Fan Replacement
312361L
15
Fan Replacement
Removal
1.
Relieve Pressure, page 5. Disconnect power cord
from outlet.
2.
Hi-Boy Models Only - Disconnect high-pressure
hose at pump outlet (see page 11).
3.
Remove two screws (4) and shroud (12).
4.
Remove spring clip (57b) on back of motor.
5.
Pull off fan (57a).
Installation
1.
Slide new fan (57a) in place on back of motor. Be
sure blades of fan face motor as shown.
2.
Install spring clip (57b).
3.
Replace shroud (12) and two screws (4).
4.
Hi-Boy Models Only - Connect high-pressure hose
at pump outlet (see page 12).
57b
57a
4
12
ti12422a