Copyright © 2017 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
80-9363-0001-020 Rev 7 08/17
Page 11
Opening and Closing Adjustments
12
A. Turn potentiometers (shown below) to make any adjustments. The table below shows the times
required per ANSI/BHMA A156.19 (American National Standard for Power Assist and Low Energy
Power Operated Doors) for opening and closing based on the door width and weight.
Opening Speed
Adjustment
Sweep Speed Adjustment
(Speed of door closing from
open to Latch Speed Range)
Latch Speed Adjustment
(Speed of door closing
from Sweep/Latch
transition point to close)
Hold Open Delay
(5-30 sec)
Open Delay 1
(Delay before door opens
after an activation from
Input 1)
Open Delay 2
(Delay before door opens
after an activation from
Input 2)
Contact Factory for
assistance with
additional settings
Available adjustment for
Special Application
Requests
Increase
Decrease