76
Using the Web Server
–
Password
: Enter the password of the mobile
communication provider.
•
Click on the
Configure
button.
•
Now please follow all the steps described in section
and then proceed with the
steps below.
•
Still on the
Base Setup
page, make sure the
Connection
fields in the
Serial Port x
panes are all set to “None/Cable”
•
In the
Network 1
pane, choose “Modem Direct IP - Port E”
in the
Connection
field.
•
The base being necessarily a client, enter the information
(
Connect Now
,
Address
,
Port
) allowing it to connect to the
rover (the server) to which it is supposed to deliver
corrections. No
Login
or
Password
is needed in this case.
Enable
Connect Now
to allow the receiver to establish the
connection right after you have clicked on
Configure
.
•
In the
Differential Stream 1
pane, choose
Port
= “E - Modem”
as the output port delivering the generated differential
data. In the
Message
field, choose the type of differential
message provided through this port (ATOM, RTCM, CMR,
CMR+ or DBEN).
NOTE: The receiver has been designed to offer two
separate and independent differential data outputs. Each
one can output a specific type of differential message. If
only one output is used, select
Port
=“None” for the other
output.
•
Click on the
Configure
button to let the Web Server load all
your new parameters to the receiver. You have now
reached the end of the configuration phase.
Direct IP Via
Ethernet
•
First, click on the
Connections
>
Ethernet
submenu.
•
Set the following Ethernet parameters to allow the receiver
to access the network through its Ethernet port:
HDS800
RTK Corrections
Ethernet
Users
IP address
or server name
Internet
(Client)
Summary of Contents for HDS800
Page 1: ...Reference Manual HDS800...
Page 16: ...x Enabling a Firmware Option 639 Decoding an NTRIP Source Table 639 Logging Raw Data 642...
Page 54: ...38 Receiver Description...
Page 104: ...88 Using the Web Server...
Page 189: ...173 Web Server Help Files Collection Configuration Tab...
Page 266: ...250 Using Serial Commands...
Page 606: ...590 Query Command Library...
Page 619: ...603 Data Output...
Page 628: ...612 Data Output...
Page 650: ...634 Troubleshooting...
Page 660: ...644 Other Procedures Memos...
Page 676: ...X XDR 110 112 587 Z Z Blade 1 ZDA 347 431 588...
Page 677: ......