background image

Master module

SP33-M

5918230  

APR 2013

NM-0010-1

 

Model 

Profile color

Mounting height 

Detection area

Detection method

Depth angle

adjustment

Power supply * 

Power consumption

LED indicator
Test input

Presence impulse 1

Presence impulse 2

: SP33-M                 

: Black     

: 1.5 (4'11") to 3.0m (9'10") 

: See 

DETECTION AREA

: Triangulation

: 0° to +25°

: 12 to 24VAC ±10% (50 / 60 Hz)

  12 to 30VDC ±10%
: < 1.3W (< 2VA at AC) at Min. configuration

  < 3.5W (< 4.5VA at AC) at Max. configuration
: See chart below
: Opto coupler  10 to 30VDC

  Current / 6mA Max.

Output hold time

Response time

Operating temperature

Operating humidity

IP rate

Performance level

: Approx. 0.5 sec.

: <75msec.

:  -20 to +55°C (-4 to 131°F)

: <80%     

: IP54

: d (EN ISO13849-1 : 2008)

The specifications herein are subject to change without prior notice due to improvements.

NOTE

WARNING

CAUTION

NOTE

Disregard of warning may cause improper operation causing death or serious injury of 

a person. 

Special attention is required to the section of this symbol.

Setting to meet the requirements by DIN18650

Disregard of caution may cause improper operation causing injury of a person or damage to 

objects. 

NOTE

LED indicator

The following conditions are not suitable for sensor installation :  

 - Fog or exhaust emission around the door.

 - Wet floor.

 - Moving objects or objects that emit light near the detection area. 

 - Highly reflecting floor or highly reflecting objects around the door.

 

NOTE

 Solid Green

Slow Green blinking

Twice Green blinking

 Blinking Red

Status

Stand-by

Opening side detection (output 1)

Closing side detection (output 2)

Incomplete Initialization

Learning

Incomplete learning

Saturation

Sensor failure

Sensor module 

indicator

Communication error

 Solid Red

 Solid Orange

Red & Green blinking

Yellow & Red blinking

 Slow Red blinking

Fast Red blinking

Twice Orange blinking

Blinking Yellow

Profile

Front cover

Mounting clip

LED module

Spacer

Endcap

Power supply connector

Communication connector

LED indicator   

Dipswitch A

Dipswitch B

Function switch

Angle adjustment screw

(1)

(2)

(3)

(4)

(5)

(6)

(7) 

(8)

(9)

(10)

(11)

(12) 

(13)

NOTE

Make sure to fix the sensor modules firmly by the mounting clips.

: Form C relay 

  Voltage /  42VDC

  Current /  0.3A Max (Resistance load)

  Output : see 

INSTALLATION

 

                chapter 

3. Wiring

* : The sensor has to be connected to a 

     door system is equipped with a SELV circuit.

     The overcurrent protection of power supply

     cable has to be less than 2A.

(7)

(8)

(10)

(11)

(12) (8)

(7)

The lens that is marked "Tx" must be positioned onto the corresponding door edge.

Refer to 

DETECTION AREA 

for the sensor module position. The sensor module can be inserted 

in reverse as shown below. To do this,detach the mounting clip and rotate the sensor module by 180° 

and reattach the mounting clips.

unit : mm (inch)

It is required to check the operation manual if this symbol is shown on the product.

Install the sensor at 1.8m (5'11") 

to 2.5m (8'2").

WARNING

Do not wash, disassemble, rebuild or repair the sensor otherwise 

it may cause electric shock or breakdown of the equipment. 

Danger of electric shock

Read this operation manual carefully before use to ensure proper operation of this product.

Failure to read this operation manual may cause improper operation and may result in serious injury or death of a 

person.The meanings of the symbols are as follows.Please study the following first and then read the contents of this

operation manual.

1. This sensor is a non-contact switch intended for door mounting and to use on automatic swing doors. 

2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.

3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to

    the sensor.

4. Only use the sensor as specified in the operation manual provided.

5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which 

    the sensor is installed.

6. Before leaving the installation site make sure that the sensor is operating properly and instruct the building

    owner/operator on proper operation of the door and the sensor.

7. The sensor settings can only be changed by an installer or service engineer. When changed, the 

   changed settings and the date shall be registered in the maintenance logbook accompanying the door.

