Assa Abloy Norton 6300 Series Installation And Instruction Manual Download Page 5

Copyright © 2017 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9363-0001-020 Rev 7 08/17

Page 5

 

Pull Side Body Assembly Installation

3

Mounting Pad

1/4-20 X 
3-3/4” Length 
Cap Screws

1

2

3

4

A. Install the Pull Side Body 

Assembly to the Back Plate 
using the four 1/4-20 x 3-3/4” 
length cap screws. Screws 
must be tightened in a cross 
pattern as shown at right until 
all four screws are tight. 

NOTE:

 

The mounting pad must go 
between the Body Assembly 
and the Back Plate. 

B. Plug in the four wiring 

connectors into the Back Plate 
Board. These are the temp, 
encoder, motor and position 
connectors.

C. Since mounting pad can 

compress as screws are 
tightened, make sure to double 
check screws for tightness.

Power Supply / Board Assembly Installation

4

A. Install (2) 1/4-20 x 3/8” length cap 

screws in the top two tapped holes 
on the Back Plate leaving about 
3/16” gap between head of screw 
and back plate.

B. Use the keyholes in the Power 

Supply / Board Bracket to slip over 
the screw heads installed in Step 
4A and allow the slot to drop the 
bracket behind the screw heads. 
The boards should always be facing 
down and the power input for the 
power supply should always be 
positioned toward the conduit holes.

C. Tighten screws from Step 4A.
D. Plug the two harnesses into the 

Back Plate Board connectors. 

Note:

 

See Step 5 on page 6 for orienting 
the Back Plate Ribbon Harness for 
the proper handing of the door.

Conduit Holes

Power Input
Facing Toward
Conduit Holes

Board Facing Down

1/4-20 X 3/8” 
Cap Screws

Keyhole

Threaded Holes
for Power Supply / 
Board mounting.

Summary of Contents for Norton 6300 Series

Page 1: ...ools required Use screw pack and hardware provided to mount operator ETL certified conforms to ANSI UL standard 325 for automatic closing doors and UL10C Positive Pressure Fire Test for Door Assemblie...

Page 2: ...tion Opening and Closing Adjustments Setting Accessory Dip Switches Connecting Inputs Cover Installation Troubleshooting Pull Side Template Page 3 Page 4 Page 5 Page 7 Page 8 Page 9 Page 10 Page 11 Pa...

Page 3: ...aluminum No 14 x 2 3 4 70mm long sheet metal screws for wood Door Prep Page 3 Standards ETL Certified conforms to ANSI UL standard 325 for automatic closing doors and UL10C Positive Pressure Fire Test...

Page 4: ...screws If self drilling self tapping screws are used drill first mounting hole using a 3 16 drill and supplied screw Note Holes used for mounting the Back Plate are marked with a center mark on pull s...

Page 5: ...pad can compress as screws are tightened make sure to double check screws for tightness Power Supply Board Assembly Installation 4 A Install 2 1 4 20 x 3 8 length cap screws in the top two tapped hole...

Page 6: ...ng connector on the board closest to the frame attach the Back Plate Ribbon Harness to the board NOTE The connectors on the harness are keyed to allow for proper installation see illustration below Wh...

Page 7: ...ely 30 and mate the slider in the track to the tapped hole on the end of the arm Use the 3 16 hex wrench to rotate the slider bolt counter clockwise until the slide is tight in the arm Conduit Holes E...

Page 8: ...feels from the door opening and closing during manual use is controlled by this function B If required adjust the closing force nut in the end of the tube to the desired setting using a 3 4 deep well...

Page 9: ...set for standard applications Fine tuning may be required for speci c applications Normally Closed 24VDC Output On the control board there should be one solid red LED for POWER one white LED that flas...

Page 10: ...tion and hold the door there NOTE If there is a wall or door stop at the open position do not hold the door against the wall or stop Press and release the OPEN button on the board see illustration at...

Page 11: ...andard for Power Assist and Low Energy Power Operated Doors for opening and closing based on the door width and weight Opening Speed Adjustment Sweep Speed Adjustment Speed of door closing from open t...

Page 12: ...h for Special Application Requests Spare 2 Available Dip Switch for Special Application Requests Connecting Inputs 14 A Use green 2 position connectors attached to board to add any necessary inputs to...

Page 13: ...ruction Input 8 Obstruction 2 Contact closure of this input while the door is closed or opening triggers the operator to stall If the contact is not removed after 10 seconds of closure the operator wi...

Page 14: ...ocess If the door hit an obstruction reset to factory defaults by pressing and holding the POWER button until all LEDs light up then release Repeat Step18 to set Open and Closed Positions and Learn pr...

Page 15: ...late Copyright 2017 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9363...