background image

 

7 of 21 

 

Other Connections 

 

You can also use the PlugLink HD AV Pass-Thriugh Adapter with other Ethernet 
enabled devices, such as IP Cameras, IP set top box, game consoles, etc.

 

Up to 

eight (8) PL9667 can be placed on the same PLC (Powerline Communication) 
network.

 

 

Finding a Suitable Location 

 

Find a suitable location to install your PlugLink HD AV Pass-Thriugh Adapter. Where 
you install the units can affect their performance. Find a location that is: 

 

l

 

Acceptable temperature and humidity ranges. 

l

 

Free of strong electromagnetic field generators (such as motors), vibration, dust, 
and direct exposure to sunlight. 

l

 

An electrical outlet for your PlugLink HD AV Pass-Thriugh Adapter. Outlet must be 

within six feet (1.82 meters) of the device you are connecting to. 

 

 

Installing the Hardware 

 

Connect each of your PlugLink HD AV Pass-Thriugh Adapter. 

 

1.

 

Connect the unit into a nearby wall outlet (Do not plug the adapter into a power 
strip). 

 

2.

 

Connect the enclosed Ethernet cable to the Ethernet port of the unit. 

 

 

3.

 

Connect the other end of the cable to the Ethernet port of the PC or device. 

 

Congratulations! 

You  have  completed  the  installation  of  the  P L 9 6 6 7  

for normal use. 

 

 

Summary of Contents for PL9667-Q1

Page 1: ...PlugLink HD AV Pass Through Adapter User s Guide PL9667 Q1 QUICKFIND LOCATOR Contact Information Getting Help Table of Contents Installation 66 0384 01Rev 001 ...

Page 2: ...scribed in this user s guide may not be currently available Refer to the most recent product announcement for information about feature and product availability This user s guide contains the most current information available at the time of publication When new and or revised information becomes available this entire user s guide is updated and distributed to all registered users All company and ...

Page 3: ...thttp www asokatech com Getting Help Asoka USA backs its products with unparalleled customer service and technical support for our valued customers Customer Service Customer service the customer satisfaction arm of Asoka USA is available Monday through Friday from 9 00 am to 5 00 pm Pacific Time by calling 408 550 8167 or emailing custserv asokatech com Technical Support Technical support is avail...

Page 4: ... Contents 5 Types of Connections 5 Simple Connection Peer to Peer 6 Simple Broadband Connection 6 Other Connections 7 Finding a Suitable Location 7 Installing the Hardware 7 2 Troubleshooting 8 A Specifications 10 B Components 12 C Warranty 17 D FCC Notice 19 ...

Page 5: ... PlugLink HD AV Pass Thriugh Adapter PL9667 Q1 l 6 foot Ethernet cable l Quick Installation Guide l Installation Resource CD for advanced users only l Warranty and Support Information Card If any of the parts are incorrect missing or damaged contact the retailer where you made your purchase Keep the carton including the original packing materials in case you need to return the unit for repair Type...

Page 6: ...a power strip extension cord un interruptible power supply UPS or surge protector This may prevent the unit from working properly or degrade the network performance Simple Broadband Connection The following items are needed to share a Broadband connection with computers l One 1 PL9667 Q1 device attached to a standard cable DSL or wireless router l One 1 PL9667 Q1 device attached to each computer ...

Page 7: ...dity ranges l Free of strong electromagnetic field generators such as motors vibration dust and direct exposure to sunlight l An electrical outlet for your PlugLink HD AV Pass Thriugh Adapter Outlet must be within six feet 1 82 meters of the device you are connecting to Installing the Hardware Connect each of your PlugLink HD AV Pass Thriugh Adapter 1 Connect the unit into a nearby wall outlet Do ...

Page 8: ... in another electrical device such as a lamp or radio 4 Plug the PL9667 Q1 into the working electrical outlet 5 Check to see if the lights work 6 If the above does not work the device might be defective 7 Please contact Technical Support for instructions on returning the device for repair or replacement Symptom Some of my devices cannot connect to the Internet or other computers in my network The ...

Page 9: ... Q1 from the current electrical outlet 2 Locate another outlet in the home 3 Plug the PL9667 Q1 into that outlet 4 Attach a computer to the PL9667 Q1 5 Open the Power Manager Utility located on the enclosed CD 6 Under the Profile button check if your PL9667 Q1 is displayed it Will be the first and see if your other PL9667 Q1 devices can be seen If you can see other devices under the Profile screen...

Page 10: ...DMA supported in the future Network Interface One port 10 100 Mbps Ethernet RJ 45 PHY Rates Up to 200 Mbps Distance Over 300 Meter Operating Frequency 2 to 30 MHz Modulation Schemes Orthogonal Frequency Division Multiplexing OFDM QAM 1024 256 64 16 QPSK BPSK EMI and Safety FCC Part 15 Class B UL US and Canada CE Additional Protocols Forward Error Correction FEC Automatic Channel Adaptation Power S...

Page 11: ... 45 C for EU plug Operating temperature 32 F to 95 F 0 C to 35 C for US plug Operating humidity 10 to 85 Non condensing Storage temperature 4 F to 158 F 20 C to 70 C Storage humidity 5 to 90 Non condensing Quality of Service ToS 802 1q TDMA supported in the future Warranty lifetime ...

Page 12: ...12 of 21 Components Front Panel Use the status lights on the front panel to verify connections ...

Page 13: ... Low connection Good connection Excellent connection No connection Eth Link Illuminated Blinking Off Ethernet connectivity Ethernet traffic No Ethernet connectivity Bottom Panel The bottom panel of the PL9667 Q1 contains the following components l RJ 45 Ethernet port The label on the rear panel of the PlugLink HD AV Pass Thriugh Adapter contains the information listed below l MAC address l Model n...

Page 14: ......

Page 15: ...ORTANT If the POWER light is not blinking green repeat Step a until the power light is blinking green c This unit is now ready to join the existing HD AV network This unit will remain in this adder mode for about 2 minutes 2 From your existing devices either device A or device B press the SECURITY button BRIEFLY 1 second then release The POWER light should now be blinking green d IMPORTANT If the ...

Page 16: ...irst reset the unit back to its factory defaults by pressing the Firmware Default Reset FW RST button for 1 second then follow the procedure above The use of the SECURITY Network ID button is optional You may also use the application software described in the manual to set NEK s as well ...

Page 17: ...uct to an Asoka designated repair facility with shipping charge prepaid and b provide Asoka with proof of the original date of purchase Repaired or replacement products will be returned to you with shipping charges prepaid Asoka warrants any replaced or repaired product or component for the life of the product This warranty extends only to you the original purchaser and is not transferable to any ...

Page 18: ...ION OR THE PRODUCT EXCEPT AS SPECIFICALLY PROVIDED IN THIS AGREEMENT OR AS REQUIRED BY LAW THE WARRANTIES AND REMEDIES STATED ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHERS ORAL OR WRITTEN EXPRESS OR IMPLIED ANY AND ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT OF THIRD PARTY RIGHTS ARE EXPRESSLY EXCLUDED ASOKA SHALL NOT B...

Page 19: ...ment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct The interference by one or more of the following measures l Reorient or relocate the receiving antenna l Increase the separation between the equipment and receiver l Connect the equipment into an outlet on a circuit different fro...

Page 20: ...vironment This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment such modifications could void the user s authority to operate this equipment ...

Page 21: ...Asoka USA Corporation 2620 Augustine Drive Suite 230 Santa Clara CA 95054 USA USA Phone 408 550 8167 Fax 408 884 2390 www asokatech com 66 0384 01Rev 001 21 of 21 ...

Reviews: