A7857A • 800-810-WIRE (9473) • www.sargentlock.com

Door Name 5666

Seq

User

Trans

0

001

1

003

2

003

3

020

4

003

Transaction
number

Transaction
type

User

number

Door
name

Varies

Keypad Programming Instructions for the Profile Series LK Lock

Hold an infrared printer up to the infrared LED (as
shown). An HP82240B Infrared Printer can be used to
download information from the keypad to a printout.

For additional information, see “Transaction Log”.

To LED
location

Infrared
printer
(52-2069)

Note: Seq. # 0 is the
programming request 
to output the entries.
Sequence numbers 
1-9 are the actual
entries.

Enter A One Time User Code

99# Master Code* or Supervisory Code*

Yellow LED blinks

50# 5# (User Number 04-100)#

Yellow LED blinks

User Code (1-6 digits)*

Yellow LED blinks quickly

User Code (1-6 digits)*

Yellow LED blinks slowly 
(If solid, see note)

*

Yellow LED goes out

To Deactivate/Reactivate “Beep” With Key Stroke

99# Supervisory or Master Code*

Yellow LED blinks

30# 0# 0# (Off) (1# = On)

Yellow LED blinks 

*

Yellow LED blinks quickly 

*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

Note: If turning beep off, not audible on last two steps.

Reset Master Code back to factory default (1234) and retains all other User codes

99# Master Code*

Yellow LED blinks

40# 00000# 00000#

Yellow LED blinks

*

Yellow LED blinks quickly

*

Yellow LED blinks very fast for 10 sec., then slow

*

Yellow LED goes out

If the Master Code is not known, factory assistance will be required. Call 1-800-810-9473.

To Clear the Entire Memory

99# Master Code*

Yellow LED blinks

46# 00000# 00000#

Yellow LED blinks 

*

Yellow LED blinks quickly

Yellow LED goes solid and begins to blink

*

Yellow LED goes out (If solid, see note)

This deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back to 1234*, 
Sets Unlock Time to 5 seconds. If the Master Code is not known, factory assistance will be required to clear the
memory. Call 1-800-810-9473.

To Program Door Name into Keypad

99# Master Code*

Yellow LED blinks

43# Door Name (up to 5 digits)#

Yellow LED blinks 

0#

Yellow LED blinks quickly 

*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

To Interrogate Transaction Log

99# Supervisory or Master Code*

Yellow LED blinks

70# 0# 0# 

Yellow LED blinks

*

Yellow LED blinks quickly 

*

Yellow LED goes out (If solid, see note)

When done printing, the green LED will turn off and the yellow LED will blink slowly.

Yellow LED goes out

Summary of Contents for Sargent Profile G1-LU

Page 1: ...structions for the Profile Series LK and v G1 5 Locks A7857A Copyright SARGENT Manufacturing All rights reserved Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited ...

Page 2: ...e labeled G1 5 If your controller has an LK label see Section 1 for programming If your controller has a G1 5 label and a keypad see Section 3 for programming If your controller has a G1 5 label and no keypad see Section 4 for programming If your label has a G1 LU G1 PK G1 PA G1 TU G1 TP or G1 TA refer to Keypad Programming Instructions A7716 at www sargentlock com Programming differs between v G1...

Page 3: ...not have to be used or entered sequentially Note All User Codes must be followed by an asterisk The Lock Out user is location dependent all users above the chosen user number location are locked out of the keypad To ensure that all users except Master Emergency and Supervisor are locked out program this user at user number location 04 To Begin Programming The Lock Controller is preset at the facto...

Page 4: ...D blinks slowly If solid see note Yellow LED goes out Emergency Code defaults to a 10 second unlock time and will override a thrown deadbolt on a mortise lock To Enter or Change the Supervisor Code 99 Master Code Yellow LED blinks 50 1 03 Yellow LED blinks Supervisory 1 6 digits Yellow LED blinks quickly Supervisory 1 6 digits Yellow LED blinks slowly If solid see note Yellow LED goes out Enter A ...

Page 5: ...w LED blinks slowly If solid see note Yellow LED goes out Note If turning beep off not audible on last two steps Reset Master Code back to factory default 1234 and retains all other User codes 99 Master Code Yellow LED blinks 40 00000 00000 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks very fast for 10 sec then slow Yellow LED goes out If the Master Code is not known factory assist...

Page 6: ...o Set Unlock Time 99 Master Code Yellow LED blinks 11 1 99 sec 0 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly If solid see note Yellow LED goes out The Unlock Time is adjustable for Momentary Operation A 5 second unlock time is recommended to extend battery life Once the unlock time is entered it is the same for ALL users except 02 Status Indicators No Green LED after code ...

Page 7: ...sers except Master Supervisor Emergency and Panic are locked out program this user at user number location 03 The Passage user has precedence over all users except the Panic user The lock must be toggled back into a locked state for other users to function To Begin Programming The Lock Controller is preset at the factory with Master Code 1234 Entering 1234 will unlock the lock allowing the lever h...

Page 8: ...e Master Code must be changed i e Forced Change prior to adding any other users Change the Supervisor Code 99 Master Code Yellow LED blinks 50 1 2 Yellow LED blinks Supervisor Code 1 6 Digits Yellow LED blinks quickly Supervisor Code 1 6 Digits Yellow LED blinks slowly If solid see note Yellow LED goes out Add a Supervisory Code 99 Master Code Yellow LED blinks 50 10 User Number 03 2000 Yellow LED...

Page 9: ...low LED goes out Enter a Card Tag Fob and RF Fob User 99 Master Code Yellow LED blinks 50 Yellow LED blinks Select only one number below end it with a ie 4 0 Passage Code 1 Standard User 3 Lockout Code 4 Extended Unlock User 5 One Time User 7 Emergency Code 8 Communications Enable 9 Panic User Yellow LED blinks User Number 03 2000 Yellow LED blinks Yellow LED blinks Quickly Yellow LED blinks Slowl...

Page 10: ...FF Audio Beep verification on every Key Depression 99 Master Code Yellow LED blinks 30 0 0 Off 1 On Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly If solid see note Yellow LED goes out Turn ON Yellow LED verification on every Key Depression 99 Master Code Yellow LED blinks 30 1 1 On 0 Off Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly If solid see note Y...

Page 11: ...tware Hotsync door information to PDA 2 On PDA select Imp Exp Do NOT click OK at this point 3 Wake up the PA or TA lock by presenting an HID Credential or by depressing an RF Fob 4 Within a couple of seconds press and hold the PA or TA controller CommEnable push button below batteries for 2 seconds then release the button 5 On the PDA click OK 6 If there was an error check connections and repeat p...

Page 12: ... 91 7568 7568 To chain the User Number delete procedure 99 Master Code User Number a UNb UNc UN_ Using the information from the above example 99 45988 07 15 91 Type User Number User Code 1 07 77 1 15 67832 1 91 7568 When programming multiple User Numbers and Codes into the LK or G1 5 with keypad it is not necessary to leave and re enter the programming Mode 50 for each entry Multiple entries may b...

Page 13: ...g Function User Number Default Code User Programmed Code Master Code 01 1234 Supervisory Code Supplemental Individual Door Log Sheet for keypad programming Lock Model Door Name Location Table 2 User Programmed Door Log User Name User Type User Number User Code Card Fob Notes Note The factory default Master Code 1234 must be changed i e Forced Change prior to adding any other users Keypad Programmi...

Page 14: ...ations The company s customer base includes commercial construction institutional and industrial markets Copyright SARGENT Manufacturing All rights reserved Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience...

Reviews: