Technical Data

Notes:

   Input connections - torque to 4.8 in/lbs (.55nm)

Permanent wiring is to be employed as required by local codes.

 

  Activation devices: push plates, access control, mats, touchless wall switches, etc.

Maximum wire size is:

12AWG at terminals HOT and COM (120VAC; 60Hz) on “T1” Power Input Terminal.
14AWG at terminals 1 thru 4 on Accessory Terminal .

120VAC, 60Hz

.6 amps

24 V DC, max. 1.1 Amp.
32-36" (81-91cm)  

100-150 lb. (45-68 kg)

Input power:
Power consumption:

Power supply:

Door width*:

Door weight:
Door opening angle:

 

Push arm: up to - 110°, with reveal 1-1/4" - 5"
(32 - 127 mm)

Hold open time:

0-30 seconds (A.D.A. 5 seconds min.)

5 amps

Circuit breaker:

*Interior Doors Only

Door Prep

Notes:

• All dimensions are given in inches.
• Thickness recommended for reinforcements in hollow metal doors and frames 

is charted at the left of this page.

• Do not scale drawing.
• This template information based upon use of 5" maximum width butt hinges.  
• Maximum frame reveal is 4" for this application.
• Before beginning the installation, verify that the door frame is properly 

reinforced and is well anchored in the wall.

• Unreinforced hollow metal frames and aluminum frames should be prepared 

and fitted with 1/4-20 blind rivet nuts, furnished by others.

• Concealed electrical conduit and concealed switch or sensor wires should be 

pulled to the frame before proceeding.

Hollow Metal Door Frame Reinforcing

Frame

Material

12 Ga.

.1046

(2.66)

14 Ga.

.0747

(1.90)

16 Ga.

.0598

(1.52)

18 Ga.

.0478

(1.21)

12 Ga.

.1046

(2.66)

10 Ga.

.1343

(3.41)

10 Ga.

.1343

(3.41)

8 Ga.

.1644

(4.18)

18 Ga.

.0478

(1.21)

12 Ga.

.1046

(2.66)

12 Ga.

.1046

(2.66)

10 Ga.

.1343

(3.41)

Reinforcing

Recommended

Min. Required

1/8"

(3)

Door

Frame

Templating is based on 1/8" gap between door and frame. 

Standard

Optional

Preparation for Fasteners                                                                 Figure 1

Door or Frame

Fasteners

Drill-Sizes

Self-Drilling Screw

Wood

(see Note)

3/16” (4.30 mm) 

1/4” - 20 machine screw

Metal 

Drill: #7 (0.201” dia.)
Tap:  1/4” - 20 

Sleeve nuts and bolts

Hollow

Metal

9/32” (7 mm) through;
3/8” (9.5 mm) door face
opposite to closer

Aluminum

or Wood

3/8” (9.5 mm) through

Aluminum

or Metal

No drill required

Note:

  Wood doors/frames.  

Pilot hole must be 
drilled when using  
Self-Drilling Screws.

Always consult door/frame manufacturer
for fastener compatibility with the material
of their door/frame.

Summary of Contents for Norton 5630 Series

Page 1: ...e Screwdriver Phillips size 2 Tape ruler Power drill Center punch Wire stripper 7 drill 1 4 20 tap metal frame install Tools required Use screw pack and hardware provided to mount operator ETL certifi...

Page 2: ...ates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority having jurisdiction These are not required by current ANSI BHMA A156 19...

Page 3: ...butt hinges Maximum frame reveal is 4 for this application Before beginning the installation verify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow met...

Page 4: ...3 16 4x 15 16 2 2 1 2 6 5 8 4 3 4 4 1 8 1 2 Operator Mounting WARNING DO NOT REMOVE ARM FROM OPERATOR WARNING ARM MUST CLEAR FRAME SOFFIT 1 Left hand door illustrated 1 Using template locate and prepa...

Page 5: ...agnets are used to signal the unit at closed and fully open positions With door in the closed position slide Close Position Magnet so it aligns directly with the sensor With door in the open position...

Page 6: ...rminal Description HOT COM Common power lead Neutral Hot power lead 120VAC 60Hz Input Wiring Instructions Grounding 7 WARNING UNIT WILL NOT FUNCTION CORRECTLY WITHOUT PROPER GROUNDING GROUND WIRE MUST...

Page 7: ...ion adjustment desired use table below to determine which POT is to be adjusted Required Magnets must be adjusted for specific application WARNING ELECTRIC SHOCK RISK Adjustments made in the shaded ar...

Page 8: ...ly closed Activating either switch will open both doors Door will close after hold open time delay has elapsed Door 1 Optional Door 2 Wave to Open Switch Wiring Operation Door is normally closed Activ...

Page 9: ...Radio Frequency Feature can be purchased as a separate kit and installed as pictured below Operation Door is normally closed Activating wireless switch or hand held wireless transmitter will open the...

Page 10: ...Lock Fail Safe Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 1 2 3 4 5 6 Signal input Signal common Relay output K2 Relay output K1 24 VDC 24 VDC 3 5 Jumper wire 22ga or...

Page 11: ...2x 1 5 16 1 1 8 6 5 8 2 1 2 2 14 16 1 2 Hinge or Pivot 2x 1 3 16 4x 15 16 2x 1 4 20 Machine Screws or Self Drilling Screws See Page 3 Figure 1 Frame Soffit Frame Rabbet Hinge or Pivot 16 1 2 2x 1 3 1...

Page 12: ...as come loose The door is binding or obstructed Control switch is set to OFF position Re install arm and key Inspect hinges and frame for wear or obstruction Change the setting of the ON OFF switch Ad...

Page 13: ...le or in part without the express written permission of Yale Security Inc is prohibited ASSA ABLOY 80 9356 0005 020 01 14 13 For assistance contact Norton Technical Product Support at 877 974 2255 300...

Reviews: