15
EN
Electrical data
Designation
Value
Operating rated voltage
230 V AC + 10 % / -15 %
Maximum output current
380 mA with 24 V DC
Protection class
IP20
Protection Class
II
Contact loaded (alarm relay)
Maximum 1 A (24 V) resistive load
Locking element
Operating rated voltage
24 V DC
Power consumption
Depending on variant
Switching duration
100 % SD
Protective circuit
Integrated freely operating diode
Recommended power supply cable
NYM-J 3 x1,5 mm² or
NYM-O 2 x 1,5 mm²
Fusing the power supply cable
10 A (automatic fuse)
Recommended connecting cables
Type
External locking elements
J-Y(ST)Y 2 x 2 x 0,8 (maximum 20 m)
Additional smoke switch
J-Y(ST)Y 2 x 2 x 0,8 (maximum 20 m)
Manual triggering button
J-Y(ST)Y 2 x 2 x 0,8 (maximum 20 m)
Alarm relay
J-Y(ST)Y 2 x 2 x 0,8
Power consumption
DC700G-
S
CO-(C)S
CO-S1
CO-FM
CO-FMS
Nominal current consumpti-
on with 24 V DC
75 mA
2 x
75 mA
75 mA
90 mA
90 mA
DC700G-
FM
FMS
FMS-K
Nominal current consumpti-
on with 24 V DC
90 mA
90 mA
90 mA
DC700G-
830-3
830-5
830-8
830-12
Nominal current consumpti-
on with 24 V DC
20 mA
25 mA
45 mA
105 mA