background image

of 12

Performing a  

pre-installation survey 

Before installing the Magnalock, determine and 

assess the mounting location for the following:

• Physical strength of the frame 

 —  should 

be strong enough to meet or exceed the 

holding force of the Magnalock.

• Frame and vicinity

 — should offer protection 

for the wiring to prevent vandalism, and provide 

adequate protection from rain exposure.

• Door

 

inspection

 — inspect for any obstacles 

that may interfere when mounting the strike 

plate and ensure that there is minimum door 

movement when the door is latched.

• Proper

 

mounting

 —The Magnalock comes 

with factory default mounting hardware 

for use with an out-swing door.

Preparing the Magnalock 

Ensure that there is at least 2-1/4" between 

the closed door and the edge of the header.  

If not, a header bracket (sold separately) 

may be required (see 

Diagram 2)

.

Removing the cover 

and mounting bracket 

Using a Phillips screwdriver, REMOVE the two 

(2) screws that secure the cover, as shown in 

Diagram 3a

, and the (3) screws that secure 

the mounting bracket to the top of the 

lock chassis as shown in 

Diagram 3b

SET the cover and screws aside to re-attach later.

SLIDE the bracket to disengage from 

the top of the lock chassis.

Marking the frame 

PINCH and insert the template pins 

flush into the dovetail slots of the 

mounting bracket (see 

Diagram 4)

.

APPLY MASKING TAPE to the door and 

frame surfaces to protect from any possible 

damage during marking and drilling.

PLACE the mounting bracket against the frame stop 

on the secure side of the door and on the side of the 

door that does not have hinges. Ensure that there 

is a minimum a clearance of 1"  from the frame.

CLOSE the door and adjust the bracket so that 

the template pins rest against the door.

Diagram 2 Assessing the installation site

Diagram 3a Removing the cover

Diagram 4 Inserting 

the template pins

Diagram 5 Marking the frame

1-1/8" 

Bracket 

Mounting 

Surface

Anchor Screws

1-11/16" from 

door to center 

of bracket slots

1/4-20 

Blind Nut

A

A

2-1/4" from door to trailing 

edge of bracket

Diagram 3b Removing 

the mounting bracket

1" Min.

Summary of Contents for SECURITRON DEM680E Series

Page 1: ...ns Dimensions Height 2 50 64 mm Depth 2 56 65 mm Length 11 50 292 mm Certifications UL 10C Fire Rated 1 Hour CAN ULC S104 Fire Door Conformant UL 294 UL Tested Ratings Endurance 100 000 cycles ANSI BH...

Page 2: ...shown in Diagram 3a and the 3 screws that secure the mounting bracket to the top of the lock chassis as shown in Diagram 3b 2 SET the cover and screws aside to re attach later 3 SLIDE the bracket to...

Page 3: ...with template pins against the closed door using a Phillips screwdriver and two 2 1 4 20 x 1 Phillips pan head screws see Diagram 10 InstallingtheMagnalock onaWOOD DOORframe 1 DRILL two 2 3 16 diamet...

Page 4: ...tside of the door see Diagram 13 8 ATTACH the strike plate housing using six 6 6 32 x 3 8 Phillips flat head screws for METAL OR six 6 6 x 1 2 Phillips flat head screws for WOOD door 9 CRITICAL STEP P...

Page 5: ...bracket at each end and remove the Magnalock from the bracket see Diagram 17 4 ENSURE that the mounting bracket aligns with the marks and TIGHTEN the mounting screws see Diagram 18 5 USING THE BRACKET...

Page 6: ...nalock functions using Table 2 and the desired delay egress functions using Table 3 MAGNALOCK ELECTRICAL INSTALLATION Diagram 24 Location of J1 and J4 terminals Diagram 25 Terminal pin out diagram Dia...

Page 7: ...ks 30 seconds after an irrevocable alarm cycle Disabled SW 8 ON Enabled Unlocked at Startup SW 9 OFF Disabled When enabled system starts in the unlocked state Disabled SW 9 ON Enabled No Irrevocable A...

Page 8: ...agram 31 LED location Diagram 32 System settings Diagram 33 Settings labels Behavior ofDelayed EgressMagnalockswith regionalsettings California Uponpowerup lockgoes into analarmstate andrequiresamanua...

Page 9: ...V battery for installations in facilities that do not yet have commercially available power NOTE3 AccesscontrolsystemsmayregisterDPSand or BONDerrorconditionsduringthecalibrationsequence TECHTIP Fori...

Page 10: ...le and attempt to pushthedooropen Thenuisance alarmshould sound see Diagram 38 Closethedoorbefore thenuisanceinterval expires to preventthealarmstate If the nuisance alarm does not sound the strike as...

Page 11: ...ngle bond sensor failure Magnet disconnected or magnet cable wire broken Verify that the strike label has been removed Recalibrate Check for obstructions between strike and magnet Clean face of strike...

Page 12: ...E Each DEM680E comes with an NFPA exit delay door label as required by fire code 1 FOLLOW the included application instructions to apply the lettering to a door Restoring factory defaultsettings 1 DIS...

Reviews: