Flush-Mounted Escape Door Terminal 1380
Page 38
D00428
02
5
Specifications
5.1
Key switch 1380E01/E04
Tampering contact
24 V DC/0.5 A max.
ohmic resistance
Switch unit(key switch)
24 V DC/0.5 A max.
ohmic resistance
5.2
Key switch 1380E03/06
Rated operating voltage
12 V to 24 V DC
- 15%, +15%
Rated current consumption
at 24 V DC:
Illumination:
LED indicators: 10 mA each
Buzzer: 20 mA
Tampering contact
24 V DC/0.5 A max.
ohmic resistance
Switch unit(key switch)
24 V DC/0.5 A max.
ohmic resistance
5.3
Emergency button 1380E10
Rated operating voltage
12 V to 24 V DC
- 15%, +15%
Rated current consumption
at 24 V DC:
Illumination in switch unit: 13 mA
Red LED indicator: 15 mA
Green LED indicator: 30 mA
Yellow LED indicator: 15 mA
Buzzer: 30 mA
Tampering contact
24 V DC/0.1 A max.
ohmic resistance
Switch unit
2 openers, spring-loaded
acc. to EN 60947-1, EN 60947-5-1
EN 60947-5-5, EN 418,
DIN EN 60204-1
24 V DC/2 A max.
ohmic resistance