Connector Inputs (cont.)

14

Input 6:

 Hold Open

Continuous contact closure of this input triggers the operator to go to the open position and stay there 

until the contact is removed. If the door is pulled away from the open position, the operator will close 
completely and reopen to the open position and stay in the open position until the contact is removed.

Input 7:

 Obstruction 1

Contact closure of this input while the door is open or closing triggers the operator to return to the 

open position. This is used in conjunction with presence sensors mounted to the closing side of a door 
to prevent the door from hitting an obstruction.

Input 8:

 Obstruction 2

Contact closure of this input while the door is closed or opening triggers the operator to stall. If the 

contact is not removed after 10 seconds of closure, the operator will return to the closed position. This 
is used in conjunction with presence sensors mounted to the opening side of a door to prevent the 
door from hitting an obstruction.

Input 9:

 Security Override

Continuous contact closure of this input triggers the operator to disable Input 2 / Activation 2. This is 

typically used for switching off an outside wall plate.

Input 10:

 Spare input for Special Application Requests.

Input 11:

 Spare input for Special Application Requests.

Cover Installation

15

A. Align the cut outs in the cover to the pinion 

squares.

B. Use the end caps and body as a guide to slide 

the cover onto the unit.

C. Push / snap cover so it locks securely to the 

back plate.

WARNING: Make sure no wiring is loose or can 

be caught by the cover when it is snapped 
into place.

D. For pull side units, cover can be snapped onto 

track.

Right Hand Pull
Side shown

Summary of Contents for Norton 6300 Series

Page 1: ...ools required Use screw pack and hardware provided to mount operator ETL certified conforms to ANSI UL standard 325 for automatic closing doors and UL10C Positive Pressure Fire Test for Door Assemblie...

Page 2: ...tion Opening and Closing Adjustments Setting Accessory Dip Switches Connecting Inputs Cover Installation Troubleshooting Pull Side Template Page 3 Page 4 Page 5 Page 7 Page 8 Page 9 Page 10 Page 11 Pa...

Page 3: ...aluminum No 14 x 2 3 4 70mm long sheet metal screws for wood Door Prep Page 3 Standards ETL Certified conforms to ANSI UL standard 325 for automatic closing doors and UL10C Positive Pressure Fire Test...

Page 4: ...screws If self drilling self tapping screws are used drill first mounting hole using a 3 16 drill and supplied screw Note Holes used for mounting the Back Plate are marked with a center mark on pull s...

Page 5: ...pad can compress as screws are tightened make sure to double check screws for tightness Power Supply Board Assembly Installation 4 A Install 2 1 4 20 x 3 8 length cap screws in the top two tapped hole...

Page 6: ...ng connector on the board closest to the frame attach the Back Plate Ribbon Harness to the board NOTE The connectors on the harness are keyed to allow for proper installation see illustration below Wh...

Page 7: ...ely 30 and mate the slider in the track to the tapped hole on the end of the arm Use the 3 16 hex wrench to rotate the slider bolt counter clockwise until the slide is tight in the arm Conduit Holes E...

Page 8: ...feels from the door opening and closing during manual use is controlled by this function B If required adjust the closing force nut in the end of the tube to the desired setting using a 3 4 deep well...

Page 9: ...set for standard applications Fine tuning may be required for speci c applications Normally Closed 24VDC Output On the control board there should be one solid red LED for POWER one white LED that flas...

Page 10: ...tion and hold the door there NOTE If there is a wall or door stop at the open position do not hold the door against the wall or stop Press and release the OPEN button on the board see illustration at...

Page 11: ...andard for Power Assist and Low Energy Power Operated Doors for opening and closing based on the door width and weight Opening Speed Adjustment Sweep Speed Adjustment Speed of door closing from open t...

Page 12: ...h for Special Application Requests Spare 2 Available Dip Switch for Special Application Requests Connecting Inputs 14 A Use green 2 position connectors attached to board to add any necessary inputs to...

Page 13: ...ruction Input 8 Obstruction 2 Contact closure of this input while the door is closed or opening triggers the operator to stall If the contact is not removed after 10 seconds of closure the operator wi...

Page 14: ...ocess If the door hit an obstruction reset to factory defaults by pressing and holding the POWER button until all LEDs light up then release Repeat Step18 to set Open and Closed Positions and Learn pr...

Page 15: ...late Copyright 2017 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9363...

Reviews: