1. Align Close Position Magnet with sensor.
2. Turn power on at the Unit On/Off Switch
located on the end cap.
3. Turn Breaker Switch to "Reset" (Breaker
Switch shown in step 8). Red LED in
breaker should be on and circuit board
LEDs should illuminate.
Inverter Control Board Adjustments:
Based on function adjustment desired, use
table below to determine which POT is to
be adjusted.
Required:
Magnets must be adjusted for
specific application.
WARNING
ELECTRIC SHOCK RISK!
(Adjustments made in the shaded
area should be performed by
Authorized Factory Personnel.)
POT
FUNCTION
DESCRIPTION
OBSTR SENS
Obstruction Detection on Open
CW - Increase
CCW - Decrease
M/DLY
Motor Delay on Opening
CW - Increase
CCW - Decrease
P1
Sweep Closing Force (90° - 20°)
CW - Increase
CCW - Decrease
H/O TM
Hold Open Time (5 - 30 Seconds)
CW - Increase
CCW - Decrease
P2
Latch Force (20° - 0°)
CW - Increase
CCW - Decrease
H/O TQ
Motor Torque at Hold Open
Backcheck Position
CW - Increase
CCW - Decrease
E
Power-On Procedures
9
Control Set-Up
10
ADJUSTMENT TABLE
Signage
11
Affix "Caution" Labels on both sides
of the door. Labels should be
centered across the width of the door
and 50" from the floor.
Center
50"
Open Position
Magnet
Close Position Magnet
Sensor