283
Set Command Library
Query Command
$PASHQ,CPD,ARR,OFS
See Also
$PASHS,CPD,ARR,LEN
$PASHS,CPD,ARR,MOD
$PASHS,CPD,ARR,PAR
CPD,ARR,PAR: Setting Upper Limits in Heading Mode
Function
This command is used to set the upper limits of baseline
elevation and expected maximum error in the entered
baseline length.
Command Format
Syntax
$PASHS,CPD,ARR,PAR,d1[,f2][*cc]
Parameters
Example
Setting the limits to 10° for elevation and 0.02 m for baseline
length error:
$PASHS,CPD,ARR,PAR,10,0.02*3D
Relevant Query
Command
$PASHQ,CPD,ARR,PAR
See Also
$PASHS,CPD,ARR,LEN
$PASHS,CPD,ARR,MOD
$PASHS,CPD,ARR,OFS
Parameter
Description
Range
Default
d1
Maximum value of expected baseline
elevation (absolute value), in degrees.
Parameter d1 only affects the heading
operating mode and is not applied during
baseline length auto-calibration.
0° to 90°
15
f2
Maximum value of tolerated baseline
length error, in meters.
0.001 to
10.000
0.01
*cc
Optional checksum
*00-*FF
-
Summary of Contents for HDS800
Page 1: ...Reference Manual HDS800...
Page 16: ...x Enabling a Firmware Option 639 Decoding an NTRIP Source Table 639 Logging Raw Data 642...
Page 54: ...38 Receiver Description...
Page 104: ...88 Using the Web Server...
Page 189: ...173 Web Server Help Files Collection Configuration Tab...
Page 266: ...250 Using Serial Commands...
Page 606: ...590 Query Command Library...
Page 619: ...603 Data Output...
Page 628: ...612 Data Output...
Page 650: ...634 Troubleshooting...
Page 660: ...644 Other Procedures Memos...
Page 676: ...X XDR 110 112 587 Z Z Blade 1 ZDA 347 431 588...
Page 677: ......