Securitron Magnalock Corp.
www.securitron.com
ASSA ABLOY, the global leader
Tel
800.624.5625
in door opening solutions
© Copyright, 2011, all rights reserved
PN# 500-14220
Page 1
Rev. C, 06/11
EPT-SC SERIES ELECTRICAL POWER TRANSFER FOR SWING CLEAR
HINGED DOOR APPLICATIONS - INSTALLATION INSTRUCTIONS
1 DESCRIPTION
The EPT-SC allows an electric lock or exit device, such as a Securitron Touch Sense Bar or Touch
Sense Handle, to be installed while concealing and protecting the cabling between the hinged
edge of a door and its door frame. The EPT-SC provides a flexible steel shield conduit which is
approximately 5/16” [7,9mm] I.D. (inside diameter). The EL-EPT-SC is furnished with a wire
harness already installed which includes ElectroLynx® connectors at each end.
The EPT-SC power transfer device has been specifically designed and configured for installation
on doors using Swing Clear type hinges.
Note: The EPT-SC will NOT work on doors utilizing center pivot type hinges.
2 PRODUCT OVERVIEW
Upon unpacking this product, an inventory should be made to ensure
that all of the required components have been included. Along with
these instructions and the installation template, this product should
include the following items:
2.1
HARDWARE
8X 8X
4X
4X
Phillips Flat Head
#6 X 5/8” Type “A”
Phillips Flat Head
6-32 X 3/8” Type “F”
Phillips Pan Head
8-32 X 3/16”
Split Helical Washer
for #8 Screw
3 RECOMMENDED TOOLS
Router or Saber Saw
Measuring Instrument (Ruler/Tape Measure)
Hammer Masking
Tape
Chisel
Fish Tape or Lead Wire
Center Punch
Wire Strippers/Cutter
Power Drill
Crimp Wire Connectors
1/8”, 5/32” and 3/4” Drill Bits
Crimp Tool
3/8” Diameter X 82° Countersink Bit
Multimeter
Phillips and Standard Screwdrivers
4 INSTALLATION
For a proper EPT-SC install, all doors and frames must utilize a flush surface mount installation.
If the door/frame is pre-prepped by the manufacturer, then use the pre-fabricated mounting
features and the hardware provided to install the EPT-SC as discussed in Section 4.3 or 4.4. If
the installation is a field retrofit, determine the door and frame construction, then proceed to
mark the door and frame in accordance with Section 4.1.
Flexible Shield
EPT-SC Lead Cover (2)
Hardware Pack (2)
Flush Tab
Bracket (4)