background image

DE Seite 

2

EN Page  20

FR Page  40

IT Pagina 60

The global leader in
door opening solutions

DXXXXXNN

Installations- und Montageanleitung

Produktname
Produktname

www.assaabloy.de

NL Pagina  60

ASSA ABLOY, the global leader
in door opening solutions

Installations- und Montageanleitung
Installation and mounting instructions

D0122301

Riegel
Bolt

Türriegel Modell 843ZY
Door Bolt Model 843ZY

DE Seite 

2

EN Page  22

Summary of Contents for 4042203148697

Page 1: ...tallations und Montageanleitung Produktname Produktname www assaabloy de NL Pagina 60 ASSA ABLOY the global leader in door opening solutions Installations und Montageanleitung Installation and mountin...

Page 2: ...Verwertung bzw Ver nderung au erhalb der engen Grenzen des Urheberrechtsgesetzes ist ohne Zustimmung von ASSA ABLOY Sicherheitstechnik GmbH unzul ssig und strafbar Das gilt insbesondere f r Vervielf...

Page 3: ...erwachungsensoren 7 Montage 8 Montage mit Aufbaugeh use 8 B ndige Montage in Schlosstasche 10 Funktionspr fung 11 Elektrischer Anschluss 12 DIP Schalter 12 Anschl sse 13 Spannungsversorgung 14 Technis...

Page 4: ...ent werden Der T rriegel ist mit magnetischen und elektronischen berwachungssensoren ausgestattet zum Anschluss einer Alarmanlage zur Kontrolle f r eine Ablaufsteu erung des T rverschlusses oder zum A...

Page 5: ...hnen auch Hinweise ber die Funktion wichtiger Bauteile Bedeutung der Symbole Gefahr Sicherheitshinweis Nichtbeachtung f hrt zu Tod oder schweren Verletzungen Warnung Sicherheitshinweis Nichtbeachtung...

Page 6: ...e m ssen von Handwerksfachkr ften des passenden Gewerks oder eingewiesene Personen ausgef hrt werden Der T rriegel kann in einer passend gefr sten oder ges gten Schlosstasche montiert werden Mit dem v...

Page 7: ...nd verriegelt Wird die T r geschlossen liegt innerhalb von 15 Sekunden mehrmals die maximale Leistung an Danach wechselt der T rriegel in einen Haltemodus mit reduziertem Stromverbrauch um Erw rmung z...

Page 8: ...8 DE Montage Montage mit Aufbaugeh use T rriegel an der Zarge Schraubmontage 1 2 2 1 Montage...

Page 9: ...9 DE Montage Schlie blech auf dem Glast rblatt Klebemontage 2 1 1 2 2 1...

Page 10: ...10 DE B ndige Montage in Schlosstasche 1 2 1 2...

Page 11: ...11 DE Elektrischer Anschluss Funktionspr fung Nach Montage in Aufbaugeh use Nach Montage in Schlosstasche...

Page 12: ...Schalter S1 und S2 wird die Entriegelungsdauer eingestellt Tab 1 Sekunden DIP S1 DIP S2 0 ON ON 3 OFF ON 6 ON OFF 9 OFF OFF Werkseinstellung DIP Schalter M Der DIP Schalter M wird werkseitig eingestel...

Page 13: ...kann der Ruhestrombetrieb nicht verwendet werden Abb 3 Anschl sse 12 24 V DC 1 2 3 4 5 6 7 8 9 10 11 Nr Funktion 1 V Spannungsversorgung 2 V Steuereingang werkseitig eingestellt optional 3 V Spannungs...

Page 14: ...ng angeschlossen Abb 4 Anschluss mit Nutzung des Steuereingang 12 24 V DC 1 2 3 4 5 6 7 8 9 10 11 Spannungs versorgung bei Ruhestrombetrieb bei Arbeitsstrombetrieb 12 24 V DC 1 2 3 4 5 6 7 8 9 10 11 S...

Page 15: ...15 DE Elektrischer Anschluss Steuereingang nicht angeschlossen Abb 5 Anschluss ohne Nutzung des Steuereingangs 12 24 V DC Spannungs versorgung 1 2 3 4 5 6 7 8 bei Ruhestrombetrieb...

Page 16: ...n 1 000 000 Funktionsluft 6mm Haltekraft 10 000N Eigenschaft Auspr gung Spannungsversorgung 12VDC bis 24VDC 15 maximale Stromaufnahme bei 12 VDC 24 VDC Haltestrom Betriebsstrom 160mA 1 250mA 95mA 1 00...

Page 17: ...ontage im kommerziellen Bereich einen vern nftigen Schutz gegen sch dliche Interferenzen sicherstellen Dieses Produkt erzeugt und verwendet hochfrequente Energie im Radiofrequenzband und kann diese En...

Page 18: ...18 DE Technische Daten Abb 6 T rriegel und Schlie blech T rriegel 195 12 5 12 5 22 38 3 228 25 60 24 2 Schlie bleche 25 3 255 12 5 12 5 217 15 5 25 3 115 12 5 12 5 89 5 15 5 Ma e...

