WARNING: 

Make sure that (120V, 60Hz) input power is turned off at facility’s main circuit breaker before 

General Information

proceeding with installation. Do not remove arm for installation.

Operation:

 

Your Low Energy Operator can be configured in three variations to meet the standards:

 

 

1. Push plates, Wave-to-open switches, etc. are available to activate the operator. 

 

 

2. Push & Go can be enabled. In this mode, your door is pushed (or pulled) 5° manually, and then 

automatically opens to full open position. 

 

 

3. Door can be used as a manual door (Door Closer Mode). The door will work and act like a 

standard door closer, with power,  when pushed or pulled open manually. Push plates still active.

 

If desired, overhead presence devices can be provided for an extra level of protection. Consult local authority 
having jurisdiction. These are not required by current ANSI/BHMA A156.19 standards.

Opening:

 

When an opening signal is received by the control unit, the door opens to the fully open position. The open 

position is held by the motor. If the door is obstructed while opening, the door will stop; the operator will 
sense obstruction and the door will close.

 

Note: Door must be visible by person operating activation switch(es). Auxiliary door stop (by others) required.

 

Closing:

 

When the hold open time has elapsed, the operator will close the door automatically, using the motor. The 
door will slow to low speed at latch before it reaches the fully closed position. The door is kept closed by low 
power. If the door is obstructed while closing, the door will stop; the operator will sense obstruction, stop and 
stall. If obstructed more than two minutes, the unit will turn off. To reset, manually close the door, cycle power 
and turn switch on. Activate push plates to test operation.

!

Summary of Contents for Norton 5630 Series

Page 1: ...e Screwdriver Phillips size 2 Tape ruler Power drill Center punch Wire stripper 7 drill 1 4 20 tap metal frame install Tools required Use screw pack and hardware provided to mount operator ETL certifi...

Page 2: ...ates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority having jurisdiction These are not required by current ANSI BHMA A156 19...

Page 3: ...butt hinges Maximum frame reveal is 4 for this application Before beginning the installation verify that the door frame is properly reinforced and is well anchored in the wall Unreinforced hollow met...

Page 4: ...3 16 4x 15 16 2 2 1 2 6 5 8 4 3 4 4 1 8 1 2 Operator Mounting WARNING DO NOT REMOVE ARM FROM OPERATOR WARNING ARM MUST CLEAR FRAME SOFFIT 1 Left hand door illustrated 1 Using template locate and prepa...

Page 5: ...agnets are used to signal the unit at closed and fully open positions With door in the closed position slide Close Position Magnet so it aligns directly with the sensor With door in the open position...

Page 6: ...rminal Description HOT COM Common power lead Neutral Hot power lead 120VAC 60Hz Input Wiring Instructions Grounding 7 WARNING UNIT WILL NOT FUNCTION CORRECTLY WITHOUT PROPER GROUNDING GROUND WIRE MUST...

Page 7: ...ion adjustment desired use table below to determine which POT is to be adjusted Required Magnets must be adjusted for specific application WARNING ELECTRIC SHOCK RISK Adjustments made in the shaded ar...

Page 8: ...ly closed Activating either switch will open both doors Door will close after hold open time delay has elapsed Door 1 Optional Door 2 Wave to Open Switch Wiring Operation Door is normally closed Activ...

Page 9: ...Radio Frequency Feature can be purchased as a separate kit and installed as pictured below Operation Door is normally closed Activating wireless switch or hand held wireless transmitter will open the...

Page 10: ...Lock Fail Safe Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts 1 2 3 4 5 6 Signal input Signal common Relay output K2 Relay output K1 24 VDC 24 VDC 3 5 Jumper wire 22ga or...

Page 11: ...2x 1 5 16 1 1 8 6 5 8 2 1 2 2 14 16 1 2 Hinge or Pivot 2x 1 3 16 4x 15 16 2x 1 4 20 Machine Screws or Self Drilling Screws See Page 3 Figure 1 Frame Soffit Frame Rabbet Hinge or Pivot 16 1 2 2x 1 3 1...

Page 12: ...as come loose The door is binding or obstructed Control switch is set to OFF position Re install arm and key Inspect hinges and frame for wear or obstruction Change the setting of the ON OFF switch Ad...