Assa Abloy Norton 5630 Series Installation And Instruction Manual Download Page 7

Copyright © 2013, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

ASSA ABLOY

80-9356-0005-020 (01-14)

7

L2

115Y

L1

115/230VAC IN

MOTOR OUT

L2

230Y

U

V

W

STATUS LEDS

PUSH PULL

SW501

ON

H/O TQ

H/O TM

OBSTR

SENS

P1

M/DLY

P2

1

2

1

6

COM

SNS

COM

PB

K1

K2

11

JMP503

NC

NO

TB501

E

1. Align Close Position Magnet with sensor. 
2. Turn power on at the Unit On/Off Switch 

located on the end cap.

3. Turn Breaker Switch to "Reset" (Breaker 

Switch shown in step 8). Red LED in 
breaker should be on and circuit board 
LEDs should illuminate.

Inverter Control Board Adjustments:

Based on function adjustment desired, use 
table below to determine which POT is to 
be adjusted.

Required: 

Magnets must be adjusted for 

specific application.

WARNING

ELECTRIC SHOCK RISK!

(Adjustments made in the shaded 

area should be performed by 

Authorized Factory Personnel.)

POT

FUNCTION

DESCRIPTION

OBSTR SENS 

Obstruction Detection on Open

CW - Increase
CCW - Decrease

M/DLY

Motor Delay on Opening

CW - Increase
CCW - Decrease

P1

Sweep Closing Force (90° - 20°)

CW - Increase
CCW - Decrease

H/O TM

Hold Open Time (5 - 30 Seconds)

CW - Increase
CCW - Decrease

P2

Latch Force (20° - 0°)

CW - Increase
CCW - Decrease

H/O TQ

Motor Torque at Hold Open 
Backcheck Position

CW - Increase
CCW - Decrease

E

Power-On Procedures

9

Control Set-Up

10

ADJUSTMENT TABLE

Signage

11

Affix "Caution" Labels on both sides 
of the door. Labels should be 
centered across the width of the door 
and 50" from the floor.

Center

50"

Open Position

Magnet

Close Position Magnet

Sensor

Summary of Contents for Norton 5630 Series

Page 1: ...e Screwdriver Phillips size 2 Tape ruler Power drill Center punch Wire stripper 7 drill 1 4 20 tap metal frame install Tools required Use screw pack and hardware provided to mount operator ETL certifi...

Page 2: ...ates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority having jurisdiction These are not required by current ANSI BHMA A156 19...

Page 3: ...butt hinges Maximum frame reveal is 4 for this application Before beginning the installation verify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow met...

Page 4: ...3 16 4x 15 16 2 2 1 2 6 5 8 4 3 4 4 1 8 1 2 Operator Mounting WARNING DO NOT REMOVE ARM FROM OPERATOR WARNING ARM MUST CLEAR FRAME SOFFIT 1 Left hand door illustrated 1 Using template locate and prepa...

Page 5: ...agnets are used to signal the unit at closed and fully open positions With door in the closed position slide Close Position Magnet so it aligns directly with the sensor With door in the open position...

Page 6: ...rminal Description HOT COM Common power lead Neutral Hot power lead 120VAC 60Hz Input Wiring Instructions Grounding 7 WARNING UNIT WILL NOT FUNCTION CORRECTLY WITHOUT PROPER GROUNDING GROUND WIRE MUST...

Page 7: ...ion adjustment desired use table below to determine which POT is to be adjusted Required Magnets must be adjusted for specific application WARNING ELECTRIC SHOCK RISK Adjustments made in the shaded ar...

Page 8: ...ly closed Activating either switch will open both doors Door will close after hold open time delay has elapsed Door 1 Optional Door 2 Wave to Open Switch Wiring Operation Door is normally closed Activ...

Page 9: ...Radio Frequency Feature can be purchased as a separate kit and installed as pictured below Operation Door is normally closed Activating wireless switch or hand held wireless transmitter will open the...

Page 10: ...Lock Fail Safe Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 1 2 3 4 5 6 Signal input Signal common Relay output K2 Relay output K1 24 VDC 24 VDC 3 5 Jumper wire 22ga or...

Page 11: ...2x 1 5 16 1 1 8 6 5 8 2 1 2 2 14 16 1 2 Hinge or Pivot 2x 1 3 16 4x 15 16 2x 1 4 20 Machine Screws or Self Drilling Screws See Page 3 Figure 1 Frame Soffit Frame Rabbet Hinge or Pivot 16 1 2 2x 1 3 1...

Page 12: ...as come loose The door is binding or obstructed Control switch is set to OFF position Re install arm and key Inspect hinges and frame for wear or obstruction Change the setting of the ON OFF switch Ad...

Page 13: ...le or in part without the express written permission of Yale Security Inc is prohibited ASSA ABLOY 80 9356 0005 020 01 14 13 For assistance contact Norton Technical Product Support at 877 974 2255 300...

Reviews: