background image

 

  

 

5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 

 

 

Certification Exhibit 

 
 
 
 

FCC ID:  U4A-AHGUHF00 

IC: 6982A-AHGUHF00

 

 

FCC Rule Part: 15.247 

IC Radio Standards Specification: RSS-210 

 

ACS Report Number:  10-0344.W06.11.A 

  

Manufacturer: Assa Abloy 

Model: AH13

 

 
 
 
 

Manual

 

 

Summary of Contents for Aperio

Page 1: ... USA Voice 770 831 8048 Fax 770 831 8598 Certification Exhibit FCC ID U4A AHGUHF00 IC 6982A AHGUHF00 FCC Rule Part 15 247 IC Radio Standards Specification RSS 210 ACS Report Number 10 0344 W06 11 A Manufacturer Assa Abloy Model AH13 Manual ...

Page 2: ...tion Integration Instructions WFMN5A 11MAR 2011 Copyright 2011 ASSA ABLOY All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY is prohibited EMEA Form AAWL 260 01 31 11 ...

Page 3: ...e the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is Connected Consult the dealer or an experienced radio TV technician for help Industry Canada This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subj...

Page 4: ...Technical Specifications Radio standard IEEE 802 15 4 Wireless Frequency Range y y 2400 2483 5MHz 16 channels 11 26 y y 11 25 US only Receiver Sensitivity 100dBm 20 PER Wireless Transmit Power 10dBm MHz Wireless Operating Range in office environment Indoors up to 50 feet 15m Internal Antenna Two cross polarized dipoles IP Classification IP20 Electronic Requirements Input Voltage 8 24 VDC Current 2...

Page 5: ...re Figure 2 Placement of Communication Hub Typically the LED on the Communication Hub cover should point to the lock The Communication Hub should be placed on the non secure key or card side of the door Shorter distance and light materials in the walls permits placement on opposite sides Be aware of that metallic sheet or mesh will attenuate the radio signal Inner ceiling is for example sometimes ...

Page 6: ...dition of parity bits ENABLED OFF Addition of parity is DISABLED transmitted as received When enabled addition of one even parity bit before and one odd parity bit after is applied to the actual credential Typically parity bits are already included in the creditial In this case when DIP 3 is disabled OFF transmitted credential may include parity DIP 4 Controls byte orders of transmitted credential...

Page 7: ... as is 5 Used in Pairing Mode ON Starts in pairing mode OFF Normal use 6 9 A4 Not used 10 INT EXT Internal External Antenna Use ON Internal Hub Connector Designation Description Connection DATA 1 Wiegand Data 1 signal Output from Communication Hub Used to transmit credentials Connect to Wiegand Data 1 on EAC system DATA 0 Wiegand Data 0 signal Output from Communication Hub Used to transmit credent...

Page 8: ...an the plastic adapter plate as shown in the adapter plate installation instructions it is necessary to align the tamper switch with a special tamper tower post See instructions provided with the optional mounting box Tamper Switch AH20 Relay Terminal Block DIP Switch Ground Lug Tamper Switch Main Terminal Block DPS RX Battery Tamper Figure 3 AH20 Connectors Connections for AH20 J103 AH13 AH30 Int...

Page 9: ... 8 Controls use of termination resistor between RS485 A and RS485 B ON 100 Ohm connected enabled OFF 100 Ohm disconnected disabled DIP 9 Not used DIP 10 Controls use of external antenna if required ON Selects use of internal antenna OFF Selects use of external antenna AH13 AH30 DIP Switch Configuration AH13 AH30 DIP Switch Configuration Table DIP Switch Number Label Description 1 4 A0 A1 A2 A3 Con...

Page 10: ...C Address The EAC address of the Communication Hub can be set in two ways By configuration from the Aperio Programming Application By use of the DIP switch See Dip1 Dip4 on Page 9 Selecting the RS 485 address from DIP switch through the Aperio Programming Application tool the APA tool maybe used to remotely set or override the physical dip switch address setting When the Communication Hub is set w...

Page 11: ...in must have switch 8 of the DIP switch set to the OFF position Refer to the EAC documentation for proper termination of the bus on the EAC side Pull up and pull down resistors should be enabled once bus Refer to EAC documentation for use of pull up or pull down on the EAC side If pull up and pull down from the EAC system is not used one Communication Hub on the bus should have DIP switches 6 and ...

Page 12: ...rt two screws in the through holes of the Communication Hub Communication Hub Adapter Plate Installation Physical Hub Installation Square Box Assembly Octagon Box Assembly Switch Box Assembly Handy Box Assembly plaster ring mounting plate plugs screws Communication Hub screws box Figure 6 Communication Hub Assembly Note Complete all Wiegand and DIP switch configuration prior to installing the Comm...

Page 13: ...e Aperio Lock and EAC Offline UHF Communication Green Green One Red Flash Green Two Red Flashes Green Three Red Flashes Yellow Off Fast Flash Pairing Active Yellow Figure 7 Communication Hub Normal LED Indications Figure 8 Communication Hub Normal LED Indications The Communication Hub has a single LED that supports an optical scheme with red green and yellow The indication scheme is described by t...

Page 14: ...Notes ...

Page 15: ...ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience WFMN5A 01 11 ...

Reviews: