Cylinder Installations (cont .)
a
Interchangeable Core Installation (cont .)
• Insert key marked CONTROL and turn clockwise
approximately 15°. See Figure 7.
• Insert core into lever and return key to its
original horizontal position locking core in place.
See Figure 8.
• Withdraw key. Test lockset for correct function
with operating key.
• Control key has no further use in lockset
installation and must be safeguarded for return
to security personnel when installation is complete.
b
Interchangeable Core Removal
To remove interchangeable core:
• Insert key marked CONTROL and turn clockwise
approximately 15°. See Figure 9.
• Pull core and tailpiece completely out of lever.