FM9930 Floor Mounted Door Release
DR100240A
Contact Plate
Adjusting Screw
Location
THRU BOLT MOUNTING
Notes:
1. Do not scale drawing.
2. Total projection 8-3/16". (Includes Electromagnet, Armature Assembly and Floor Bracket.)
3. Power requirements: 24VAC/DC, .25 amp.
4. See Step 1 on DR100240B for switch box location. Anchor switch box to withstand a
minimum 300 lb. pull.
5. Door closing mechanism should have a 3 lb. closing force at the degree of door opening
where door armature and electromagnet engage.
6. All dimensions given in inches (mm).
7. Holding Force is 3 to 235 Pounds.
WIRING DIAGRAM
24 VAC
24 VDC
-
+
Wall Plate
Electromagnet and
Mounting Bracket
Assembly
Switch
Box
Momentary
Release Switch
(Optional)
Contact
Plate
Pull Side
of Door
Door
Plate
6-32 x 5/16" OHMS
(2 Places)
1/4-20 x 2-1/16"
THMS
(2 Places)
1-13/16
(46)
Approx. 3" (76.2)
To Door Edge
2-3/16
(55.6)
3/16
(4.8)
5-3/16
(131.8)
C
L Conduit
3/4
(19)
Door
Plate
DR100240A
www.rixson.com
ASSA ABLOY
RIXSON
®
DATE
TEMPLATE NUMBER
Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2005, 2009, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
03-09