16
Lock Features
Lock Soft Reset
•
In case the lock is not responsive to a
PIN code entry or Key Tag credential
and after verifying the batteries are not
flat a soft reset may be required.
•
To perform a soft reset of the lock press
the "
Reset
" button on the bottom of the
Exterior Furniture. This will restart the
lock and clear any errors.
NOTE:
Pressing the "
Reset
" button will not delete
the registered user credentials or change current
lock settings.
Key Override
•
In case the keypad is malfunctioning
or the batteries are flat, the lock is
provided with two mechanical keys.
•
To open the lock via the key, press on
the outer edge of the Exterior Lever
to expose the key cylinder. Using the
provided keys the lock can then be
unlocked.
•
Once done, reinsert the Lever Cover
to its original position.
Reset
Button
Micro USB
Advanced Function
Passage Mode turn on
(Door without locking)
5.1
(A long “beep” sounds will be heard and unlock
indicator will be light on when keypad start if the lock
is
●
5.2
Press
“ * ”
when the passage mode has been turn on.
( A long “beep” sounds will be heard and unlock
indicator
5.3
●
High Security Mode turn on
Press and release
“SET”
button three times.
(
Then press
“#”
.
(A long “beep” sound will be heard if the lock is in high
security mode.)
●
●
5.4
Press and release
“SET”
button three times.
(
Then press
“ * ”
.
(A long “beep” sound will be heard if the lock exit high
security mode.)
●
●
Built In Function
Low battery alarm
6.1
almost run out.
Need to change new batteries.
●
●
Key Operation
6.6
Press end of the lever to open cover for unlock the
door by key (even batteries run out).
●
Power shortage
6.4
In the case o nsu
ient battery, t he lock can be
powered by USB port located under the panel of lock.
Note: PIN Code & KeyCard remained unchange.
●
●
KeyCard Memory:
100 KeyCards
PIN Code:
6 ~ 10 numerical digits
Card Readable Distance:
10mm below
Battery:
4 x AAA alkaline batteries
4.8V below
Static Consumption:
40uA below
Dynamic Consumption:
300mA below
Operation Temperature:
-25C ~ +50C
Storage Temperature:
-40C ~ +55C
Relative Humidity:
10% ~ 90%
Yale EC800 Digital Leverset
USER MANUAL
(Open the Door by both PIN Code and KeyCard)
No response
6.5
●
●
●
●
●
●
●
●
●
●
Yal
e
Press here
All dimensions in millimetres
Unlock Indicator
6.2
The unlock indicator light on (green) when allow to
open door by lever.
●
KeyCard Induction Zone
6.3
●
in passage mode.)
batteries
Press PIN code or swipe KeyCard, then press
“ * ”
within
8 seconds.
Best position for detecting KeyCard.
Press “Quick Restart” button if the lock is unresponsive.
Ver1.03
5.5 Adjustable auto locking time
By default automatically lock the door after 8 seconds.
Press PIN code or swipe KeyCard, then press
“ 8888 #
5~60 # ”
within 8 seconds.
(A long “beep”sounds will be heard if adjust the closing
time succesfully.)
●
●
Low Battery
Indicator
Unlock Indicator
Key Tag Indicator
Zone
Automatically locking
5~60s adjustable range (default 8s)
●