Pull Side Body Assembly Installation
3
Mounting Pad
1/4-20 X
3-3/4” Length
Cap Screws
1
2
3
4
A. Install the Pull Side Body
Assembly to the Back Plate
using the four 1/4-20 x 3-3/4”
length cap screws. Screws
must be tightened in a cross
pattern as shown at right until
all four screws are tight.
NOTE:
The mounting pad must go
between the Body Assembly
and the Back Plate.
B. Plug in the four wiring
connectors into the Back Plate
Board. These are the temp,
encoder, motor and position
connectors.
C. Since mounting pad can
compress as screws are
tightened, make sure to double
check screws for tightness.
Power Supply / Board Assembly Installation
4
A. Install (2) 1/4-20 x 3/8” length cap
screws in the top two tapped holes
on the Back Plate leaving about
3/16” gap between head of screw
and back plate.
B. Use the keyholes in the Power
Supply / Board Bracket to slip over
the screw heads installed in Step
4A and allow the slot to drop the
bracket behind the screw heads.
The boards should always be facing
down and the power input for the
power supply should always be
positioned toward the conduit holes.
C. Tighten screws from Step 4A.
D. Plug the two harnesses into the
Back Plate Board connectors.
Note:
See Step 5 on page 6 for orienting
the Back Plate Ribbon Harness for
the proper handing of the door.
Conduit Holes
Power Input
Facing Toward
Conduit Holes
Board Facing Down
1/4-20 X 3/8”
Cap Screws
Keyhole
Threaded Holes
for Power Supply /
Board mounting.