Fail Secure / Fail Safe Electric Strike Wiring
Operation:
Door is normally closed and latched.
Activating switch will unlock the electric strike and the door will automatically
open. Door will close after hold open time delay has elapsed.
• For Fail Secure Strike
The door will remain
locked
during power failure.
• For Fail Safe Strike
The door will
unlock
during power failure.
JMP503
NC
NO
Radio Frequency Function Option
Notes:
1. Power input to Door Operator Unit is at
“T1” Power Input Terminal (not shown)
120VAC 60Hz.
2. Radio Frequency Feature can be
purchased as a separate kit and
installed as pictured below.
Operation:
Door is normally closed.
Activating wireless switch or hand held
wireless transmitter will open the door.
Door will close after hold open delay elapses.
Optional Door 2
Door 1
1
2
3
4
5
433MHz Receiver
(Mounted on Operator)
Wiring for Momentary
Hold Open Function
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Jumper Settings
Place jumper to upper position
for normally closed (Fail Safe)
operation or to lower position
for normally open (Fail Secure)
operation.
3-5 Jumper wire
22ga or larger
copper wire only
(not provided)
RF Receiver
Unit
DC Electr
ic Str
ik
e
+
-
Wall Switch, Card Reader,
Key Switch, etc.
Normally Open Momentary
dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)