background image

FM9930 Floor Mounted Door Release

DR100240A

Contact Plate
Adjusting Screw
Location

THRU BOLT MOUNTING

Notes:
1. Do not scale drawing.
2. Total projection 8-3/16". (Includes Electromagnet, Armature Assembly and Floor Bracket.)
3. Power requirements: 24VAC/DC, .25 amp.
4. See Step 1 on DR100240B for switch box location. Anchor switch box to withstand a

minimum 300 lb. pull.

5. Door closing mechanism should have a 3 lb. closing force at the degree of door opening

where door armature and electromagnet engage.

6. All dimensions given in inches (mm).
7. Holding Force is 3 to 235 Pounds.

WIRING DIAGRAM

24 VAC

24 VDC

-

+

Wall Plate

Electromagnet and
Mounting Bracket
Assembly

Switch
Box

Momentary

Release Switch

(Optional)

Contact

Plate

Pull Side

of Door

Door
Plate

6-32 x 5/16" OHMS
(2 Places)

1/4-20 x 2-1/16"

THMS

(2 Places)

1-13/16

(46)

Approx. 3" (76.2)

To Door Edge

2-3/16

(55.6)

3/16

(4.8)

5-3/16

(131.8)

C

L Conduit

3/4

(19)

Door
Plate

DR100240A

www.rixson.com

ASSA ABLOY

RIXSON

®

DATE

TEMPLATE NUMBER

Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2005, 2009, Yale Security Inc., an ASSA ABLOY Group company.