Copyright © 2017 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
80-9363-0001-020 Rev 7 08/17
Hollow Metal Door Frame Reinforcing
Frame
Material
12 Ga.
.1046
(2.66)
14 Ga.
.0747
(1.90)
16 Ga.
.0598
(1.52)
18 Ga.
.0478
(1.21)
12 Ga.
.1046
(2.66)
10 Ga.
.1343
(3.41)
10 Ga.
.1343
(3.41)
8 Ga.
.1644
(4.18)
18 Ga.
.0478
(1.21)
12 Ga.
.1046
(2.66)
12 Ga.
.1046
(2.66)
10 Ga.
.1343
(3.41)
Reinforcing
Recommended
Min. Required
1/8"
(3)
Door
Frame
Templating is based on 1/8" gap between door and frame.
Fasteners for Frame:
• 1/4-20 Machine screws for hollow
metal and aluminum.
• No. 14 x 2-3/4 “ (70mm) long sheet
metal screws for wood.
Door Prep
Page 3
Standards
ETL Certified
; conforms to ANSI/UL standard 325 for
automatic closing doors and UL10C Positive Pressure Fire
Test for Door Assemblies .
ANSI A156.19:
These products are designed to conform to this specification
“for power assist and low energy power operated doors.”
These products are designed to exceed all the requirements
for the “Low Energy Power Operated Door.”
Americans with Disabilities Act (A.D.A.)
These door operators can be installed and adjusted to
conform with A.D.A. regulations.
ANSI A117.1:
These door controls permit door assemblies to
conform to the requirements of this specification “for
buildings and facilities - providing accessibility and
usability for physically handicap people.”
Technical Data
Notes:
Permanent wiring is to be employed as
required by local codes.
Activation devices: push plates, access
control, mats, touchless wall switches, etc.
Maximum wire size is:
12AWG at terminals LINE and NEUTRAL
(120VAC; 60Hz) on Power Input Terminal.
14AWG at all other terminals.
120VAC, 60Hz
24 V DC, max. 6.5 Amp. ; 1.3A Available Acc.
36 - 48" (91-122 cm)
90-200 lb. (41-91 kg)
Input power:
Power supply:
Door width:
Door weight:
Push min angle:
110° with reveal of 6-3/4” max
Hold open time:
5-30 seconds (A.D.A. 5 seconds min.)
Indefinite for Hold Open Input or cap switch
Push max angle:
Pull max angle:
180
°
130
° with reveal of 1/8” min