WOOD BURNING CIRCULATOR HEATER

MODELS EC95/BEC95

OMNI-TEST LABORATORIES, INC.

LISTED BY

PORTLAND

OREGON, USA

C

S

S

U

COMPANY

UN

ITE

D STATES STOV

E

United States Stove Company • 227 Industrial Park Road • P.O. Box 151 • South Pittsburg, TN 37380

SAFETY NOTICE:

If this heater is not properly installed, a house 

fi

 re may result.

For your safety, follow the installation directions.

Contact local building or 

fi

 re of

fi

 cials about restrictions and

inspection requirements in your area.

CAUTION:

Read all instructions carefully before starting the installation

or operation of this heater.

Improper installation may void your warranty.

DO NOT USE THIS HEATER IN A MOBILE HOME OR TRAILER

This unit was tested and listed to UL 1482-1996 by OMNI-Test Laboritories

Please read this entire manual before you install and use your new room heater. Failure to follow instructions 

may result in property damage, bodily injury, or even death.

website:  www.usstove.com

Installation, Operation and Maintenance Instructions

851394 D

Report #: 215-S-18-4

Summary of Contents for BEC95

Page 1: ...ials about restrictions and inspection requirements in your area CAUTION Read all instructions carefully before starting the installation or operation of this heater Improper installation may void you...

Page 2: ...PAIR PARTS 20 IMPORTANT SAFETY INFORMATION To assure that satisfactory and safe service is received from this heater 1 Read these instructions entirely before beginning any part of the installation 2...

Page 3: ...central heat outlets and inlets to reduce the chance of drafts blowing smoke ashes or sparks out of the heater during refueling or ash removal The heater should be located where a small supply of fue...

Page 4: ...4 EC95 FIGURE 3 MINIMUM CLEARANCES TO COMBUSTIBLES FIGURE 4 MINIMUM CLEARANCES TO COMBUSTIBLES SIDE SECTION VIEW PLAN SECTION VIEW...

Page 5: ...Park Quincy MA 02269 The Chimney connector pipe from heater to chimney must be 6 inches in diameter and made from 24 gauge or heavier steel The length of the chim ney connector and number of elbows u...

Page 6: ...hickness The sheet steel supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold the chimney section Fasteners used to secure chimney sections shall not pe...

Page 7: ...2 IN TO COMBUSTIBLES PART A FIGURE 7 FIGURE 7 CONTINUED ON NEXT PAGE There are basically two methods of metal prefabricated chimney installation One method is to install the chimney in side the reside...

Page 8: ...RY CHIMNEY CONSTRUCTED TO NFPA 211 SHEET STEEL SUPPORTS 24 GAUGE MIN THICKNESS CHIMNEY CONNECTOR TO HEATER MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN MINIMUM...

Page 9: ...away from the heater to avoid a fire If you chose to you may install the heater and chimney connector closer to combustible surfaces than indicated by Figures 1 through 4 if a clearance reduction sys...

Page 10: ...obtain the fireplace items called for by figure 4 3 If the heater is to be installed on a combustible floor purchase a listed noncombustible floor protector as described in this manual and install it...

Page 11: ...stat control knob to the Hi position See figure 9 Open the feed door see figure 10 and lay paper and kindling on the grate in sufficient quantities to ensure good ignition WARNING NEVER USE GASOLINE G...

Page 12: ...off and shortens the length of time the dense smoke is likely to deposit creosote on the chimney walls DO NOT TAMPER WITH THE INTERNAL THERMOSTAT MECHANISM The thermostat has been designed and calibr...

Page 13: ...for several days when embedded in ashes VENTING SYSTEM CHIMNEY CONNECTOR AND CHIMNEY The venting system consists of the heater s chimney connector the pipe which connects the heater to the chimney and...

Page 14: ...t has grown tall can affect the draft of a chimney that was previously trouble free and other factors The common unit used to measure draft is INCHES IF WATER To determine the draft of your chimney a...

Page 15: ...cleanly as possible Thus you should adjust the amount of wood you put in the heater to the outdoor temperature Placing excessive wood in the heater will cause excessive creosote formation in the chim...

Page 16: ...cifically designed for starting a fire The use of liquid fire starters can cause an explosion within the heater Do use only a Listed High Temperature Type HT Factory built Residential Type and Buildin...

Page 17: ...these and other similar materials can cause an explosion within the heater 4 Don t use an unlisted type B or poorly constructed or maintained chimney to vent this heater 5 Don t use galvanized pipe st...

Page 18: ...18 EC95 FIGURE 12 ILLUSTRATION OF REPAIR PARTS SEE LEDGER ON NEXT PAGE FOR PART NAMES AND PART NUMBERS...

Page 19: ...MBLY 1 34 69532 THERMOSTAT ASSEMBLY 1 45 89142 KNOB 1 M 89687 KNOB BLACK 46 851397 CONTROL PLATE 1 M 851728 CONTROL PLATE BLACK 47 24849 ROD NUT KIT 1 48 69224GO TRIM AND SCREEN ASSEMBLY 1 49 24851 LE...

Page 20: ...ce EC95 BEC95 Owner s Manual When writing always give the full model number which is on the nameplate at tached to the fireplace When ordering repair parts or options always give the following informa...