Page 19: ...al Zubeh r 255 255 19 5 29 2x M5 x 0 8 294 19 5 46 8 24 2 60 Aufbaugeh use f r Tierriegel T rschild zum Aufkleben auf R ckseite einer Glast r Aufbaugeh use f r Schlie gegenst ck 255 255 19 5 29 294 19...

Page 20: ...r eine regelm ige Funktionskontrolle einzuhalten Details dazu m ssen mit der zertifizierende Beh rde abgestimmt werden Gew hrleistung Es gelten die gesetzlichen Gew hrleistungsfristen und die Verkauf...

Page 21: ...21 DE...

Page 22: ...outside the strict limits of the copyright are prohibited and liable to prosecution unless prior consent has been obtained from ASSA ABLOY Sicherheitstechnik GmbH This particularly applies to any cop...

Page 23: ...nitoring sensors 27 Mounting 28 Mounting with surface mounted casing 28 Flush mounting in the lock pocket 30 Function check 31 Electrical connection 32 DIP switch 32 Connections 33 Power supply 34 Tec...

Page 24: ...king cylinder The door bolt is equipped with magnetic and electronic monitoring sensors for connecting an alarm system as monitoring for a sequence control system of the door lock or for connecting an...

Page 25: ...ides information on how key components work Meaning of the symbols Danger Safety notice Failure to observe these warnings will lead to death or severe injury Warning Safety notice Failure to observe t...

Page 26: ...The electrical installation and mounting must be carried out by specialist tradesmen from the relevant trade or trained persons The door bolt can be mounted in a suitably milled or sawn lock pocket Th...

Page 27: ...rical voltage in locked state If the door is closed the maximum power is applied several times within 15 seconds The door bolt then switches to a holding mode with reduced current consumption to reduc...

Page 28: ...28 EN Mounting Mounting with surface mounted casing Door bolt on the door frame screw mounting 1 2 2 1 Mounting...

Page 29: ...29 EN Mounting Striking plate on the glass door leaf adhesive mounting 2 1 1 2 2 1...

Page 30: ...30 EN Flush mounting in the lock pocket 1 2 1 2...

Page 31: ...31 EN Electrical connection Function check After mounting in surface mounted casing After mounting in lock pocket...

Page 32: ...ock period is set via the DIP switches S1 and S2 Tab 1 Seconds DIP S1 DIP S2 0 ON ON 3 OFF ON 6 ON OFF 9 OFF OFF Factory setting DIP switch M The DIP switch M is set at the factory Operating mode DIP...

Page 33: ...l input Fig 3 fail unlocked operation can not be used Fig 3 Connections 12 24 V DC 1 2 3 4 5 6 7 8 9 10 11 No Function 1 V Power supply 2 V Control input set at factory Optional 3 V Power supply 4 N O...

Page 34: ...trol input connected Fig 4 Connection using the control input 12 24 V DC 1 2 3 4 5 6 7 8 9 10 11 Power supply during fail unlocked operation during fail locked operation 12 24 V DC 1 2 3 4 5 6 7 8 9 1...

Page 35: ...35 EN Electrical connection Control input not connected Fig 5 Connection without using the control input 12 24 V DC Power supply 1 2 3 4 5 6 7 8 during fail unlocked operation...

Page 36: ...es 1 000 000 Rebate gap 6mm Holding force 10 000N Feature Characteristic Power supply 12VDC to 24VDC 15 Maximum current consumption at 12 VDC 24 VDC Holding current Operating current 160mA 1 250mA 95m...

Page 37: ...arantee effective protection from harmful interferences when mounted in commercial operation This product generates and uses high frequency energy in the radio frequency band and can emit this energy...

Page 38: ...38 EN Technical data Fig 6 Door bolt and striking plate Door dead bolts 195 12 5 12 5 22 38 3 228 25 60 24 2 Striking plates 25 3 255 12 5 12 5 217 15 5 25 3 115 12 5 12 5 89 5 15 5 Dimensions...

Page 39: ...255 19 5 29 2x M5 x 0 8 294 19 5 46 8 24 2 60 Surface mounted casing for door bolt Door escutcheon for sticking on the rear side of a glass door Surface mounted casing for locking counterpart 255 255...

Page 40: ...pecified by the door manufacturer for regular function checks must be observed Details must be agreed with the certifying authority Warranty The statutory warranty periods and Terms and Conditions of...

Page 41: ...41 EN Accessories maintenance warranty disposal...

Page 42: ...42 EN Accessories maintenance warranty disposal...

Page 43: ...43 EN Accessories maintenance warranty disposal...

Page 44: ...d to satisfying end user needs for security safety and convenience ASSA ABLOY Sicherheitstechnik GmbH Bildstockstra e 20 72458 Albstadt DEUTSCHLAND albstadt assaabloy com Tel 49 7431 123 0 Fax 49 7431...

Reviews: