500-23700 
Revision B 

 

 

 

WSS Wave Sense™ Switch 

Installation Instructions 

 

Package Contents 

 

 

Microwave 
motion sensor

 

 

Faceplate

 

 

Weather-resistant 
gasket 

 

Faceplate screws

 

 

Mounting ring

 

 

Instructions 

 

Adapter ring (double-gang model only)

 

 

 

 

Specifications

 

ELECTRICAL

 

INPUT   12 to 24 VAC ±10%

 

12 to 24 VDC +30%/-10%

 

 

50 to 60 Hz

 

<1.5W

 

OUTPUT

 

Relay contact rating (max voltage) 
Relay contact rating (max current) 
Max switching power

 

Relay with switch-over contact (voltage free)

 

60 VDC/125 VAC

 

1A (resistive)

 

30W (DC)/60 VA (AC)

 

DETECTION RANGE

 

4” to 24” (10cm to 60cm)(adjustable) 

DETECTION MODE

 

Motion (bidirectional)

 

OUTPUT HOLD TIME

 

0.5s (in pulsed mode)

 

OPERATING TEMPERATURE

 

-4 °F to +131 °F (-20 °C to +55 °C)

 

IMMUNITY

 

Immune to electrical and radio frequency interference

 

WEIGHT

 

0.34 lbs (0.15 kg)

 

REGULATORY

 

Electromagnetic compatibility (EMC) according to 
2004/108/EC FCC: G9B-MS08 IC: 4680A-MS08

 

Precautions 

1. 

SHUT OFF power to  power source before attempting any wiring procedures. 

2. 

MAINTAIN a clean and safe environment when working in public areas. 

3. 

Constantly BE AWARE of pedestrian traffic around the door area. 

4. 

Always

 STOP pedestrian traffic through the doorway when performing tests that may 

result in unexpected reactions by the door. 

5. 

OBSERVE

 proper protocols for circuit board handling to protect the unit from 

electrostatic discharge. 

 

Phoenix, AZ 
Tel: 1.800.624.5625 
Mon-Fri: 6:00am - 4:00pm PDT 
Fax: 1.800.232.7329 

www.securitron.com 

[email protected]

 

Summary of Contents for Securitron WSS Wave Sense

Page 1: ...d mode OPERATING TEMPERATURE 4 F to 131 F 20 C to 55 C IMMUNITY Immune to electrical and radio frequency interference WEIGHT 0 34 lbs 0 15 kg REGULATORY Electromagnetic compatibility EMC according to 2004 108 EC FCC G9B MS08 IC 4680A MS08 Precautions 1 SHUT OFF power to power source before attempting any wiring procedures 2 MAINTAIN a clean and safe environment when working in public areas 3 Const...

Page 2: ...ure to the risk of electrical shock It will void the product warranty Installation Wiring Setup Installation 1 MOUNT the WSS using the included mounting ring or in a standard plastic or metal electrical gang box as applicable and depending on the type of door installation NOTE 1 The weather resistant foam is used as a protective barrier against the elements NOTE 2 The plastic adapter ring enables ...

Page 3: ... NOTE Sensing field may be adjusted from 4 to 24 a ROTATE the potentiometer to increase the sensing field NOTE 1 Toggle Mode is recommended for switch applications In Toggle Mode a detection activates the relay and a second detection deactivates the relay NOTE 2 Pulse Mode is recommended for automatic door applications In Pulse Mode a detection activates the relay for a short period of time depend...

Page 4: ...ng output mode SWITCH the output mode to Pulse Mode 2 Wrong connection CHECK wiring and relay connection FCC Approval This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause...

Reviews: