3. PRODUCT SAFEGUARDS

SAFEGUARD

DESCRIPTION

               WARNING! 

 

Maximize Electrical 
Safety 

1.  Patients should not operate the product at any time. Always ensure that the 

Pump is unplugged when not in use.

2.  Do not disassemble the pump at any time.
3.  Do not place or store the pump close to water or any other liquid.
4.  Do not submerge the pump in water or any other liquid.
5.  Do not make contact with the pump if it has come into contact with water or 

any other liquid. BEFORE touching the pump or any associated components 
ensure that mains power has been cut off.

               WARNING! 

 

Safe use for carers 
and patients

1.  The mattress replacement must be operated by connecting it to the pump 

ensuring that it is not turned off or unplugged whilst in use.

2.  Always ensure that warning labels are adhered to ensuring that voltage is 

correct, approved power cords are used and that Children & Animals do not 
come into contact with the packaging materials that could cause suffocation.

3.  Equipment is not suitable to be used in the presence of a flammable 

anaesthetic mixture with air, oxygen or nitrous oxide.

4.  Keep away from sharp objects. 
5.  Close supervision is necessary when this Product is used by, on, or near 

children or people with disabilities.

6.  Use this Product only for its intended use as described in the user manual. 

Only use this product with Aidacare approved accessories and attachments.

7.  Do not operate this product if the pump has a damaged power cord or plug, 

plug is not working properly, has been dropped or damaged or dropped/
submerged into water or another liquid. If this occurs, contact your Aspire 
dealer immediately for a product inspection.

8.  Keep the power cord away from hot surfaces.
9.  Do not block the air valves/tubes/openings by placing on a soft surface such 

as a bed or couch.  Keep all valves/tubes/openings responsible for air flow, 
clear of all lint, hair and other particles.

10.  Do not insert any object into the air valves/tubes/openings.
11.  Avoid dropping pump and do NOT mount any heavy objects on top of it.
12.  Place the power cord and air hoses at the patient’s foot area to avoid 

strangling of the patient’s neck.

13.  Avoid electromagnetic interference by ensuring that electro-magnetic or RF 

generated equipment is kept away from the patient. 

14.  Over the course of operation, the pump will generate a small amount of heat. 

Do not maintain skin contact with pump for more than 1 minute at a time. 
Never cover the pump when it is in use, ensure air flow to pump is free at all 
times.

15.  During a power outage or loss (even if only temporary) the pump will stop 

and power failure alarm will sound for up to 20 seconds. The pump will return 
to normal operation once the power supply is resumed.

16.  Connect this product to a properly grounded outlet only. 
17.  Avoid the risk of electrocution by grounding the ground pin with grounding 

power outlet.

18.  The EMC specification is compliant with all regulations and requirements. For 

power leads with a ground pin, the connection with properly grounded power 
outlets will supress the EMC effect. The pump will work correctly for power 
leads that are not grounded.

19.  Connecting auto-detection should only be performed by the operator and not 

the patient.

Summary of Contents for ACTIVE AIR ACUTE 8 Series

Page 1: ...USER MANUAL ACTIVE AIR ACUTE 8 ALTERNATING MATTRESS REPLACEMENT PTM639400 Single PTM639410 King Single...

Page 2: ...Safety Precautions 3 Product Safeguards 4 Product Overview 5 Assembly Setup 6 Operation 7 Product Specifications 8 Cleaning 9 Maintenance Storage 10 Troubleshooting 11 Warranty Service 12 Service Log...

Page 3: ...3 Thank you for choosing this Aspire Lifecomfort Active Air Acute 8 Alternating Mattress Replacement It is important that you read this user manual carefully before using your new mattress replacement...

Page 4: ...y and or produce ineffective patient support outcomes 1 INTRODUCTION SYMBOLS USED IN THIS MANUAL The symbols below are used throughout this user manual and on the product to identify warnings and impo...

Page 5: ...utomatically increases by 15mmHg to prevent bottoming out AutoDetect Based on the patients weight and size appropriate pressure output is automatically set ensuring optimal care and protection 24 Hour...

Page 6: ...ly Residual current devices RCD are not supplied with the Product Please consult with your Biomedical Engineer advisor concerning RCD requirements The clinically quali ed person responsible should con...

Page 7: ...damaged or dropped submerged into water or another liquid If this occurs contact your Aspire dealer immediately for a product inspection 8 Keep the power cord away from hot surfaces 9 Do not block th...

