![ASIX AX58200 User Manual Download Page 68](http://html.mh-extra.com/html/asix/ax58200/ax58200_user-manual_2982932068.webp)
68
Copyright (C) 2020-2021 Reserved by ASIX Electronics Corporation, All Rights Reserved.
AX58200
Motor Control User Guide
Reference Design User Guide
(CSP mode is supported in this
FW verson)
0x1A02
RECORD
Tx pdo mapping of csv
PDO Mapping
RO
Mapped objects:
status word
actual position
0x1C12
VAR
SM2 assignment
UNSIGNED16
RW
Assign by default the csp process
data mapping
0x1C13
VAR
SM3 assignment
UNSIGNED16
RW
Assign by default the csp process
data mapping
Table 8 - 2
0x6000~0xFFFF area object definition
Index
Object
Type
Name
Data Type
Access Mappable
Remark
0x603F
VAR
Error code
UNSIGNED16
RO
N
0x6040
VAR
Control word
UNSIGNED16
RW
Y
0x6041
VAR
Status word
UNSIGNED16
RO
Y
0x604F
VAR
VL Ramp Function Time
UNSIGNED32
RW
N
0x605A
VAR
Quick stop option code
INTEGER16
RW
N
0x605B
VAR
Shutdown option code
INTEGER16
RW
N
0x605C
VAR
Disable operation option code
INTEGER16
RW
N
0x605E
VAR
Fault reaction option code
INTEGER16
RW
N
0x6060
VAR
Modes of operation
INTEGER16
RW
Y
0x6061
VAR
Modes of operation display
INTEGER16
RO
Y
0x6064
VAR
Position actual value
INTEGER32
RO
Y
0x606C
VAR
Velocity actual value
INTEGER32
RO
Y
0x6077
VAR
Torque actual value
INTEGER16
RO
N
0x607A
VAR
Target position
INTEGER32
RW
Y
0x607C
VAR
Home offset
INTEGER32
RW
N
0x607D
ARRAY
Software position limit
UNSIGNED32-
RW
N
0x6085
VAR
Quick stop deceleration
UNSIGNED32
RW
N
0x6098
VAR
Homing method
INTEGER8
RO
N
0x6099
RECORD
Homing speed
-
RW
N
0x609A
VAR
Homing acceleration
UNSIGNED32
RO
N
0x60C2
RECORD
Interpolation time period
-
RW
N
0x60E3
RECORD
Supported homing methods
-
RO
N
0x60FD
VAR
Digital Inputs
UNSIGNED32
RO
N
0x60FF
VAR
Target velocity
INTEGER32
RW
Y
0x6502
VAR
Supported drive modes
UNSIGNED32
RO
N
(CSP
、
PP
、
HM mode is
supported in this FW
verson)
0xF000
RECORD
Modular device profile
-
RO
N
0xF010
VAR
Module profile list
UNSIGNED32
RO
N
Table 8 - 3