute active treatment.
4.
For optimal battery life, wait at least 2 hours
between treatments unless instructed by your
veterinarian. If your veterinarian prescribes
more frequent use, battery life could be
reduced substantially.
5.
Safety Warnings
There are no user serviceable parts inside the Assisi
Loop 2.0 Auto-Cycle.
Not protected for ingress to water. Do not get the
Assisi Loop wet.
Equipment NOT SUITABLE FOR USE IN THE
PRESENCE OF FLAMMABLE ANESTEHETIC MIXTURE
WITH AIR or WITH OXYGEN or NITROUS OXIDE or
OXYGEN ENRICHED ATMOSPHERES.
Ensure that case and applicator loop are in good
condition.
Pulsed electromagnetic therapy SHOULD NOT BE
USED on patients who have ANY implanted system
that may contain lead.
Assisi Loop 2.0 Auto-Cycle can interfere with
appliances that are designed to detect and amplify
weak radio signals. This includes televisions, radios,
citizen band radios, potentially phones and other
consumer devices in these categories. The
interference may be heard as a repetitive tick in an
FM radio and may cause tearing of a TV picture.
These consumer devices are not generally well-
shielded and are both producers of and subject to
EMI from all sources.
Applicator Etiquette
Bending or elongating the applicator too much will
hinder effectiveness. Keeping the applicator as circular
as possible provides the best field of treatment.
See protocol recommendations on
page 2 of this document.
Please visit
www.assisianimalhealth.com
for further information
.
Assisi Animal Health
Toll Free: 866-830-7342 Office: (415) 814-2460 Fax: (415) 481-0995