Page 8: ...ent has been designed for the Hospital and Acute Care environment 4 PRODUCT OVERVIEW Simple O ring cell connector s Multi stretch vapour permeable top cover Durable base cover Side safety handles Rapi...

Page 9: ...he Pump 2 Secure the mattress replacement onto the mattress platform by fastening and securing the nylon straps and plastic buckles 5 ASSEMBLY SETUP 2 1 Box Contains 1 Digital Mattress Pump 2 Mains Po...

Page 10: ...LOSE position 4 Position the pump on the FOOT END of the bed end The spring hanger bracket assembly will self adjust onto the footboard to secure it in place 5 Remove the plastic protector cap from th...

Page 11: ...side of the pump unit until a notable click sound is heard 7 Insert 3 5mm sensor cable plug into the pump interface panel jack 8 Connect the mains power cable to the pump ensuring that the power switc...

Page 12: ...l power socket 11 Set mode suitable for patient Refer to OPERATION for further details on how to adjust the Mattress Replacement WARNING DO NOT place the Pump in an area where the power cord can becom...

Page 13: ...s modes can be set on the digital pump to ensure maximum comfort and pressure redistribution for the patient Adjustment Control Panel Operation 1 2 3 4 5 6 7 8 9 Power On Ready For Use The power switc...

Page 14: ...is reached the pump will automatically switch into the previous selected mode and comfort level after 20 minutes 1 Function Lock Out Carers can lock out functions to ensure these are not accidentally...

Page 15: ...he LED screen Pressure Mode Adjustment Static Alternating Constant Low Pressure Static Mode This function stops the mattress from alternating and maintains the set pressure level for a duration of 20...

Page 16: ...an immersion low pressure surface operating between 15mmHg to 29mmHg depending on comfort settings chosen 1 Press the MODE button until the CLP LED light is illuminated CPL PRESSURE CHART SWL 250KG CO...

Page 17: ...ested pressure according to the patients weight This is intended as a guide only as patient body shapes vary 1 1 ifecomfort ifecomfort VE 5 FIRM AUTO ADJUST CYCLE TIME MINUTES LOW PRESSURE POWER FAILU...

Page 18: ...revert to the previous mode setting Auto Adjust Correct pressure levels are automatically set dependent on patient weight when activating the Auto Adjust feature Patients with unusual body shapes may...

Page 19: ...W PRESSURE LED light will illuminate and an alarm will sound 1 If the pump senses low pressure the LOW PRESSURE LED light will illuminate and alarm 2 Refer to the Troubleshooting sticker on the base o...

Page 20: ...ion CPR 1 Locate the CPR valve at the HEAD end of the bed 2 Open the CPR valve by pulling and twisting the cylinder to the RIGHT to the OPEN position 3 Locate pump hose and disconnect from the pump 1...

Page 21: ...25 C 70 93 RH no condensation Environment Pressure 70 kPa 101 3kPa Environment Horizontal Pressure 3000m Water and Dust Protection Classification IP21 Mattress Replacement SINGLE Dimensions mm 2000mm...

Page 22: ...or single use disinfectant wipe To remove large spills or stains the top cover should be completely removed and laundered as per below procedure 1 Remove top cover by unzipping all 4 x sides from the...

Page 23: ...ealer ensuring it has the correct rating and specification Air Filter Replacement Remove the cover on the rear casing of the pump Remove old filter and reinsert a new filter fix in place with the cove...

Page 24: ...the mattress are secured If problem persists contact your Aspire dealer Pump is on but mattress will not alternate Ensure the mattress is inflated Check if ALTERNATING mode is ON Check if SERVICE REQU...

Page 25: ...ights For further information contact Aidacare on 1300 133 120 or email product aidacare com au Aidacare will not warrant the safety and or correct functioning of products where any original component...

Page 26: ...Condition Report Action taken Inspected By YEAR 3 Service Type Condition Report Action taken Inspected By YEAR 4 Service Type Condition Report Action taken Inspected By YEAR 5 Service Type Condition R...

Page 27: ...eport Action taken Inspected By YEAR 8 Service Type Condition Report Action taken Inspected By YEAR 9 Service Type Condition Report Action taken Inspected By YEAR 10 Service Type Condition Report Acti...

Page 28: ...Imported by AIDACARE P L Building 3A 1 Moorebank Avenue Moorebank NSW 2170 T 1300 133 120 W www aidacare com au ASUM40 11 160519...

Reviews: