background image

 

Please visit www.assisianimalhealth.com for further information

 

Assisi Animal Health 

Toll Free:  866-830-7342 Office: (415) 814-2460 Fax: (415) 481-0995 

Operating Instructions for 

Assisi Loop® 2.0 Auto-Cycle 

Thank you for choosing Assisi, a non-invasive, non-drug 
therapy for your pet.  The Assisi Loop 2.0 Auto-Cycle is for 
use only on your pet as instructed by your veterinarian.

 

1.

 

Place the center of the loop over the area that 
needs treatment. 

Pulsed electromagnetic  
therapies may have  
effects on the functioning 
of powered, metallic  
cardiovascular implants or 
neuronal implants. Make  
sure that distance is maintained from 
individuals with these types of implants while Assisi 
Loop is delivering treatment.

 

 

2.

 

Press the on/off button once. Treat for 15 
minutes.  
 

3.

 

After 15 minutes the device will go into “stand-
by” mode for 2 hours and will continue to cycle 
through the preprogrammed mode until it is 
turned off. 

a.

 

During active treatment -- 2 therapy 
indicator lights will blink every 1 second. 

b.

 

In between treatments -- 1 therapy 
indicator light will blink approximately 
every 6 seconds, which indicates that the 
device is in stand-by mode. 

c.

 

To turn the device off, press the power 
button.  The Assisi Loop 2.0 Auto-Cycle is 
off when the indicator lights do not flash. 

d.

 

When the device is turned on again, it will 
begin a new 15-minute active treatment. 

 

4.

 

 For optimal battery life, wait at least 2 hours 
between treatments unless instructed by your 
veterinarian.  If your veterinarian prescribes 
more frequent use, battery life could be 
reduced substantially
.   

5.

 

Safety Warnings 

 

There are no user serviceable parts inside the Assisi 
Loop 2.0 Auto-Cycle. 

 

Not protected for ingress to water. Do not get the 
Assisi Loop wet.  

 

Equipment NOT SUITABLE FOR USE IN THE 
PRESENCE OF FLAMMABLE ANESTEHETIC MIXTURE 
WITH AIR or WITH OXYGEN or NITROUS OXIDE or 
OXYGEN ENRICHED ATMOSPHERES. 

 

Ensure that case and applicator loop are in good 
condition.  

 

Pulsed electromagnetic therapy SHOULD NOT BE 
USED on patients who have ANY implanted system 
that may contain lead. 

 

Assisi Loop 2.0 Auto-Cycle can interfere with 
appliances that are designed to detect and amplify 
weak radio signals. This includes televisions, radios, 
citizen band radios, potentially phones and other 
consumer devices in these categories. The 
interference may be heard as a repetitive tick in an 
FM radio and may cause tearing of a TV picture. 
These consumer devices are not generally well-
shielded and are both producers of and subject to 
EMI from all sources.

   

Applicator Etiquette 

Bending or elongating the applicator too much will 
hinder effectiveness.  Keeping the applicator as circular 
as possible provides the best field of treatment.  

             

 

 

See protocol recommendations on 

page 2 of this document. 

Please visit

 

www.assisianimalhealth.com 

for further information

.

 

 

Assisi Animal Health 

Toll Free:  866-830-7342 Office: (415) 814-2460 Fax: (415) 481-0995 

 

Reviews: