Aspire ACTIVE AIR ACUTE 8 Series User Manual Download Page 5

5

Product Description

The Product is an Alternating Mattress Replacement System used in the prevention and relief for patients 
with, or vulnerable to, pressure injuries. This Product offers patients a comfortable and relaxing support 
surface by using the established principles of alternating therapy, which can both prevent skin breakdown 
and enhance healing. 
 
The mattress pump features a digital pressure adjustment function, mode selections and audiovisual 
alarms. 
 
The mattress features a multi-stretch PU coated fabric cover (with high MVTR) along with 20 x alternating 
air cells, 4 x static head cells and a rapid release twist CPR valve for use in the event of a CPR emergency. 

Key Features

•  Patient weight range of this mattress replacement is 30-250kg, this should not be exceeded at any time
•  1 in 3 alternating air cycle provides acute level therapy for maximum pressure redistribution and 

wound management whilst maximizing the comfort to cell pull-off ratio

• 

AutoLock

 – The control panel automatically locks if not touched for 30 seconds preventing accidental 

changes to modes and settings

•  

AutoProtect

 - When the head of the bed is raised to 25

º

 or more, air pressure automatically increases 

by +10mmHg. When the head of the bed is raised to 45

º

 or more, air pressure automatically increases 

by +15mmHg to prevent bottoming out.

•  

AutoDetect

 - Based on the patients weight and size, appropriate pressure output is automatically set, 

ensuring optimal care and protection

•  

24 Hour Transport

 - In the event of a power failure, patients can remain on the inflated surface for  

up-to 24 hours

•  

Easy-to-read LCD

 - Clear LCD screen provides concise information on cycle time selections, as well as 

operating mode and fault conditions

  Multi-stretch, Vapour Permeable Cover 

– Easy to clean cover is multi-stretch and breathable, reducing 

friction and shear whilst optimising skin microclimate

•  

Welded Seams & Zip Protection

 – Prevents fluid and bacterial ingress into the system, facilitating 

stringent infection control measures

•  

Rapid Release CPR

 – Allows quick deflation for cardio-pulmonary resuscitation in emergency situations

•  

Audible & Visual Alarms 

– Activate immediately if a problem occurs, maximising peace of mind and 

reducing patient risk

 Variable Speed Pump

 – The pump automatically runs at the minimum speed required for effective 

pressure care to reduce vibration and noise which improve patient sleep quality.

•  

Variable Cycle Times

 – A choice of 10, 15, 20, 25 or 30 minute cycles to meet the needs and comfort 

requirements for a wide range of patients

•  Simple Cell Connections

 – O-ring connections make maintenance hassle and tool free

•  Hassle Free Pump Maintenance

 – Modular Pump design ensures Pumps can be serviced and returned 

to use quickly minimizing downtime

Summary of Contents for ACTIVE AIR ACUTE 8 Series

Page 1: ...USER MANUAL ACTIVE AIR ACUTE 8 ALTERNATING MATTRESS REPLACEMENT PTM639400 Single PTM639410 King Single...

Page 2: ...Safety Precautions 3 Product Safeguards 4 Product Overview 5 Assembly Setup 6 Operation 7 Product Specifications 8 Cleaning 9 Maintenance Storage 10 Troubleshooting 11 Warranty Service 12 Service Log...

Page 3: ...3 Thank you for choosing this Aspire Lifecomfort Active Air Acute 8 Alternating Mattress Replacement It is important that you read this user manual carefully before using your new mattress replacement...

Page 4: ...y and or produce ineffective patient support outcomes 1 INTRODUCTION SYMBOLS USED IN THIS MANUAL The symbols below are used throughout this user manual and on the product to identify warnings and impo...

Page 5: ...utomatically increases by 15mmHg to prevent bottoming out AutoDetect Based on the patients weight and size appropriate pressure output is automatically set ensuring optimal care and protection 24 Hour...

Page 6: ...ly Residual current devices RCD are not supplied with the Product Please consult with your Biomedical Engineer advisor concerning RCD requirements The clinically quali ed person responsible should con...

Page 7: ...damaged or dropped submerged into water or another liquid If this occurs contact your Aspire dealer immediately for a product inspection 8 Keep the power cord away from hot surfaces 9 Do not block th...

Page 8: ...ent has been designed for the Hospital and Acute Care environment 4 PRODUCT OVERVIEW Simple O ring cell connector s Multi stretch vapour permeable top cover Durable base cover Side safety handles Rapi...

Page 9: ...he Pump 2 Secure the mattress replacement onto the mattress platform by fastening and securing the nylon straps and plastic buckles 5 ASSEMBLY SETUP 2 1 Box Contains 1 Digital Mattress Pump 2 Mains Po...

Page 10: ...LOSE position 4 Position the pump on the FOOT END of the bed end The spring hanger bracket assembly will self adjust onto the footboard to secure it in place 5 Remove the plastic protector cap from th...

Page 11: ...side of the pump unit until a notable click sound is heard 7 Insert 3 5mm sensor cable plug into the pump interface panel jack 8 Connect the mains power cable to the pump ensuring that the power switc...

Page 12: ...l power socket 11 Set mode suitable for patient Refer to OPERATION for further details on how to adjust the Mattress Replacement WARNING DO NOT place the Pump in an area where the power cord can becom...

Page 13: ...s modes can be set on the digital pump to ensure maximum comfort and pressure redistribution for the patient Adjustment Control Panel Operation 1 2 3 4 5 6 7 8 9 Power On Ready For Use The power switc...

Page 14: ...is reached the pump will automatically switch into the previous selected mode and comfort level after 20 minutes 1 Function Lock Out Carers can lock out functions to ensure these are not accidentally...

Page 15: ...he LED screen Pressure Mode Adjustment Static Alternating Constant Low Pressure Static Mode This function stops the mattress from alternating and maintains the set pressure level for a duration of 20...

Page 16: ...an immersion low pressure surface operating between 15mmHg to 29mmHg depending on comfort settings chosen 1 Press the MODE button until the CLP LED light is illuminated CPL PRESSURE CHART SWL 250KG CO...

Page 17: ...ested pressure according to the patients weight This is intended as a guide only as patient body shapes vary 1 1 ifecomfort ifecomfort VE 5 FIRM AUTO ADJUST CYCLE TIME MINUTES LOW PRESSURE POWER FAILU...

Page 18: ...revert to the previous mode setting Auto Adjust Correct pressure levels are automatically set dependent on patient weight when activating the Auto Adjust feature Patients with unusual body shapes may...

Page 19: ...W PRESSURE LED light will illuminate and an alarm will sound 1 If the pump senses low pressure the LOW PRESSURE LED light will illuminate and alarm 2 Refer to the Troubleshooting sticker on the base o...

Page 20: ...ion CPR 1 Locate the CPR valve at the HEAD end of the bed 2 Open the CPR valve by pulling and twisting the cylinder to the RIGHT to the OPEN position 3 Locate pump hose and disconnect from the pump 1...

Page 21: ...25 C 70 93 RH no condensation Environment Pressure 70 kPa 101 3kPa Environment Horizontal Pressure 3000m Water and Dust Protection Classification IP21 Mattress Replacement SINGLE Dimensions mm 2000mm...

Page 22: ...or single use disinfectant wipe To remove large spills or stains the top cover should be completely removed and laundered as per below procedure 1 Remove top cover by unzipping all 4 x sides from the...

Page 23: ...ealer ensuring it has the correct rating and specification Air Filter Replacement Remove the cover on the rear casing of the pump Remove old filter and reinsert a new filter fix in place with the cove...

Page 24: ...the mattress are secured If problem persists contact your Aspire dealer Pump is on but mattress will not alternate Ensure the mattress is inflated Check if ALTERNATING mode is ON Check if SERVICE REQU...

Page 25: ...ights For further information contact Aidacare on 1300 133 120 or email product aidacare com au Aidacare will not warrant the safety and or correct functioning of products where any original component...

Page 26: ...Condition Report Action taken Inspected By YEAR 3 Service Type Condition Report Action taken Inspected By YEAR 4 Service Type Condition Report Action taken Inspected By YEAR 5 Service Type Condition R...

Page 27: ...eport Action taken Inspected By YEAR 8 Service Type Condition Report Action taken Inspected By YEAR 9 Service Type Condition Report Action taken Inspected By YEAR 10 Service Type Condition Report Acti...

Page 28: ...Imported by AIDACARE P L Building 3A 1 Moorebank Avenue Moorebank NSW 2170 T 1300 133 120 W www aidacare com au ASUM40 11 160519...