The different operating modes
Locked (Off) 01
The door rotates to its home position. If an electromechanical lock is fitted, the lock is activated. The
door can be opened with the key impulse switch, see
Key impulse switch (option) on page 11
Note! If the door is placed in an escape route, selecting operating mode Locked or setting the ON/OFF
switch in the OFF (0) position, disables by default the escape function.
The door may however be configured to make escape possible, also when the door is locked. See
How to check break-out configuration
on page
.
ILL-00180
Key impulse switch
Automatic operation 02
The door is parked in standby position when there is no traffic. As soon as the outside or inside ac-
tivation units detect approaching traffic, the door starts rotating.
ILL-00189
Continuous rotation 06
The door rotates at a low speed. As soon as the outside or inside activation units detect approaching
traffic, the door accelerates to normal speed. The door returns to low speed when there is no traffic.
ILL-00190
Manual operation “Cleaning position” 07
The door rotates forward as long as the key + is held down and backwards as long as the key - is held
down.
Note! During manual operation, safety devices are disconnected.
+
-
1003090-en-12.0
Issue 2020-10-09
12