Keypad Programming Instructions for the Profile Series v.G1.5 Lock
To determine programming steps for your lock:
If your controller has a “G1.5” label with keypad, use the programming below; if no keypad,
refer to Section 4. If your controller has an LK label, turn to LK programming in Section 1.
For RF Technology products (G1-TU, G1-TP, G1-TA), please take note of the following advisories:
Advisory 1: There is a time delay period between initially depressing the RF FOB button and the actuation of the
lock. In some cases, the RF FOB will have to be depressed (and held for 3 seconds) multiple times to successfully
actuate the lock.
Advisory 2: In the event that there are co-located RF Technology locks using individual RF FOBs that are depressed
simultaneously, the locks may not actuate due to cross interference between the locks and the RF FOBs. The
“User” should repeatedly depress (and hold for 3 seconds) the RF FOB button until actuation of the lock occurs.
Change the Master Code
99# 1234*
Yellow LED blinks
50# 1# 1#
Yellow LED blinks
New Master Code*
Yellow LED blinks quickly
New Master Code*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
This example uses the Factory Default 1234*
Note: The Master Code must be changed (i.e., "Forced Change") prior to adding any other users.
Change the Supervisor Code
99# Master Code*
Yellow LED blinks
50# 1# 2#
Yellow LED blinks
Supervisor Code (1-6 Digits)*
Yellow LED blinks quickly
Supervisor Code (1-6 Digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Add a Supervisory Code
99# Master Code*
Yellow LED blinks
50# 10 # User Number 03-2000)#
Yellow LED blinks
User Code (1-6 digits)*
Yellow LED blinks quickly
User Code (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Enter A User Code
99# Master Code*
Yellow LED blinks
50# 1# (User Number 03-2000)#
Yellow LED blinks
User Code (1-6 digits)*
Yellow LED blinks quickly
User Code (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Enter A Panic User Code
99# Master Code*
Yellow LED blinks
50# 9# (User Number 03-2000)#
Yellow LED blinks
User Code (1-6 digits)*
Yellow LED blinks quickly
User Code (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Enter A Passage (Maintained) Code
99# Master Code*
Yellow LED blinks
50# 0# (User Number 03-2000) #
Yellow LED blinks
User Code (1-6 digits)*
Yellow LED blinks quickly
User Code (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Note: The “Passage” user has precedence over all users except the “Panic” user. The lock must toggle
back into a locked state for other users to function.
-
+
-
+
-
+
-
+
+
-
+
-
LK
-
+
-
+
-
+
-
+
+
-
+
-
LU
PK
-
+
-
+
-
+
-
+
+
-
+
-