background image

PRO SERIES

USER MANUAL

FOR THE

PS 4379

FOUR CHANNEL LOUDSPEAKER MASTER STATION

 

CONTENTS 

1.0

SAFETY INSTRUCTIONS…………………………….….......3

2.0

GENERAL DESCRIPTION ..............................................4

3.0

UNPACKING .....................................................................4

4.0

MECHANICAL INSTALLATION...........................................4

5.0

MAINS POWER...................................................................5

6.0

FRONT PANEL CONTROLS...........................................6-9

7.0

REAR PANEL CONTROLS..........................................10-11

8.0

INTERNAL CONTROLS...............................................12-14

9.0

MODES..............................................................................15

10.0

CABLING...........................................................................16

11.0

PARTY LINE, TECHNICAL CONCEPT.............................17

12.0

WARRANTY......................................................................17

13.0

TECHNICAL SPECIFICATIONS.......................................17

14.0

DESIGN CRITERIA...........................................................18

Summary of Contents for PS 4379

Page 1: ...0 GENERAL DESCRIPTION 4 3 0 UNPACKING 4 4 0 MECHANICAL INSTALLATION 4 5 0 MAINS POWER 5 6 0 FRONT PANEL CONTROLS 6 9 7 0 REAR PANEL CONTROLS 10 11 8 0 INTERNAL CONTROLS 12 14 9 0 MODES 15 10 0 CABLIN...

Page 2: ...2 User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands...

Page 3: ...wider than the other This plug will fit only one way into the power outlet This is a safety feature If you are unable to insert the plug fully into the outlet try reversing the plug If the plug still...

Page 4: ...sound signal A short push of the CALL button will make the LED flash The Call sound signal buzzer will be activated when holding the button for two seconds In case the sound signal is un desirable all...

Page 5: ...tor which is provi ded to satisfy required local standards WARNING This appliance must be earthed 5 1 POWERING UP Powering up procedure Make sure that the power switch at the back of the unit is OFF C...

Page 6: ...ute on this channel After the CALL button is released the LEDS will continue to flash for further 2 seconds 4 TALK to ALL When the TALK to ALL button is pressed and held one will talk to all intercom...

Page 7: ...ch channel control the rejection in the high frequency range It compensates the capacity of the interconnecting cables It prevents the speaker from feeding back into the gooseneck microphone unit feed...

Page 8: ...this button all buzzers of the connected stations and of the PS 4379 can be muted The buzzers stay muted until the ALL BUZZERMUTE button is switched off again 14 HEADSET connector A XLR 4 type connect...

Page 9: ...mutes can be locked by pushing a small pin into the SETUP lock It will be unlocked by pushing it again When pushing and holding the set up lock the light intensity of the LEDs of the MIC MUTE BUZZER M...

Page 10: ...orm a 10 or 12 channel unit When linked 1 station will be the master with an active speaker and goose neck electret microphone The speaker and micro phone of the other unit will be switched off The CA...

Page 11: ...the external speaker 40 DC POWER INPUT These two connectors allow an external 12 28V DC 5A input as a back up for the internal mains power supply or should no 110 240 V mains supply be available 41 PO...

Page 12: ...annel C factory setting off Same as for No 4 No 2 CALL RECEIVE Channel B factory setting off Same as for No 4 No 1 CALL RECEIVE Channel A factory setting off Same as for No 4 DIP SWITCH BLOCK A No 6 P...

Page 13: ...e dip switch is in off position the mic mute signals of the connected intercom system will be routed to the outputs of the PS 4379 If the dip switch is in on position the Mic Mute signals of the conne...

Page 14: ...d in case of binaural use 44 PGM ROUTING JUMPERS With these two jumpers you can determine for binaural applications how the PGM signal is controlled and where it is to be sent to 8 0 INTERNAL CONTROLS...

Page 15: ...ode This mode is used for one way communication to dressing rooms etc and can be 1 person to many An AUX signal can be sent to paging receivers of which users can adjust their own listen volume When t...

Page 16: ...the shield of the cable which functions as the common return for audio and power Since the audio signal is transferred in an unbalanced way certain rules have to be obeyed when installing the cables o...

Page 17: ...urchase Faults arising from misuse unauthorised modifications or accidents are not covered by this warranty If the unit is faulty it should be sent in it s original packing to the supplier or your loc...

Page 18: ...base of low impedance signal transport User stations and power supplies are to be connected via low capacity cabling with an overall screen also see Cabling section Therefore HF signals are adequately...

Page 19: ...User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands 19...

Page 20: ...20 User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands...

Page 21: ...User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands...

Page 22: ...User Manual PS 4379 Issue 1 2007 ASL Intercom Utrecht The Netherlands...