InControl 3270 and ToConnect 3270
Incedo™ Open Quick Start Brochure 1.0
1
For more information, see:
Incedo™ Open InControl 3270 / ToConnect 3270 Installation Guide
Incedo™ Open User Guide
Controller Unit Specifications
Power supply
17-30 V DC. A UPS solution is recommended
Internal current consumption
At 27.8 V: 96 mA Max 120 mA
PoE
PoE+ 30 W IEEE 802.3af/at
Power Out
12-14 V DC, max 1.6 A (independent of
power option)
Operating environment
+5 ° C to +40 ° C, RH 5 % to 95 %
IP class
44
Dimensions (housing)
182.3 x 182.3 x 45.5 (W x H x D mm)
Maximum number of Door
controllers per Controller
16
Controller Unit Overview
Hardware components such as electric strikes and readers are
connected to Controllers and Door controllers on terminal
blocks. Settings for either controller unit can be made on the
Mode selection DIP (J), and relay jumper pins (E). The RS-485
bus is terminated on the terminal block T3 (G).
Controllers are equipped with an additional PCB (M), but the I/O
connectivity is the same for both controller units.
A)
RJ-45 Ethernet connector PoE+
B)
RJ-45 Ethernet connector (no PoE)
C)
Tamper switch
D)
Terminal block T1: Analogue inputs and relay outputs
E)
Relay jumper pins
F)
Terminal block T2: DC IN, Hi-O, DC OUT
G)
Terminal block T3: RS-485
H)
RS-485 termination
I)
Add-on card connector
J)
Mode selection DIP
K)
Label with QR code and MAC Address for Door controller
L)
Controllers only: Additional PCB with QR code and MAC
address label for Controller
The MAC address is used to map controller units in the Incedo™
Open web application. The (InControl 3270) Controller has two
separate MAC addresses, since it can act both as a Controller and
a Door Controller.
LED Indicators
Controller and Door controller LED reference:
LED Col
Name
On
Blinking
D1
Red
Input IN1
Input is active (triggered)
Sabotage (wire cut)
D2
Red
Input IN2
Input is active (triggered)
Sabotage (wire cut)
D3
Red
Input IN3
Input is active (triggered)
Sabotage (wire cut)
D4
Yellow Relay RE1
Relay is active
n/a
D5
Yellow Relay RE2
Relay is active
n/a
D6
Red
Not used
n/a
n/a
D7
Yellow DC out over-
load
12 V DC output and/or
onboard relays draw current
beyond capacity
n/a
D8
Red
Hi-O encrypted Hi-O bus is locked (en-
crypted)
n/a
D9
Green Hi-O unlocked
Hi-O bus is unlocked
n/a
D10 Green RS-485 RX
Data is being received over
the RS-485 bus
n/a
D11 Red
RS-485 TX
Data is being transmitted
over the RS-485 bus
n/a
D12 Yellow Voltage
detected
Voltage between 12-28 V de-
tected on the DC IN terminal
or the PoE+ port
n/a
D13 Red
Not used
n/a
n/a
D14 Green Network status
Door controller is communi-
cating with the Controller.
IP address received
D15 Blue
Service status
Door controller is not running
the firmware
Door controller is running
the firmware
D16 Blue
Controller
status
n/a
Slow blinking: Controller
is working, connected
to cloud. Fast blinking:
Controller is not connected
to cloud.
D17 Green Number of
connected
devices
n/a
Blinking to indicate number
of connected devices (Door
controller or WellCom
units). One blink per con-
nected device, then a pause
for 3-4 seconds (repeated).
D18 Red
Number of
disconnected
devices
n/a
Blinking to indicate number
of disconnected devices
(Door controller or Well-
Com units). One blink per
disconnected device, then
a pause for 3-4 seconds
(repeated).
RE1
RE2
RS-485
DC OUT
Hi-O
DC IN
D10
D1
D2
D3
D4
D5
D6
D7
D8
D9
D11
D13
D12
D15
D14
D16
D17
D18
Warning!
Ensure that the controller unit is powered off before
connecting or disconnecting any wire or cable.