Please visit www.assisianimalhealth.com for further information
.
Assisi Animal Health
Toll Free: (866) 830-‐7342 Office: (415) 814-‐2460 Fax: (415) 481-‐0995
T2-MAN013
R5
Operating Instructions – Assisi Loop-‐150
Thank you for choosing Assisi, a non-‐invasive, non-‐drug
therapy for your pet. The Assisi Loop 150 offers 150 15-‐
minute treatments and is for use only on your pet as
instructed by your veterinarian.
1.
Place the center of the loop over the area that
needs treatment.
Pulsed electromagnetic
therapies may have
effects on the functioning
of powered, metallic
cardiovascular implants or
neuronal implants. Make
sure that distance is
maintained from individuals with these types of
implants while Assisi Loop is delivering treatment.
2.
Press the on/off button once. Treat for 15
minutes.
3.
After 15 minutes the device will automatically
turn itself off.
4.
If you want to treat for less than 15 minutes,
simply press the on/off button to turn the device
off.
5.
For optimal battery life, wait at least 2 hours
between treatments unless instructed by your
veterinarian. If your veterinarian prescribes
more frequent use, battery life could be reduced
substantially
.
Applicator Etiquette
Bending or elongating the applicator too much will
hinder effectiveness. Keeping the applicator as circular
as possible provides the best field of treatment.
Safety Warnings
•
There are no user serviceable parts inside the Assisi
Loop.
•
Not protected for ingress to water. Do not get the
Assisi Loop wet.
•
Equipment NOT SUITABLE FOR USE IN THE
PRESENCE OF FLAMMABLE ANESTEHETIC MIXTURE
WITH AIR or WITH OXYGEN or NITROUS OXIDE or
OXYGEN ENRICHED ATMOSPHERES.
•
Ensure that case and applicator loop are in good
condition.
•
Pulsed electromagnetic therapy SHOULD NOT BE
USED on patients who have ANY implanted system
that may contain lead.
•
Assisi Loop can interfere with appliances that are
designed to detect and amplify weak radio signals.
This includes televisions, radios, citizen band radios,
potentially phones and other consumer devices in
these categories. The interference may be heard as
a repetitive tick in an FM radio and may cause
tearing of a TV picture. These consumer devices are
not generally well-‐shielded and are both producers
of and subject to EMI from all sources.
See protocol recommendations on
page 2 of this document.
Please visit
www.assisianimalhealth.com
for further information
.
Assisi Animal Health
Toll Free: (866) 830-‐7342 Office: (415) 814-‐2460 Fax: (415) 481-‐0995
T2-MAN013 R5