ENGLISH

ON

ON

Tx

Slave module

(8)

(11)

(8)

1

2

3

Min. configuration

: 1 master 1 LED module

Max. configuration : 4 sensor m2 LED modules

(1)

(2)

(3)

(3)

(4)

(6)

(6)

(5)

(9)

(9)

Sensor module

MANUFACTURER'S STATEMENT

MANUFACTURER'S STATEMENT

SPECIFICATION

OUTER DIMENSIONS AND PART NAMES

INSTALLATION

2

Inserting the sensor module

1

Mounting the profile

Noise level

: <70dBA

(13)

(13)

ON

Tx

ON

ON

Tx

ON

ON

Tx

DIN 18650-1:2010 Chapter5.7.4 DIN 18650-2:2010

EN 12978:2003 +A1:2009

EN ISO 13849-1:2008

EN ISO 13849-2:2008

COMPLIANCE

Machinery Directive 2006/42/EC

Notified Body : TÜV NORD CERT GmbH Langemarckstr. 20 45141 Essen Germany

                        EC-type examination certificate No. 44 205 10 555775

DIN

DIN

LED module indicator

ON   : Solid Red

Original instructions

Category

: 2 (EN ISO13849-1 : 2008)

 - Grating floor.

NOTE

1. Take the sensor modules out of the profile.

2. If the profile is longer than the door width, cut the profile. Make sure not to scratch the front cover.

3. Affix the profile on the intended mounting position leaving more than 20mm (13/16") from door edge to 

    attach the endcap.

4. If necessary, drill two mounting holes of ø3.4mm (ø1/8”) and fix the profile. 

5. When mounting a sensor on each side of the door, it is necessary to drill a wiring hole of ø12mm (ø1/2”) to 

    connect the sensor modules. (See chapter 

3. Wiring

)

Make sure there is some space between the mounting clips and the mounting screws.

Min. 20mm

(13/16")

1

2

Make sure not to scratch the profile when making a hole.

EN 16005:2012

Presence impulse 1

OFF : Solid Green

ON   : Solid Orange

Presence impulse 2

OFF : Solid Green

The color depends on 

the state of the output.

EMC Directive 2004/108/EC

EN 61696-3:2001 clause 4. 3. 5 and 5. 4. 7. 3

50.7 (2")

44.3 (1 3/4")

X =Minimum 340mm (13 3/8")

Black screw

(small)

Silver screw

Recommended installation position

Mounting height
Detection area width 

Door width

W

h

d1

=
=
=

=
=
=

Distance from the leading edge to the sensor module

unit : mm (inch)

h

d1

d3

W

900 (2'12")

1900

(6'3")

2000

(6'7")

2100

(6'11")

2200

(7'3")

2300

(7'7")

2400

(7'11")

2500

(8'2")

760

(2'6")

790

(2'7")

825

(2'9")

870

(2'10")

895

(2'11")

920

(3')

950

(3'1")

175

(6 7/8")

160

(6 3/8")

145

(5 6/8")

125

(5")

115

(4 1/2")

110

(4 1/2")

110

(4 3/8")

d2

n
2
2
2
2
2
2
2

d3

1100 (3'7")

375

(14 3/4")

355

(14")

345

(13 5/8")

320

(12 5/8")

315

(12 3/8")

310

(12 2/8)

300

(11 6/8")

n
2
2
2
2
2
2
2

d3

1200 (3'11")

420

(16 4/8")

415

(16 2/8")

410

(16 1/8")

400

(15 3/4")

n
2
2
2
2
2
2
2

Number of sensor modules

Distance between sensor modules

d3

d2

n

70

(2 3/4")

70

(2 3/4")

70

(2 3/4")

70

(2 3/4")

70

(2 3/4")

70

(2 3/4")

70

(2 3/4")

475

(18 5/8")

460

(18 1/8")

445

(17 1/2")

Test conditions required by DIN 18650        Detection object : DIN 18650 Test body CA 

The actual detection area may become smaller depending on the ambient light, the color / material of 

the object or the floor as well as the entry speed of the object.

NOTE

NOTE

DETECTION AREA

Detection area at 2200mm (7' 2 5/8") : Depth 140 (5 1/2") x Width 870 (2'10")

Emitting area at 2200mm (7' 2 5/8")  : Depth 140 (5 1/2") X Width 440 (1' 5 1/2")

Leading edge

h

DIN 18650 

Test body CA 

d2

d3

d1

W

For instaltion heigths <1900mm the installation of an extra module will be mandatory in order to comply