Copyright © 2017 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
80-9363-0001-020 Rev 7 08/17
Page 9
Initial Setup
9
A. With building power turned off, connect 120VAC
power to power supply: HOT to “L”, NEUTRAL to
“N”, GROUND to Ground.
B. Turn on building power. Power will automatically
be On for operator. Power can be turned On or
Off by pressing the Power button shown below.
Door Moving Yellow LED
Close Position Orange LED
Power/Error Red LED
Status White LED
Learn Mode Active Blue LED
Open Position Green LED
Dry Contact Output Relay 2
Dry Contact Output Relay 1
Normally Open 24VDC Output
3 Position Switch in Endcap
These potentiometers
are Factory Preset for
standard applications.
Fine tuning may be
required for specific
applications.
Normally Closed 24VDC Output
On the control board there should be one solid
red
LED for POWER, one
white
LED that flashes every
1.5 - 2 seconds for STATUS, and one
orange
LED
flashing continuously for Close Position.
NOTE:
If
the
red
LED is flashing, check error section or
contact Technical Product Support.
C. Use the supplied green connectors to wire in any devices needing outputs, such as electric
strikes, mag locks, exit devices, door open position output, etc. See output definitions below.
Definitions:
Relay 2 Output:
Normally open relay that closes when the door is in the open position.
Relay 1 Output:
Normally open relay that closes for 3 seconds after an activation to power open.
Normally Closed 24VDC Output:
24VDC output up to 1.3 Amp draw that opens for 5 seconds
after an activation to open.
Normally Open 24VDC Output:
24VDC output up to 1.3 Amp draw that closes after an
activation to open.