Copyright © 2013, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9356-0005-020 (01-14)
2
WARNING:
Make sure that (120V, 60Hz) input power is turned off at facility’s main circuit breaker before
General Information
proceeding with installation. Do not remove arm for installation.
Operation:
Your Low Energy Operator can be configured in three variations to meet the standards:
1. Push plates, Wave-to-open switches, etc. are available to activate the operator.
2. Push & Go can be enabled. In this mode, your door is pushed (or pulled) 5° manually, and then
automatically opens to full open position.
3. Door can be used as a manual door (Door Closer Mode). The door will work and act like a
standard door closer, with power, when pushed or pulled open manually. Push plates still active.
If desired, overhead presence devices can be provided for an extra level of protection. Consult local authority
having jurisdiction. These are not required by current ANSI/BHMA A156.19 standards.
Opening:
When an opening signal is received by the control unit, the door opens to the fully open position. The open
position is held by the motor. If the door is obstructed while opening, the door will stop; the operator will
sense obstruction and the door will close.
Note: Door must be visible by person operating activation switch(es). Auxiliary door stop (by others) required.
Closing:
When the hold open time has elapsed, the operator will close the door automatically, using the motor. The
door will slow to low speed at latch before it reaches the fully closed position. The door is kept closed by low
power. If the door is obstructed while closing, the door will stop; the operator will sense obstruction, stop and
stall. If obstructed more than two minutes, the unit will turn off. To reset, manually close the door, cycle power
and turn switch on. Activate push plates to test operation.
!