background image

8

 9

1

2

Prox Module

#6-32 Module Mounting Screws (for optional strike mount)
Reader/Antenna Body
Reader/Antenna Mounting Screws
Reader/Antenna Cover

1

2

3

4

5

6

7

24” Antenna Cable (connecting reader/antenna and Prox Module)

8

2 pin DPS & LBM Pigtail Connector

11

Dielectric Grease (apply to connections for humid applications)

10

4 pin 12V Strike Power Pigtail
8 pin Connector Prox Module Pigtail

RF0010: Prox Module

Installation Supplement

To be used when RF0010 is added to an electric strike

HES, Inc.
Phoenix, AZ
800-626-7590

The Prox Module can be supported by the
electrical connection to the electric strike, or 
by mounting it directly to the back of some
models of HES electric strikes using the #6-32 
module mounting screws.  Do not attempt to 
support the Prox Module with the 24”
antenna cable.

Access Control System

Control Panel and Power Supply

(By others)

Wiring Diagram

Dielectric
Grease

 6

11

7

4

 5

 10

Door Position Sensor (DPS)

To Electric Strike

Power

8 Pin Connector (Prox Module) Pigtail

Red                                (+) Board Power
Black                             (   ) Board Power
Green                           Data 0
White                           Data 1
Yellow                          LED/Buzzer
Blue                               Not Used
Orange                         Not Used
Brown                           Not Used

-

 10

2 pin Connector (Strike Module)

Tan                    Common
Pink                   Door Closed and Latch Engaged

 8

4 Pin Connector (12V Strike Power)

Red       (12VDC +)       Strike Power
Black            (−)              Strike Power

 9

9

To Electric Strike 

LBM

12

12

DPS/LBM adapter

Prox Module Electrical Specifications

Operating Voltage 

12VDC +/- 20%

Operating Current 

125 mA Max @ 12VDC

Cable Detail

Distance to Host 

500 ft Max

Recommended Type 

18-24 AWG

(Dependent on distance) Stranded and shielded

Certifications

Compliance   

FCC Part 15/IC Class B

Door Position Sensor (DPS)

Contact Rating 

300ma @ 30VDC

Switch Type   

Form A (SPST) Reed

www.hesinnovations.com

Prox Module credential specifications

Card reader   

HID

® 

13.56 MHz

Supported credential formats

Recognizes HID 26 - 39 bit formats
Supports HID 125 kHz credentials

Interfaces with any Weigand-compatible access
control system