Operating Manual - nX, nXe, and nXp Power Amplifiers
56
Protea DSP Specifications
(nXp models only)
Input Source Selection
Input Source Select Options . . . . .
Analog, Auto
(net, AES3, analog)
Dynamics
Brick Wall Limiter
Threshold
. . . . . . . . . . . . . . . . . . . -20dBu to +20dBu
Ratio . . . . . . . . . . . . . . . . . . . . . infinite
Attack
. . . . . . . . . . . . . . . . . . . . . 0.2ms/dB to 50 ms/dB
Release 5ms/dB to 1000ms/dB
Compressor
Threshold
. . . . . . . . . . . . . . . . . . . -20dBu to +20dBu
Ratio . . . . . . . . . . . . . . . . . . . . . 1.2:1 to infinite
Attack
. . . . . . . . . . . . . . . . . . . . . 0.2ms/dB to 50ms/dB
Release 5ms/dB to 1000ms/dB
Detector. . . . . . . . . . . . . . . . . . . . . Peak/Average
Attenuation Bus. . . . . . . . . . . . . . . 2 available
Metering . . . . . . . . . . . . . . . . . . . . In, Out, Attenuation,
superimpose on graph
Autoleveler
Target Level . . . . . . . . . . . . . . . . . -40dBu to +20dBu
Action
. . . . . . . . . . . . . . . . . . . . .
gentle, normal, aggressive,
user defined
Maximum Gain . . . . . . . . . . . . . . . 0dB to +22dB
Metering . . . . . . . . . . . . . . . . . . . . Input, Gain, Attenuation
Advanced Autoleveler
Controls
Ratio . . . . . . . . . . . . . . . . . . . . . 1.2:1 to 10:1
Threshold Below Target . . . . . . . . -30dB to 0dB
Gain Increase Rate . . . . . . . . . . . . 5ms/dB to 1000ms/dB
Gain Decrease Rate. . . . . . . . . . . . 5ms/dB to 1000ms/dB
Hold Time . . . . . . . . . . . . . . . . . . . 0-6s
Ambient Noise Compensation (Output Only)
Max Gain . . . . . . . . . . . . . . . . . . . -20dB to +20dB
Min/Base Gain . . . . . . . . . . . . . . . -40dB to +20dB
Gain Change Rate . . . . . . . . . . . . . 0.2s/dB to 20s/dB
Link Group . . . . . . . . . . . . . . . . . . 16 available
ANC Input Channel. . . . . . . . . . . . 1-2 or 1-4
Noise Threshold . . . . . . . . . . . . . . -40dBu to +20dBu
Program/Ambient Gain Ratio . . . . 0.3:1 to 3:1
Metering . . . . . . . . . . . . . . . . . . . . Input level, Attenuation,
Average noise
Ducker
Ducking Type . . . . . . . . . . . . . . . . high/low priority, trigger,
filibuster, ducked program
Trigger Threshold
. . . . . . . . . . . . . -80dBu to +20dBu
Ducking Release . . . . . . . . . . . . . . 5ms/dB to 1000ms/dB
Ducking Depth . . . . . . . . . . . . . . . 0dB to -30dB, -
∞
Enable Ducking at Matrix Mixer . Yes
Metering . . . . . . . . . . . . . . . . . . . . Input
Gate
Threshold
. . . . . . . . . . . . . . . . . . . -80dBu to +20dBu
Range . . . . . . . . . . . . . . . . . . . . . off, 100dB to 0dB
Attack
. . . . . . . . . . . . . . . . . . . . . 0.2ms/dB to 50ms/dB
Release 5ms/dB to 1000ms/dB
Metering . . . . . . . . . . . . . . . . . . . . Key Signal, Gate LED
superimpose on graph
Advanced
Gate Controls
Key Engage Enable. . . . . . . . . . . . Yes
Key Frequency . . . . . . . . . . . . . . . 20Hz to 20kHz
Key Bandwidth . . . . . . . . . . . . . . . 0.016 to 3.995 octave
Gain
Gain . . . . . . . . . . . . . . . . . . . . . . . . -50dB to +12dB, off,
polarity invert
Gain w/VCA. . . . . . . . . . . . . . . . . . -50dB to +12dB, off,
polarity invert
Digital VCA Groups . . . . . . . . . . . 4 available
Remote Gain
(Remote RD8C Level Control). . . Enable, Disable
Metering . . . . . . . . . . . . . . . . . . . . RD8C Active LED
WR-5 (neWR-5) Remote Gain . . . 0 to -50dB, Mute
Equalization
31 Band Graphic
Filter Type
. . . . . . . . . . . . . . . . . . constant or proportional Q
Bandwidth . . . . . . . . . . . . . . . . . . 0.499 to 0.25 octave
Cooling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Continuously variable temperature controlled axial fan(s)
Power Cable Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20A powerCON
®
(32A powerCON
®
on 3.04 model only)
Operating Voltage Range (50-60Hz, 85VAC or 170VAC minimum startup)
70-135VAC @110-120VAC, or 140-270VAC @220-240VAC
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32°F-120°F, (0°C-49°C) noncondensing
Unit Dimensions (all models) . . . . . . . . . . . . . . . . . . . . . . . . . . . .19”W x 3.5”H x 16.84”D (483 x 89 x 428mm)
Unit Weight by nX Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4002/8002 21.5lbs (9.75kg), 1.52/3.02 22.0lbs (10kg)
4004/8004 25.2lbs (11.4kg), 1.54/3.04 28.0lbs (12.7kg)
Shipping Dimensions (all models). . . . . . . . . . . . . . . . . . . . . . . . .24.5" x 22" x 5.25" (622mm x 559mm x 133mm)
Shipping Weight by nX Model . . . . . . . . . . . . . . . . . . . . . . . . . . .4002/8002 27.6lbs (12.5kg), 1.52/3.02 28.01lbs (12.8kg)
4004/8004 31.3lbs (14.2kg), 1.54/3.04 34.1lbs (15.5kg)
Safety/Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .cTUVus, CE, FCC Class B, RoHS